Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2407.13723 · Physics of Fluids

Superresolving optical ruler based on spatial mode demultiplexing for systems evolving under Brownian motion

Konrad Schlichtholz

Published Feb 1, 2025• 1 citation
arXivHTMLPDF

Abstract

The development of super-resolution techniques, i.e., allowing for efficient resolution below the Rayleigh limit, became one of the important branches in contemporary optics and metrology. Recent findings show that perfect spatial mode demultiplexing (SPADE) into Hermite-Gauss modes followed by photon counting enables one to reach the quantum limit of precision in the task of estimation of separation between two weak stationary sources in the sub-Rayleigh regime. In order to check the limitations of the method, various imperfections such as misalignment or crosstalk between the modes were considered. Possible applications of the method in microscopy call for the adaptive measurement scheme, as the position of the measured system can evolve in time, causing non-negligible misalignment. In this paper, we examine the impact of Brownian motion of the center of the system of two weak incoherent sources on adaptive SPADE measurement precision limits. The analysis is carried out using Fisher information, from which the limit of precision can be obtained by Cramér-Rao bound. As a result, we find that Rayleigh's curse is present in such a scenario; however, SPADE measurement can outperform perfect direct imaging. What is more, a suitable adjustment of the measurement time between alignments allows measurement with near-optimal precision.

DOI
10.1063/5.0252056

Related papers

Superresolution in separation estimation between two dynamic incoherent sources using spatial demultiplexing

Konrad Schlichtholz, Łukasz Rudnicki

Abstract Achieving resolution in the sub-Rayleigh regime (superresolution) is one of the rapidly developing topics in quantum optics and metrology. Recently, it was shown that perfect measurement based on spatial mode demultiplexing (SPADE) in Hermite–Gauss modes allows one to reach the quantum limit of precision for estimation of separation between two weak incoherent stationary sources. Since then, different imperfections such as misalignment or crosstalk between modes have been studied to check how this result translates into more realistic experimental setups. In this paper, we consider another deviation from the perfect setup by discarding the assumption about the stationarity of the sources. This is relevant for example for astrophysical applications where planets necessarily orbit around the star. We analyze two examples of dynamics: rotations and oscillations, showing the robustness of the SPADE-based measurement against them. The analysis is based on Fisher information, which allows one to obtain the precision limit through Cramér–Rao bound. Furthermore, we formulate a measurement algorithm that allows for the reduction of one parameter for estimation (system orientation angle) in the stationary sources scenario, maintaining the measurement precision despite the lack of knowledge about this parameter.

arXiv:2407.10507•New Journal of Physics•Nov 14, 2024•4 citations

Superresolution Enhancement in Biphoton Spatial-Mode Demultiplexing

Florence Grenapin, Dilip Paneru, Alessio D’Errico +3 more

Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and, thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wave function. Here, we consider the case in which the light field originates from a biphoton source, i.e., spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be superresolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably, the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by $\sqrt{K}$, where $K$ is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.

Physical Review Applied•Aug 31, 2023•11 citations

Parameter estimation approach to super resolution

Alexander Boeschoten, Antonin Grateau, Clémentine Rouvière +7 more

The resolution of optical systems, formulated as the smallest possible distance between two point sources for which they still can be dissolved, was for a long time believed to be limited by diffraction, formulated by the Rayleigh criterion. Recent advancements in quantum metrology have shown, by evaluation of the Quantum Cramér Rao bound (QCRB), that the Rayleigh criterion is not a fundamental limit. In our experiment, spatial mode demultiplexing (SPADE) is used to estimate the separation of the sources orders of magnitude below the Rayleigh limit. The experiment is extended to incorporate the measurement of additional parameters, such as power imbalance and centroid position of the two sources, bringing it closer to real-world applicability.

SPIE Quantum Technologies for Defence and Security•Nov 15, 2024•0 citations

Super-resolution enhancement in bi-photon spatial mode demultiplexin

Florence Grenapin, Dilip Paneru, Alessio D’Errico +3 more

Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wavefunction. Here, we consider the case in which the light field originates from a bi-photon source, i.e. spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be super-resolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by $\sqrt{K}$, where $K$ is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.

arXiv:2212.10468•Dec 20, 2022•3 citations

Multiparameter estimation for the superresolution of two incoherent sources

Antonin Grateau, Alexander Boeschoten, Tanguy Favin-Lévêque +2 more

We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.

quant-pharXiv:2601.14876•Physical Review Letters•Jan 22, 2026•0 citations

Application range of crosstalk-affected spatial demultiplexing for resolving separations between unbalanced sources

