We report our investigations on the dependence of magnetic resonance spectrum on the light ellipticity and the polarization angle. A rubidium vapor cell with octade-cyltrichlorosilane (OTS) antirelaxation coating has been used in our experiment to produce narrow linewidth magnetic resonances. We show that excitation using elliptically polarized light can simultaneously produce the alignment and orientation resonances in a Bell-Bloom interaction geometry. We have developed a theoretical model to calculate the resonance spectrum using light with a varying degree of ellipticity. Amplitudes of the alignment and orientation resonances show a strong dependence on the light ellipticity. Our study shows that the duty cycle of light modulation can effectively control the amplitude variations of the alignment and orientation resonances with light ellipticity. We propose that the difference between the alignment and orientation resonance amplitudes can be used for in situ measurement of the light
We investigate an all-optical scheme for high-sensitivity measurements of the Earth's scale magnetic field (
B). The scheme is based on the Bell-Bloom technique with frequency-modulated light. A single elliptically polarized light beam is used both for pumping the alkali-metal atoms and probing Larmor precession of their spins under the external magnetic field. In contrast to many other high-sensitivity magnetometry schemes based on nonlinear polarization rotation of the light, the proposed approach enables the observation of magnetic resonance via changes in the light-beam ellipticity parameter. The approach has been validated in experiments with a vertical-cavity surface-emitting laser, irradiating a
0.125 cm
3 cesium vapor cell filled with a buffer gas. In the current experimental conditions, the achieved sensitivity is estimated at
220 fT/
√Hz under
B≈50 μT, while the shot-noise floor corresponds to
≈20 fT/
√Hz. The bandwidth is estimated at
≈1 kHz. The proposed simple and robust single-beam scheme is well suited for miniaturization and is therefore particularly promising for the development of compact, highly sensitive, low-power-consumption atomic magnetometers for a wide range of applications in the geomagnetic field.
The detection dead zones and heading errors induced by light shifts are two important problems in optically pumped scalar magnetometry. We introduce an atomic-orientation-based single-beam magnetometry scheme to simultaneously solve these problems, using a polarization-reversing and path-bending Herriott cavity. Here, a reflection mirror is inserted into the cavity to bend the optical paths in the middle and divide them into two separated orthogonal regions to avoid the detection dead zone. Moreover, half-wave plates are added in the center of each optical region, so that the light polarization is flipped each time it passes the wave plates and the light-shift effects are spatially averaged out. This operation is demonstrated to eliminate the unnoticed heading errors induced by ac light shifts. The methods developed in this paper are robust to use and easy to apply other atomic devices.