Annalen der Physik

The Bell‐Bloom‐Type Optically‐Pumped FID Rubidium Atomic Magnetometer With a Multi‐Passing Probe Beam and Two Counter‐Propagating Pump Beams

Yongbiao Yang, Zhengyu Su, Yang Li, Yanhua Wang, Jun He, Xiaojun Jia, Junmin Wang

Published Jul 1, 2026• 1 citation
Publisher

Abstract

ABSTRACT The Bell‐Bloom‐type optically‐pumped atomic magnetometers are well‐suited for weak geomagnetic field detection. However, conventional single‐beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy and sensitivity. To address this issue, this paper proposes and experimentally demonstrates a Bell‐Bloom‐type rubidium FID magnetometer scheme integrating orthogonally polarized counter‐propagating pumping and multi‐pass probe detection. This design homogenizes the atomic spin polarization distribution and suppresses light shifts and power broadening. This uniform polarization, in turn, allows the five‐pass probe configuration to achieve a significantly larger signal amplitude. Experimental results reveal that, compared with the traditional single‐beam pumping and single‐pass detection scheme, the proposed magnetometer achieves a remarkable improvement in magnetic field measurement accuracy, and the magnetic field sensitivity is improved from 18.9 to 3.1 pT/. Notably, the two techniques work synergistically, yielding a 6.1‐fold sensitivity enhancement that far exceeds their individual gains. This work provides an effective technical approach and reference for optimizing the performance of atomic magnetometers and their applications in precision measurement fields.

DOI
10.1002/andp.70254

Related papers

The Bell-Bloom-type optically-pumped FID Rubidium atomic magnetometer with a multi-passing probe beam and two counter-propagating pump beams

Yongbiao Yang, Zhengyu Su, Yang Li +4 more

The Bell-Bloom-type optically pumped atomic magnetometers are well suited for weak geomagnetic field detection. However, conventional single-beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy and sensitivity. To address this issue, this paper proposes and experimentally demonstrates a Bell-Bloom-type rubidium FID magnetometer scheme integrating orthogonally polarized counter-propagating pumping and multi-pass probe detection. This design homogenizes the atomic spin polarization distribution and suppresses light shifts and power broadening effects induced by the pump beam. Meanwhile, the five-pass probe configuration significantly enhances the signal amplitude. Experimental results reveal that, compared with the traditional single-beam pumping and single-pass detection scheme, the proposed magnetometer achieves a remarkable improvement in magnetic field measurement accuracy, and the magnetic field sensitivity is improved from 18.9 pT/\sqrt{Hz} to 3.1 pT/\sqrt{Hz}. This work provides an effective technical approach and reference for optimizing the performance of atomic magnetometers and extending their applications in integrated arrays.

arXiv:2604.02865•Apr 3, 2026•0 citations

Polarization‐Improved Bidirectional‐Pump Atomic Magnetometer Based on Spin‐Decoupled Metasurface

Shuo Sun, Jiahao Zhang, Rongtong Zhu +4 more

Abstract The optically pumped atomic magnetometer (OPAM) has emerged as an advanced instrument for magnetic field detection. However, the performance of conventional OPAMs is constrained by factors such as non‐uniform atomic polarization and insufficient precision in system polarization control. In this study, a bidirectional‐pump OPAM based on spin‐decoupled metasurface is presented and experimentally demonstrated. By designing a metasurface structure with a predefined phase distribution, the system generates two circularly polarized (CP) lights with distinct chirality and one linearly polarized (LP) light. Two beams of the CP light are directed in opposite directions along both sides of the cell, which effectively mitigates the polarization gradient within the cell and enhances the stability of the system. Additionally, the use of zero‐order LP light as the probe light for the system enhances energy utilization efficiency while simplifying the system architecture. The experimental results demonstrate that the OPAM based on metasurface successfully realizes precise control of atomic spin polarization. The proposed OPAM is capable of performing high‐precision magnetic field measurements, and the sensitivity has been improved to 1.85 pT/Hz 1/2 . This research not only advances the application of metasurfaces in quantum precision measurement but also offers a novel approach for enhancing the performance of atomic magnetometers.

Advanced Science•Jul 6, 2025•32 citations

Faraday-rotation Bell–Bloom atomic magnetometer using an alternating pump–probe beam

Songsong Li, Yi Zhang, Yuan Tian +2 more

We propose a scheme for a Bell–Bloom atomic magnetometer based on a single beam. In our approach, the light is periodically modulated synchronously with Larmor precession. As a result, the light that interacts with atoms is alternately polychromatic and monochromatic. When the light is polychromatic, the ±1st sidebands of the light are optically resonant with the atoms, and the atoms are polarized by pumping. When the light is monochromatic, a differential detection technique extracts the Faraday-rotation signal of the light, and the polarization of the light is probed. We demonstrate an experimental implementation of the Bell–Bloom magnetometer that achieves a sensitivity for magnetic-field detection of 0.25 pT/Hz1/2 at 1 Hz. Our scheme is suitable for developing compact, miniaturized magnetometers.

