Abstract

Optical quantum computing, as well as quantum communication and sensing technology based on quantum correlations are in preparation. These require photodiodes for the detection of about 10^16 photons per second with close to perfect quantum efficiency. Already the radiometric calibration is a challenge. Here, we provide the theoretical description of the quantum radiometric calibration method. Its foundation is squeezed light and Heisenberg's uncertainty principle, making it an example of quantum metrology based on quantum correlations. Unlike all existing radiometric calibration methods, ours is in situ and provides both the detection efficiency and the more stringent quantum efficiency directly for the measurement frequencies of the user application. We calibrate a pair of the most efficient commercially available photodiode at 1550 nm to a system detection efficiency of (97.20 + 0.37)% using 10-dB-squeezed vacuum states. Our method has great potential for significantly higher precision and accuracy, but even with this measurement, we can clearly say that the available photodiode efficiencies for 1550 nm are unexpectedly low, too low for future gravitational wave detectors and for optical quantum computing.

Related papers

Absolute self-calibration of the quantum efficiency of single-photon detectors

Xihao Chen, Yanhua Zhai, Da Zhang +1 more

Single-photon detectors are finding increasingly wide application in all branches of science and technology thus a precise knowledge of their quantum efficiency is an essential prerequisite. We have performed the first proof-of-principle demonstration of a means to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is based on the time correlation of entangled photons pairs emitted in spontaneous parametric down conversion. The measured quantum efficiency of a Si avalanche photodiode single-photon detector agrees well with the product specifications.

Optics Letters•Jul 25, 2006•21 citations

Absolute self-calib ration of single-photon detectors with cw and pulsed spontaneous parametric down-conversion - art. no. 630505

La Wu, Xiangdong Chen, YH Zhai +2 more

Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.

•Jan 1, 2006•0 citations

Absolute self-calibration of single-photon detectors with cw and pulsed spontaneous parametric down-conversion

Ling-An Wu, Xi-Hao Chen, Yanhua Zhai +2 more

Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 31, 2006•0 citations

Radiometric applications of correlated photon metrology

Jessica Y. Cheung, Christopher J. Chunnilall, Jian Wang

Many of the schemes utilizing photon states under investigation for Quantum Information Processing (QIP) technology involve active and passive optical components. In order to be able to establish fidelity levels for these schemes, the performance of these optical components and their coupling efficiencies require careful and accurate characterization. Correlated photons, the basis of entangled photon states, offer a direct means of measuring detector quantum efficiency and source radiance in the photon counting regime. Detector and source calibration by correlated photon techniques therefore address some of the key factors critical to QIP technology and the developing techniques of correlated/entangled photon metrology. Work is being undertaken at NPL to establish the accuracy limitations of the correlated photon technique for detector and source calibration. This paper will report on investigations concerning the characterization of silicon avalanche photodiode detectors using the correlated photon technique.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 19, 2004•5 citations

Investigation of absolute measurement in quantum efficiency of photoelectric detectors by means of correlated photons

Yu Feng, Xiaobing Zheng, Yanli Qiao +1 more

There are two general methods for radiometric calibration of detectors. One is based on radiometric sources and the other is based on detectors. Because two methods need to establish primary standard of high precision and transfer chain of standard, the precision of standard will be reduced by extension of the chain. An absolute calibration of quantum efficiency of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal. Generation mechanism of SPDC is interpreted with theories of quantum mechanics and classical theories. The theory of calibration based correlated photons are demonstrated. The project for proof of principle of absolute calibration of quantum efficiency of radiometric detectors is given in this paper. Comparing with traditional methods, the advantages of it are pointed out. A scheme using to calibrate quantum efficiency of infrared detectors is described here. The measurement of spatial and spectral response of detectors is mentioned too.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 23, 2006•0 citations

Quantum-efficiency measurement of photodetectors based on entangled photons

Wei Zhang

The calibration of radiometric sensors is critical to ensure the accuracy of the remote sensing data and their usability.The current methods of the radiometric calibration are based on the establishment of high-precision primary standard and standard transfer chain,and the transfer chain is the main source of errors.The entangled photons-based theory creates a new technical way to realize the radiometric calibration of standardless transfer.The method of absolute calibration of photodetectors based on a nonclassical effect of the nonlinear optics in the photon-counting regime was discussed.The measurement was realized with the technique of entangled photons at 702 nm generated by a parametric down conversion process in a nonlinear crystal of BBO.The photomultiplier quantum-efficiency at the wavelength was measured during the experiment.It is estimated that the deviation is 0.1%.The technique is independent of any externally calibrated radiometric standards.