Tomasz Linowski, Konrad Schlichtholz, Giacomo Sorelli +4 more

Abstract Super resolution is one of the key issues at the crossroads of contemporary quantum optics and metrology. Recently, it was shown that for an idealized case of two balanced sources, spatial mode demultiplexing (SPADE) achieves resolution better than direct imaging even in the presence of measurement crosstalk (Gessner et al 2020 Phys. Rev. Lett. 125 100501). In this work, we consider arbitrarily unbalanced sources and provide a systematic analysis of the impact of crosstalk on the resolution obtained from SPADE. As we dissect, in this generalized scenario, SPADE’s effectiveness depends non-trivially on the strength of crosstalk, relative brightness and the separation between the sources. In particular, for any source imbalance, SPADE performs worse than ideal direct imaging in the asymptotic limit of vanishing source separations. Nonetheless, for realistic values of crosstalk strength, SPADE is still the superior method for several orders of magnitude of source separations.

New Journal of Physics•Oct 1, 2023•12 citations
The development of super-resolution techniques, i.e., allowing for efficient resolution below the Rayleigh limit, became one of the important branches in contemporary optics and metrology. Recent findings show that perfect spatial mode demultiplexing (SPADE) into Hermite-Gauss modes followed by photon counting enables one to reach the quantum limit of precision in the task of estimation of separation between two weak stationary sources in the sub-Rayleigh regime. In order to check the limitations of the method, various imperfections such as misalignment or crosstalk between the modes were considered. Possible applications of the method in microscopy call for the adaptive measurement scheme, as the position of the measured system can evolve in time, causing non-negligible misalignment. In this paper, we examine the impact of Brownian motion of the center of the system of two weak incoherent sources on adaptive SPADE measurement precision limits. The analysis is carried out using Fisher information, from which the limit of precision can be obtained by Cramér-Rao bound. As a result, we find that Rayleigh's curse is present in such a scenario; however, SPADE measurement can outperform perfect direct imaging. What is more, a suitable adjustment of the measurement time between alignments allows measurement with near-optimal precision.
Abstract Achieving resolution in the sub-Rayleigh regime (superresolution) is one of the rapidly developing topics in quantum optics and metrology. Recently, it was shown that perfect measurement based on spatial mode demultiplexing (SPADE) in Hermite–Gauss modes allows one to reach the quantum limit of precision for estimation of separation between two weak incoherent stationary sources. Since then, different imperfections such as misalignment or crosstalk between modes have been studied to check how this result translates into more realistic experimental setups. In this paper, we consider another deviation from the perfect setup by discarding the assumption about the stationarity of the sources. This is relevant for example for astrophysical applications where planets necessarily orbit around the star. We analyze two examples of dynamics: rotations and oscillations, showing the robustness of the SPADE-based measurement against them. The analysis is based on Fisher information, which allows one to obtain the precision limit through Cramér–Rao bound. Furthermore, we formulate a measurement algorithm that allows for the reduction of one parameter for estimation (system orientation angle) in the stationary sources scenario, maintaining the measurement precision despite the lack of knowledge about this parameter.
Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and, thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wave function. Here, we consider the case in which the light field originates from a biphoton source, i.e., spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be superresolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably, the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by K\sqrt{K}K​, where KKK is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.
The resolution of optical systems, formulated as the smallest possible distance between two point sources for which they still can be dissolved, was for a long time believed to be limited by diffraction, formulated by the Rayleigh criterion. Recent advancements in quantum metrology have shown, by evaluation of the Quantum Cramér Rao bound (QCRB), that the Rayleigh criterion is not a fundamental limit. In our experiment, spatial mode demultiplexing (SPADE) is used to estimate the separation of the sources orders of magnitude below the Rayleigh limit. The experiment is extended to incorporate the measurement of additional parameters, such as power imbalance and centroid position of the two sources, bringing it closer to real-world applicability.
Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wavefunction. Here, we consider the case in which the light field originates from a bi-photon source, i.e. spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be super-resolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by K\sqrt{K}K​, where KKK is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.
We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.
Abstract Super resolution is one of the key issues at the crossroads of contemporary quantum optics and metrology. Recently, it was shown that for an idealized case of two balanced sources, spatial mode demultiplexing (SPADE) achieves resolution better than direct imaging even in the presence of measurement crosstalk (Gessner et al 2020 Phys. Rev. Lett. 125 100501). In this work, we consider arbitrarily unbalanced sources and provide a systematic analysis of the impact of crosstalk on the resolution obtained from SPADE. As we dissect, in this generalized scenario, SPADE’s effectiveness depends non-trivially on the strength of crosstalk, relative brightness and the separation between the sources. In particular, for any source imbalance, SPADE performs worse than ideal direct imaging in the asymptotic limit of vanishing source separations. Nonetheless, for realistic values of crosstalk strength, SPADE is still the superior method for several orders of magnitude of source separations.