Journal of Applied Physics•Aug 25, 2021•16 citations

A Multi-Pass Optically Pumped Rubidium Atomic Magnetometer with Free Induction Decay

Lulu Zhang, Yongbiao Yang, Ni Zhao +2 more

A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.

arXiv:2301.08437•Sensors•Oct 7, 2022•18 citations

Reflection‐Compensated Orthogonal Non‐Overlapping Uniform Pumping Scheme For Triaxial Serf Atomic Magnetometers

Ying Liu, M.K. Song, Binyue Huang +4 more

ABSTRACT Triaxial spin‐exchange relaxation‐free (SERF) atomic magnetometer has attracted widespread attention for its capability of measuring the total magnetic field vector information. In this paper, we propose a triaxial SERF atomic magnetometer through orthogonal non‐overlapping pumping beam with improved atom spin polarization spatial uniformity by using a uniformized pump beam and reflection compensation . The homogenized beams are adopted to achieve uniform transverse polarization, while double‐pass reflection compensation is integrated to realize uniform longitudinal polarization. The polarizability distribution based on an effective optical path‐length formalism was obtained via theoretical simulation. The bandwidth, dispersion curves, stability, and sensitivity were experimentally analyzed under three configurations: uniformized pump beam , gaussian pump beam‐reflection compensation , and uniformized pump beam‐reflection compensation . Results of experiments reveal that the proposed configuration enhances three‐axis bandwidth by roughly 10 and improves X, Y, and Z sensitivities by approximately 35, 60, and 30, respectively, achieving sensitivities of 20.56 fT/(X), 30.75 fT/(Y) and 20.54 fT/(Z) at 140 and 2 mW. These results demonstrate a structurally simple yet highly effective approach for achieving high uniformity and stability in three‐axis vector magnetic sensing, with strong potential for applications such as spatial magnetic‐field mapping and bio‐magnetic measurement research.

Advanced Quantum Technologies•Jul 1, 2026•0 citations

Optimal Magneto‐Optical Angle in Single‐Beam Optically Pumped Atomic Magnetometers Considering the Spatial Distribution of Spin Polarization

Yuntian Zou, Chi Fang, Jiali Liu +7 more

ABSTRACT Single‐beam optically pumped atomic magnetometers (OPAMs) are promising tools for biomagnetic measurements in nonzero‐field environments owing to their high sensitivity and compactness. However, the angle between the external bias magnetic field and the pump light affects the spin polarization of the atomic ensemble, thereby influencing the magnetometer performance and making the optimization of the magneto‐optical angle essential. In this study, a spatially resolved steady‐state spin polarization model incorporating the magneto‐optical angle is established for the first time, and an analytical expression of the spin precession signal under RF magnetic field excitation is derived. It is demonstrated that an optimal angle exists at which the magnetometer exhibits the maximum response and the highest sensitivity, which is experimentally determined to be 26° in our single‐beam OPAM. At this angle, the combined influence of the steady‐state spin polarization, spin precession projection, transmitted light intensity, and transverse spin relaxation reaches an optimal overall state, leading to a 14% enhancement in sensitivity and a 32% reduction in detection noise compared with the conventional 45° configuration. These findings provide guidance for optimizing the experimental parameters of single‐beam OPAMs for weak magnetic signal detection in nonzero‐field environments.