Journal of Applied Optics•Jan 1, 2007•0 citations
Optical quantum computing, as well as quantum communication and sensing technology based on quantum correlations are in preparation. These require photodiodes for the detection of about 10^16 photons per second with close to perfect quantum efficiency. Already the radiometric calibration is a challenge. Here, we provide the theoretical description of the quantum radiometric calibration method. Its foundation is squeezed light and Heisenberg's uncertainty principle, making it an example of quantum metrology based on quantum correlations. Unlike all existing radiometric calibration methods, ours is in situ and provides both the detection efficiency and the more stringent quantum efficiency directly for the measurement frequencies of the user application. We calibrate a pair of the most efficient commercially available photodiode at 1550 nm to a system detection efficiency of (97.20 + 0.37)% using 10-dB-squeezed vacuum states. Our method has great potential for significantly higher precision and accuracy, but even with this measurement, we can clearly say that the available photodiode efficiencies for 1550 nm are unexpectedly low, too low for future gravitational wave detectors and for optical quantum computing.
Single-photon detectors are finding increasingly wide application in all branches of science and technology thus a precise knowledge of their quantum efficiency is an essential prerequisite. We have performed the first proof-of-principle demonstration of a means to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is based on the time correlation of entangled photons pairs emitted in spontaneous parametric down conversion. The measured quantum efficiency of a Si avalanche photodiode single-photon detector agrees well with the product specifications.
Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.
Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.
Many of the schemes utilizing photon states under investigation for Quantum Information Processing (QIP) technology involve active and passive optical components. In order to be able to establish fidelity levels for these schemes, the performance of these optical components and their coupling efficiencies require careful and accurate characterization. Correlated photons, the basis of entangled photon states, offer a direct means of measuring detector quantum efficiency and source radiance in the photon counting regime. Detector and source calibration by correlated photon techniques therefore address some of the key factors critical to QIP technology and the developing techniques of correlated/entangled photon metrology. Work is being undertaken at NPL to establish the accuracy limitations of the correlated photon technique for detector and source calibration. This paper will report on investigations concerning the characterization of silicon avalanche photodiode detectors using the correlated photon technique.
There are two general methods for radiometric calibration of detectors. One is based on radiometric sources and the other is based on detectors. Because two methods need to establish primary standard of high precision and transfer chain of standard, the precision of standard will be reduced by extension of the chain. An absolute calibration of quantum efficiency of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal. Generation mechanism of SPDC is interpreted with theories of quantum mechanics and classical theories. The theory of calibration based correlated photons are demonstrated. The project for proof of principle of absolute calibration of quantum efficiency of radiometric detectors is given in this paper. Comparing with traditional methods, the advantages of it are pointed out. A scheme using to calibrate quantum efficiency of infrared detectors is described here. The measurement of spatial and spectral response of detectors is mentioned too.
The calibration of radiometric sensors is critical to ensure the accuracy of the remote sensing data and their usability.The current methods of the radiometric calibration are based on the establishment of high-precision primary standard and standard transfer chain,and the transfer chain is the main source of errors.The entangled photons-based theory creates a new technical way to realize the radiometric calibration of standardless transfer.The method of absolute calibration of photodetectors based on a nonclassical effect of the nonlinear optics in the photon-counting regime was discussed.The measurement was realized with the technique of entangled photons at 702 nm generated by a parametric down conversion process in a nonlinear crystal of BBO.The photomultiplier quantum-efficiency at the wavelength was measured during the experiment.It is estimated that the deviation is 0.1%.The technique is independent of any externally calibrated radiometric standards.