arXiv:2501.08870 · Methods in microscopy

Benchmarking of fluorescence lifetime measurements using time-frequency correlated photons

Tobias Bernd Gäbler, Patrick Then, Christian Eggeling, Markus Gräfe, Nitish Jain, Valerio Flavio Gili

Published Mar 10, 2025• 3 citations
arXivHTMLPDF

Abstract

Abstract The investigation of fluorescence lifetime became an important tool in biology and medical science. So far, established methods of fluorescence lifetime measurements require the illumination of the investigated probes with pulsed or amplitude-modulated light. In this paper, we examine the limitations of an innovative method of fluorescence lifetime using the strong time-frequency correlation of entangled photons generated by a continuous-wave source. For this purpose, we investigate the lifetime of IR-140 to demonstrate the functional principle and its dependencies on different experimental parameters. We also compare this technique with state-of-the-art FLIM and observed an improved figure-of-merit. Finally, we discuss the potential of a quantum advantage.

DOI
10.1515/mim-2025-0001

Related papers

Entangled Photon Correlations Allow a Continuous-Wave Laser Diode to Measure Single-Photon, Time-Resolved Fluorescence

Nathan Harper, Bryce P. Hickam, Manni He +1 more

Fluorescence lifetime experiments are a standard approach for measuring excited-state dynamics and local environmental effects. Here, we show that entangled photon pairs produced from a continuous-wave (CW) laser diode can replicate pulsed laser experiments without phase modulation. As a proof of principle, picosecond fluorescence lifetimes of indocyanine green are measured in multiple environments. The use of entangled photons has three unique advantages. First, low-power CW laser diodes and entangled photon source design lead to straightforward on-chip integration for a direct path to distributable fluorescence lifetime measurements. Second, the entangled pair's wavelength is easily tuned by adjusting the temperature or electric field, allowing a single source to cover octave bandwidths. Third, femtosecond temporal resolutions can be reached without requiring major advances in source technology or external phase modulation. Entangled photons could therefore provide increased accessibility to time-resolved fluorescence while also opening new scientific avenues in photosensitive and inherently quantum systems.

arXiv:2305.07108•The Journal of Physical Chemistry Letters•Jun 20, 2023•21 citations

Fluorescence lifetime measurements using photon pair correlations generated via spontaneous parametric down conversion (SPDC)

Audrey V. Eshun, Xiyu Yi, Ashleigh K. Wilson +6 more

We have used photon pair correlations generated via spontaneous parametric downconversion (SPDC) to measure the fluorescence lifetime of the organic dye rhodamine 6 G, demonstrating that fluorescence lifetime measurements can be achieved using a continuous wave (CW) laser, without pulsed or modulated lasers. Our entangled photon method, quantum fluorescence lifetime (Q-FL) measurements, uses one photon to excite fluorescence and the resulting fluorescence photon is timed and referenced to the arrival time of the other entangled photon. Thus, we can exploit the short timescale of photon pair correlations to conduct experiments that are typically carried out with pulsed lasers and we show that the inherent timing of the photons is fast enough to resolve the nanosecond scale fluorescence lifetime of the sample. This measurement paves the way towards using the time correlations of entangled photons for fluorescence imaging; capitalizing on the presence of fast, sub-100 ps correlations that have not been demonstrated classically.

Optics Express•Jul 14, 2023•16 citations

Correlated-photon time- and frequency-resolved optical spectroscopy

Raúl Álvarez-Mendoza, Lorenzo Uboldi, Ashley Lyons +3 more

Classical time-resolved optical spectroscopy experiments are performed using sequences of ultrashort light pulses, with photon fluxes incident on the sample which are many orders of magnitude higher than real-world conditions corresponding to sunlight illumination. Spectroscopy and microscopy schemes that use quantum states of light have been widely described theoretically with fewer experimental demonstrations that typically require very long measurements that can extend for hours or more. Here, we show that time-resolved spectroscopy with quantum light can be performed without compromising measurement time or wavelength tunability, recording a fluorescence lifetime trace in biological samples in less than a second with acceptable signal-to-noise ratio. Starting from spontaneous parametric down-conversion driven by a continuous-wave laser, we exploit the temporal correlation between randomly generated signal/idler pairs to obtain temporal resolution, and their spectral correlation to select the excitation frequency. We also add spectral resolution in detection, using a 'photon-efficient' Fourier transform approach which employs a common-path interferometer. We demonstrate the potential of this approach by resolving, at the single-photon level, excitation energy transfer cascades from LH2 to LH1 in the photosynthetic membrane and disentangling the lifetimes of two dyes in a mixture. Our results provide a new approach to ultrafast optical spectroscopy, where experiments are performed under illumination intensity conditions comparable to real-world sunlight illumination.