Advanced Quantum Technologies•Jan 1, 2026•1 citation
ABSTRACT The Bell‐Bloom‐type optically‐pumped atomic magnetometers are well‐suited for weak geomagnetic field detection. However, conventional single‐beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy and sensitivity. To address this issue, this paper proposes and experimentally demonstrates a Bell‐Bloom‐type rubidium FID magnetometer scheme integrating orthogonally polarized counter‐propagating pumping and multi‐pass probe detection. This design homogenizes the atomic spin polarization distribution and suppresses light shifts and power broadening. This uniform polarization, in turn, allows the five‐pass probe configuration to achieve a significantly larger signal amplitude. Experimental results reveal that, compared with the traditional single‐beam pumping and single‐pass detection scheme, the proposed magnetometer achieves a remarkable improvement in magnetic field measurement accuracy, and the magnetic field sensitivity is improved from 18.9 to 3.1 pT/. Notably, the two techniques work synergistically, yielding a 6.1‐fold sensitivity enhancement that far exceeds their individual gains. This work provides an effective technical approach and reference for optimizing the performance of atomic magnetometers and their applications in precision measurement fields.
The Bell-Bloom-type optically pumped atomic magnetometers are well suited for weak geomagnetic field detection. However, conventional single-beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy and sensitivity. To address this issue, this paper proposes and experimentally demonstrates a Bell-Bloom-type rubidium FID magnetometer scheme integrating orthogonally polarized counter-propagating pumping and multi-pass probe detection. This design homogenizes the atomic spin polarization distribution and suppresses light shifts and power broadening effects induced by the pump beam. Meanwhile, the five-pass probe configuration significantly enhances the signal amplitude. Experimental results reveal that, compared with the traditional single-beam pumping and single-pass detection scheme, the proposed magnetometer achieves a remarkable improvement in magnetic field measurement accuracy, and the magnetic field sensitivity is improved from 18.9 pT/\sqrt{Hz} to 3.1 pT/\sqrt{Hz}. This work provides an effective technical approach and reference for optimizing the performance of atomic magnetometers and extending their applications in integrated arrays.
Abstract The optically pumped atomic magnetometer (OPAM) has emerged as an advanced instrument for magnetic field detection. However, the performance of conventional OPAMs is constrained by factors such as non‐uniform atomic polarization and insufficient precision in system polarization control. In this study, a bidirectional‐pump OPAM based on spin‐decoupled metasurface is presented and experimentally demonstrated. By designing a metasurface structure with a predefined phase distribution, the system generates two circularly polarized (CP) lights with distinct chirality and one linearly polarized (LP) light. Two beams of the CP light are directed in opposite directions along both sides of the cell, which effectively mitigates the polarization gradient within the cell and enhances the stability of the system. Additionally, the use of zero‐order LP light as the probe light for the system enhances energy utilization efficiency while simplifying the system architecture. The experimental results demonstrate that the OPAM based on metasurface successfully realizes precise control of atomic spin polarization. The proposed OPAM is capable of performing high‐precision magnetic field measurements, and the sensitivity has been improved to 1.85 pT/Hz 1/2 . This research not only advances the application of metasurfaces in quantum precision measurement but also offers a novel approach for enhancing the performance of atomic magnetometers.
We propose a scheme for a Bell–Bloom atomic magnetometer based on a single beam. In our approach, the light is periodically modulated synchronously with Larmor precession. As a result, the light that interacts with atoms is alternately polychromatic and monochromatic. When the light is polychromatic, the ±1st sidebands of the light are optically resonant with the atoms, and the atoms are polarized by pumping. When the light is monochromatic, a differential detection technique extracts the Faraday-rotation signal of the light, and the polarization of the light is probed. We demonstrate an experimental implementation of the Bell–Bloom magnetometer that achieves a sensitivity for magnetic-field detection of 0.25 pT/Hz1/2 at 1 Hz. Our scheme is suitable for developing compact, miniaturized magnetometers.
A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.
ABSTRACT Triaxial spin‐exchange relaxation‐free (SERF) atomic magnetometer has attracted widespread attention for its capability of measuring the total magnetic field vector information. In this paper, we propose a triaxial SERF atomic magnetometer through orthogonal non‐overlapping pumping beam with improved atom spin polarization spatial uniformity by using a uniformized pump beam and reflection compensation . The homogenized beams are adopted to achieve uniform transverse polarization, while double‐pass reflection compensation is integrated to realize uniform longitudinal polarization. The polarizability distribution based on an effective optical path‐length formalism was obtained via theoretical simulation. The bandwidth, dispersion curves, stability, and sensitivity were experimentally analyzed under three configurations: uniformized pump beam , gaussian pump beam‐reflection compensation , and uniformized pump beam‐reflection compensation . Results of experiments reveal that the proposed configuration enhances three‐axis bandwidth by roughly 10 and improves X, Y, and Z sensitivities by approximately 35, 60, and 30, respectively, achieving sensitivities of 20.56 fT/(X), 30.75 fT/(Y) and 20.54 fT/(Z) at 140 and 2 mW. These results demonstrate a structurally simple yet highly effective approach for achieving high uniformity and stability in three‐axis vector magnetic sensing, with strong potential for applications such as spatial magnetic‐field mapping and bio‐magnetic measurement research.
ABSTRACT Single‐beam optically pumped atomic magnetometers (OPAMs) are promising tools for biomagnetic measurements in nonzero‐field environments owing to their high sensitivity and compactness. However, the angle between the external bias magnetic field and the pump light affects the spin polarization of the atomic ensemble, thereby influencing the magnetometer performance and making the optimization of the magneto‐optical angle essential. In this study, a spatially resolved steady‐state spin polarization model incorporating the magneto‐optical angle is established for the first time, and an analytical expression of the spin precession signal under RF magnetic field excitation is derived. It is demonstrated that an optimal angle exists at which the magnetometer exhibits the maximum response and the highest sensitivity, which is experimentally determined to be 26° in our single‐beam OPAM. At this angle, the combined influence of the steady‐state spin polarization, spin precession projection, transmitted light intensity, and transverse spin relaxation reaches an optimal overall state, leading to a 14% enhancement in sensitivity and a 32% reduction in detection noise compared with the conventional 45° configuration. These findings provide guidance for optimizing the experimental parameters of single‐beam OPAMs for weak magnetic signal detection in nonzero‐field environments.