Optical atomic clocks have been rapidly developing in recent decades, resulting in major improvements in both precision and accuracy. As a result, they have become instrumental in multiple areas of applied and fundamental research. Despite all atomic frequency references having more than two energy-levels, the commonly used model for evaluating their ultimate limits assumes a two-level atom. This leads to frequency interrogation protocols and theoretical stability bounds that are suboptimal for a true multi-level atom. The most fundamental stability bound assumes two noise sources - quantum projection noise and spontaneous decay from the excited state. In this work, we analyze a model that includes these noise types and is generalized beyond the two-level assumption, where spontaneous decay can branch to more than a single ground state. This model allows for detection and exclusion of atomic frequency interrogations in which the atom decayed, leading to a frequency stability improvement of up to $\approx 4.5 \text{ dB}$ compared with the two-level model. Furthermore, we identify an even greater stability enhancement of $\approx 5.4 \text{ dB}$ for frequency comparisons between atoms in an odd parity Bell state. These enhancements are particularly relevant for the numerous trapped-ion optical clock species that operate close to lifetime-limited stability. We calculate new stability limits for those cases and provide a detailed experimental protocol for frequency interrogation with an $^{27}\text{Al}^{+}$ optical ion clock.
Optical atomic clocks have been rapidly developing in recent decades, resulting in major improvements in both precision and accuracy. As a result, they have become instrumental in multiple areas of applied and fundamental research. Despite all atomic frequency references having more than two energy-levels, the commonly used model for evaluating their ultimate limits assumes a two-level atom. This leads to frequency interrogation protocols and theoretical stability bounds that are suboptimal for a true multi-level atom. The most fundamental stability bound assumes two noise sources - quantum projection noise and spontaneous decay from the excited state. In this work, we analyze a model that includes these noise types and is generalized beyond the two-level assumption, where spontaneous decay can branch to more than a single ground state. This model allows for detection and exclusion of atomic frequency interrogations in which the atom decayed, leading to a frequency stability improvement of up to ≈4.5 dB compared with the two-level model. Furthermore, we identify an even greater stability enhancement of ≈5.4 dB for frequency comparisons between atoms in an odd parity Bell state. These enhancements are particularly relevant for the numerous trapped-ion optical clock species that operate close to lifetime-limited stability. We calculate new stability limits for those cases and provide a detailed experimental protocol for frequency interrogation with an 27Al+ optical ion clock.
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.
Optical atomic clocks are a driving force for precision measurements due to the high accuracy and stability demonstrated in recent years. While further improvements to the stability have been envisioned by using entangled atoms, squeezing the quantum mechanical projection noise, evaluating the overall gain must incorporate essential features of an atomic clock. Here, we investigate the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we report here quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in good agreement with numerical simulations of the closed servo-loop. We find that for usual cyclic Ramsey interrogation of single atomic ensembles with dead time, even with the current most stable lasers spin squeezing can only improve the clock stability for ensembles below a critical atom number of about one thousand in an optical Sr lattice clock. Even with a future improvement of the laser performance by one order of magnitude the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers.
Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.
Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1×10^{-18} for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.
In the mid-20th century, atoms were realized to be good candidates for time or frequency standards since transition energies or frequencies between two energy levels of some unperturbed atoms are more stable than those defined by the rotation of the earth or artefact-based clocks such as quartz crystal clocks. This motivated extensive research on realization and improvement of such kind of quantum-based time or frequency standards. The ultra-stable laser, referred to as a local oscillator in a clock, still drifts over time due to environmentally induced length fluctuations of the reference cavity. With the development of ion traps, ultra-narrow linewidth lasers and optical frequency combs, optical clocks based on single trapped ions as a new type of clocks have been realized in many laboratories. Ions can only stay in the trap within a certain region, which is called stability region. There is a variety of potential sources of systematic shifts associated with the clock transition in ion optical clocks.