arXiv:2505.02940•Nature Communications•Sep 30, 2025•11 citations

Fluorescence lifetime measurement based on quantum sensing

Giuseppe Di Blasio, Federico Simoni, Lorenzo Uboldi +5 more

Quantum light sources, such as entangled photons, offers unique advantages for bio-sensing of light sensitive samples, providing background free and high SNR measurements at ultra-low photon flux. We built a modular set-up based on SPDC entangled photon pairs generation by using a pulsed laser and several single-photon detectors with different time resolution and quantum efficiency to investigate fluorescent complexes. This toolkit paves the way for minimally invasive fluorescence lifetime sensing towards next generation in vivo studies.

Quantum Effects and Measurement Techniques in Biology and Biophotonics•Mar 4, 2026•0 citations

Development of time-resolved fluorescence spectroscopy using heralded emission spectroscopy for organic light-emitting materials

Nicola J. Fairbairn, Koya Onoda, Ozora Iso +7 more

Organic light-emitting materials are widely used in optoelectronics and bioimaging, but sometimes conventional fluorescence spectroscopy techniques can be limited by scattering, background fluorescence, photon pile-up and photobleaching. We report a quantum-spectroscopic approach using frequency-entangled, nondegenerate photon pairs generated via spontaneous parametric down-conversion with heralded detection, to perform photoluminescence lifetime measurements at low excitation intensities. We demonstrate this approach across three organic light-emitting material classes: the fluorescent dye Rhodamine 6G, an organic semiconducting conjugated polymer poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV), and a fluorescent protein mOrange. The intrinsic timing correlation between signal and idler photons enables coincidence gating that suppresses uncorrelated background counts. Across all materials and integration times of 500, 1000 and 3600 seconds, heralded detection yields signal-to-noise ratios 1.6-3.0 times higher than classical pulsed-laser excitation attenuated to match heralded photon counts in the fitting range. For MEH-PPV, this roughly halves the noise amplitude. Our measured lifetimes closely match long-integration classical pulsed-laser reference values.

arXiv:2611.07770•Nov 5, 2026•0 citations

Experimental test of the entanglement enhancement in two-photon fluorescence

Gewei Qian, Xiao Liu, Chenran Xu +2 more

Abstract Entangled photons with time-energy correlations are predicted to have improved sensitivity compared with classical light in two-photon fluorescence, which is promising for lowering the phototoxicity in biomedical imaging. While the mechanism has been demonstrated in atoms and crystals, the effectiveness in biological molecules has been under debate. Here we report the experimental results, including both positive and negative ones, in various samples. While entanglement induced enhancement in the sum frequency generation of a nonlinear crystal was confirmed, we observe no such enhancement in the two-photon nonlinear process of various molecules. However, we observed classical two-photon fluorescence excited by nW light in rare earth element doped core-shell structure nano-crystals, which can also be used in sensitive biomedical imaging. Our results provide guidance in characterizing the effect of entanglement in two-photon processes.

