In the mid-20th century, atoms were realized to be good candidates for time or frequency standards since transition energies or frequencies between two energy levels of some unperturbed atoms are more stable than those defined by the rotation of the earth or artefact-based clocks such as quartz crystal clocks. This motivated extensive research on realization and improvement of such kind of quantum-based time or frequency standards. The ultra-stable laser, referred to as a local oscillator in a clock, still drifts over time due to environmentally induced length fluctuations of the reference cavity. With the development of ion traps, ultra-narrow linewidth lasers and optical frequency combs, optical clocks based on single trapped ions as a new type of clocks have been realized in many laboratories. Ions can only stay in the trap within a certain region, which is called stability region. There is a variety of potential sources of systematic shifts associated with the clock transition in ion optical clocks.
In the mid-20th century, atoms were realized to be good candidates for time or frequency standards since transition energies or frequencies between two energy levels of some unperturbed atoms are more stable than those defined by the rotation of the earth or artefact-based clocks such as quartz crystal clocks. This motivated extensive research on realization and improvement of such kind of quantum-based time or frequency standards. The ultra-stable laser, referred to as a local oscillator in a clock, still drifts over time due to environmentally induced length fluctuations of the reference cavity. With the development of ion traps, ultra-narrow linewidth lasers and optical frequency combs, optical clocks based on single trapped ions as a new type of clocks have been realized in many laboratories. Ions can only stay in the trap within a certain region, which is called stability region. There is a variety of potential sources of systematic shifts associated with the clock transition in ion optical clocks.
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.
Transitions between discrete energy levels in well-isolated atomic systems are highly reproducible and therefore make ideal references for highly accurate frequency standards or clocks. In particular, a single laser-cooled ion confined in a radiofrequency ion trap closely approximates the spectroscopic ideal of a particle at rest in a perturbation-free environment. Narrow optical transitions in such systems are therefore very promising for the realization of optical clocks with accuracy around 2 orders of magnitude higher than current microwave primary standards. In this paper the fundamental aspects, current performance and applications of trapped ion optical clocks are reviewed and the potential for future improvements is considered.
Abstract The atomic clocks, whether operating at optical or microwave region, can be divided into two categories according to their working mode, namely the passive clocks and active clocks. The passive clocks, whose standard frequency is locked to an ultra-narrow atomic spectral line, such as laser cooled Cs beam or lattice trapped Sr atoms, depend on the spontaneous emission line. On the contrary, the active clocks, in which the atoms are used as the gain medium, are based on the stimulated emission radiation, their spectrum can be directly used as the frequency standard. Up to now, the active hydrogen maser has been the most stable microwave atomic clocks. Also, the Sr superradiant active atomic clock is prospects for a millihertz-linewidth laser. Moreover, the optical clocks are expected to surpass the performance of microwave clocks both in stability and uncertainty, since their higher working frequency. The active optical clock has the potential to improve the stability of the best clocks by 2 orders of magnitude. In this work, we introduce the development of active optical clocks, and their types is classified according to the energy-level structure of atoms for stimulated radiation.
Ultra stable frequency references such as the ones used in optical atomic clocks and for quantum metrology may be obtained by stabilizing a laser to an optical cavity that is stable over time. State-of-the-art frequency references are constructed in this way, but their stabilities are currently limited by thermally induced length fluctuations in the reference cavity. Several alternative approaches using the potential for frequency discriminating of highly forbidden narrow atomic transitions have been proposed in, e.g., [1] and [2]. In this proceeding we will present some of the ongoing experimental efforts derived from these proposals, to use cavity-enhanced interaction with atomic 88 Sr samples as a frequency reference for laser stabilization. Such systems can be realized using both passive and active approaches where either the atomic phase response is used as an error signal, or the narrow atomic transition itself is used as a source for a spectrally pure laser. Both approaches shows the promise of being able to compete with the current state of the art in stable lasers and have similar limitations on their ultimately achievable linewidths [1, 2].
Research progress of Al+ ion optical frequency standard based on quantum logic technique
Optical atomic clocks have many applications in the definition of the time and the length, measurement of fundamental constants and their potential variations with time, testing of relativity, very long baseline interferometry, geodesy, and global navigation satellite systems. An optical clock consists of three parts: ultra-stable laser, frequency comb and trapped ions or atoms. The accuracy of optical atomic clocks can be affected by Doppler shift, Zeeman shift, Stark shift, collision shift, blackbody radiation (BBR) shift, etc. The BBR shift is very difficult to be characterized and controlled. Among all optical atomic clocks under current development, Al+ optical clock has the smallest BBR shift at a level of 4.0×10−19, therefore the Al+ is a promising ion for high-accuracy optical frequency standard. In this article we give a review on the three parts of optical frequency standards, the basic working principle of Al+ ion optical frequency standard based on quantum logic technique, and research progress of an Al+ optical clock under development at Huazhong University of Science and Technology.
The stability and accuracy of atomic microwave frequency standards (atomic clocks) have been improving at a rate exceeding one order of magnitude per decade for the past 30 years. This sustained improvement has been driven mainly by the many and diverse technological applications requiring highly stable and accurate time and frequency standards. There is no reason to suspect that this rate of progress is slowing. Over the last decade, research and development in atomic frequency standards has tended increasingly towards the use of atom and ion trapping technologies to approach the supposedly ideal unperturbed atomic frequency reference consisting of a single atom or ion either motionless or in free-fall in a perfect, field-free vacuum. This work has been facilitated by the relatively recent development of techniques whereby laser light is used to cool, confine and manipulate atoms or ions. This paper reviews the current status of atomic microwave frequency standards based on trapped atoms and trapped ions, and attempts to explain the motivation for their development and the principles of their operation, with particular emphasis on the physics of factors which limit their performance.