Quantum Frontiers•Feb 28, 2024•5 citations
Abstract The investigation of fluorescence lifetime became an important tool in biology and medical science. So far, established methods of fluorescence lifetime measurements require the illumination of the investigated probes with pulsed or amplitude-modulated light. In this paper, we examine the limitations of an innovative method of fluorescence lifetime using the strong time-frequency correlation of entangled photons generated by a continuous-wave source. For this purpose, we investigate the lifetime of IR-140 to demonstrate the functional principle and its dependencies on different experimental parameters. We also compare this technique with state-of-the-art FLIM and observed an improved figure-of-merit. Finally, we discuss the potential of a quantum advantage.
Fluorescence lifetime experiments are a standard approach for measuring excited-state dynamics and local environmental effects. Here, we show that entangled photon pairs produced from a continuous-wave (CW) laser diode can replicate pulsed laser experiments without phase modulation. As a proof of principle, picosecond fluorescence lifetimes of indocyanine green are measured in multiple environments. The use of entangled photons has three unique advantages. First, low-power CW laser diodes and entangled photon source design lead to straightforward on-chip integration for a direct path to distributable fluorescence lifetime measurements. Second, the entangled pair's wavelength is easily tuned by adjusting the temperature or electric field, allowing a single source to cover octave bandwidths. Third, femtosecond temporal resolutions can be reached without requiring major advances in source technology or external phase modulation. Entangled photons could therefore provide increased accessibility to time-resolved fluorescence while also opening new scientific avenues in photosensitive and inherently quantum systems.
We have used photon pair correlations generated via spontaneous parametric downconversion (SPDC) to measure the fluorescence lifetime of the organic dye rhodamine 6 G, demonstrating that fluorescence lifetime measurements can be achieved using a continuous wave (CW) laser, without pulsed or modulated lasers. Our entangled photon method, quantum fluorescence lifetime (Q-FL) measurements, uses one photon to excite fluorescence and the resulting fluorescence photon is timed and referenced to the arrival time of the other entangled photon. Thus, we can exploit the short timescale of photon pair correlations to conduct experiments that are typically carried out with pulsed lasers and we show that the inherent timing of the photons is fast enough to resolve the nanosecond scale fluorescence lifetime of the sample. This measurement paves the way towards using the time correlations of entangled photons for fluorescence imaging; capitalizing on the presence of fast, sub-100 ps correlations that have not been demonstrated classically.
Classical time-resolved optical spectroscopy experiments are performed using sequences of ultrashort light pulses, with photon fluxes incident on the sample which are many orders of magnitude higher than real-world conditions corresponding to sunlight illumination. Spectroscopy and microscopy schemes that use quantum states of light have been widely described theoretically with fewer experimental demonstrations that typically require very long measurements that can extend for hours or more. Here, we show that time-resolved spectroscopy with quantum light can be performed without compromising measurement time or wavelength tunability, recording a fluorescence lifetime trace in biological samples in less than a second with acceptable signal-to-noise ratio. Starting from spontaneous parametric down-conversion driven by a continuous-wave laser, we exploit the temporal correlation between randomly generated signal/idler pairs to obtain temporal resolution, and their spectral correlation to select the excitation frequency. We also add spectral resolution in detection, using a 'photon-efficient' Fourier transform approach which employs a common-path interferometer. We demonstrate the potential of this approach by resolving, at the single-photon level, excitation energy transfer cascades from LH2 to LH1 in the photosynthetic membrane and disentangling the lifetimes of two dyes in a mixture. Our results provide a new approach to ultrafast optical spectroscopy, where experiments are performed under illumination intensity conditions comparable to real-world sunlight illumination.
Quantum light sources, such as entangled photons, offers unique advantages for bio-sensing of light sensitive samples, providing background free and high SNR measurements at ultra-low photon flux. We built a modular set-up based on SPDC entangled photon pairs generation by using a pulsed laser and several single-photon detectors with different time resolution and quantum efficiency to investigate fluorescent complexes. This toolkit paves the way for minimally invasive fluorescence lifetime sensing towards next generation in vivo studies.
Organic light-emitting materials are widely used in optoelectronics and bioimaging, but sometimes conventional fluorescence spectroscopy techniques can be limited by scattering, background fluorescence, photon pile-up and photobleaching. We report a quantum-spectroscopic approach using frequency-entangled, nondegenerate photon pairs generated via spontaneous parametric down-conversion with heralded detection, to perform photoluminescence lifetime measurements at low excitation intensities. We demonstrate this approach across three organic light-emitting material classes: the fluorescent dye Rhodamine 6G, an organic semiconducting conjugated polymer poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV), and a fluorescent protein mOrange. The intrinsic timing correlation between signal and idler photons enables coincidence gating that suppresses uncorrelated background counts. Across all materials and integration times of 500, 1000 and 3600 seconds, heralded detection yields signal-to-noise ratios 1.6-3.0 times higher than classical pulsed-laser excitation attenuated to match heralded photon counts in the fitting range. For MEH-PPV, this roughly halves the noise amplitude. Our measured lifetimes closely match long-integration classical pulsed-laser reference values.
Abstract Entangled photons with time-energy correlations are predicted to have improved sensitivity compared with classical light in two-photon fluorescence, which is promising for lowering the phototoxicity in biomedical imaging. While the mechanism has been demonstrated in atoms and crystals, the effectiveness in biological molecules has been under debate. Here we report the experimental results, including both positive and negative ones, in various samples. While entanglement induced enhancement in the sum frequency generation of a nonlinear crystal was confirmed, we observe no such enhancement in the two-photon nonlinear process of various molecules. However, we observed classical two-photon fluorescence excited by nW light in rare earth element doped core-shell structure nano-crystals, which can also be used in sensitive biomedical imaging. Our results provide guidance in characterizing the effect of entanglement in two-photon processes.