Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Superresolution Enhancement in Biphoton Spatial-Mode Demultiplexing

Florence Grenapin, Dilip Paneru, Alessio D’Errico, Vincenzo Grillo, Gerd Leuchs, Ebrahim Karimi

Published Aug 31, 2023• 11 citations
Publisher

Abstract

Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and, thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wave function. Here, we consider the case in which the light field originates from a biphoton source, i.e., spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be superresolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably, the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by $\sqrt{K}$, where $K$ is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.

DOI
10.1103/physrevapplied.20.024077

Related papers

Super-resolution enhancement in bi-photon spatial mode demultiplexin

Florence Grenapin, Dilip Paneru, Alessio D’Errico +3 more

Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wavefunction. Here, we consider the case in which the light field originates from a bi-photon source, i.e. spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be super-resolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by $\sqrt{K}$, where $K$ is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.

arXiv:2212.10468•Dec 20, 2022•3 citations

Superresolving optical ruler based on spatial mode demultiplexing for systems evolving under Brownian motion

Konrad Schlichtholz

The development of super-resolution techniques, i.e., allowing for efficient resolution below the Rayleigh limit, became one of the important branches in contemporary optics and metrology. Recent findings show that perfect spatial mode demultiplexing (SPADE) into Hermite-Gauss modes followed by photon counting enables one to reach the quantum limit of precision in the task of estimation of separation between two weak stationary sources in the sub-Rayleigh regime. In order to check the limitations of the method, various imperfections such as misalignment or crosstalk between the modes were considered. Possible applications of the method in microscopy call for the adaptive measurement scheme, as the position of the measured system can evolve in time, causing non-negligible misalignment. In this paper, we examine the impact of Brownian motion of the center of the system of two weak incoherent sources on adaptive SPADE measurement precision limits. The analysis is carried out using Fisher information, from which the limit of precision can be obtained by Cramér-Rao bound. As a result, we find that Rayleigh's curse is present in such a scenario; however, SPADE measurement can outperform perfect direct imaging. What is more, a suitable adjustment of the measurement time between alignments allows measurement with near-optimal precision.

arXiv:2407.13723•Physics of Fluids•Feb 1, 2025•1 citation

Resolution limits of spatial mode demultiplexing with noisy detection

Yink Loong Len, Chandan Datta, Michal P. Parniak +1 more

We consider the problem of estimating the spatial separation between two mutually incoherent point light sources using the super-resolution imaging technique based on spatial mode demultiplexing (SPADE) with noisy detectors. We show that in the presence of noise, the resolution of the measurement is limited by the signal-to-noise ratio (SNR) and the minimum resolvable spatial separation has a characteristic dependence of [Formula: see text]. Several detection techniques, including direct photon counting, as well as homodyne and heterodyne detection are considered.

arXiv:1911.04744•International Journal of Quantum Information•Jan 31, 2020•51 citations

Superresolution in separation estimation between two dynamic incoherent sources using spatial demultiplexing

Konrad Schlichtholz, Łukasz Rudnicki

Abstract Achieving resolution in the sub-Rayleigh regime (superresolution) is one of the rapidly developing topics in quantum optics and metrology. Recently, it was shown that perfect measurement based on spatial mode demultiplexing (SPADE) in Hermite–Gauss modes allows one to reach the quantum limit of precision for estimation of separation between two weak incoherent stationary sources. Since then, different imperfections such as misalignment or crosstalk between modes have been studied to check how this result translates into more realistic experimental setups. In this paper, we consider another deviation from the perfect setup by discarding the assumption about the stationarity of the sources. This is relevant for example for astrophysical applications where planets necessarily orbit around the star. We analyze two examples of dynamics: rotations and oscillations, showing the robustness of the SPADE-based measurement against them. The analysis is based on Fisher information, which allows one to obtain the precision limit through Cramér–Rao bound. Furthermore, we formulate a measurement algorithm that allows for the reduction of one parameter for estimation (system orientation angle) in the stationary sources scenario, maintaining the measurement precision despite the lack of knowledge about this parameter.

arXiv:2407.10507•New Journal of Physics•Nov 14, 2024•4 citations

Application range of crosstalk-affected spatial demultiplexing for resolving separations between unbalanced sources

Tomasz Linowski, Konrad Schlichtholz, Giacomo Sorelli +4 more

Superresolution is one of the key issues at the crossroads of contemporary quantum optics and metrology. Recently, it was shown that for an idealized case of two balanced sources, spatial mode demultiplexing (SPADE) achieves resolution better than direct imaging even in the presence of measurement crosstalk [Phys. Rev. Lett. 125, 100501 (2020)]. In this work, we consider arbitrarily unbalanced sources and provide a systematic analysis of the impact of crosstalk on the resolution obtained from SPADE. As we dissect, in this generalized scenario, SPADE's effectiveness depends non-trivially on the strength of crosstalk, relative brightness and the separation between the sources. In particular, for any source imbalance, SPADE performs worse than ideal direct imaging in the asymptotic limit of vanishing source separations. Nonetheless, for realistic values of crosstalk strength, SPADE is still the superior method for several orders of magnitude of source separations.

arXiv:2211.09157•Nov 16, 2022•3 citations

Ultra-sensitive separation estimation of optical sources

Clémentine Rouvière, David Barral, Antonin Grateau +4 more

Historically, the resolution of optical imaging systems was dictated by diffraction, and the Rayleigh criterion was long considered an unsurpassable limit. In superresolution microscopy, this limit is overcome by manipulating the emission properties of the object. However, in passive imaging, when sources are uncontrolled, reaching sub-Rayleigh resolution remains a challenge. Here, we implement a quantum-metrolgy-inspired approach for estimating the separation between two incoherent sources, achieving a sensitivity five orders of magnitude beyond the Rayleigh limit. Using a spatial mode demultiplexer, we examine scenes with bright and faint sources, through intensity measurements in the Hermite-Gauss basis. Analysing sensitivity and accuracy over an extensive range of separations, we demonstrate the remarkable effectiveness of demultiplexing for sub-Rayleigh separation estimation. These results effectively render the Rayleigh limit obsolete for passive imaging.

arXiv:2306.11916•Jun 20, 2023•2 citations
Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and, thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wave function. Here, we consider the case in which the light field originates from a biphoton source, i.e., spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be superresolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably, the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by K\sqrt{K}K​, where KKK is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.
Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wavefunction. Here, we consider the case in which the light field originates from a bi-photon source, i.e. spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be super-resolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by K\sqrt{K}K​, where KKK is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.
The development of super-resolution techniques, i.e., allowing for efficient resolution below the Rayleigh limit, became one of the important branches in contemporary optics and metrology. Recent findings show that perfect spatial mode demultiplexing (SPADE) into Hermite-Gauss modes followed by photon counting enables one to reach the quantum limit of precision in the task of estimation of separation between two weak stationary sources in the sub-Rayleigh regime. In order to check the limitations of the method, various imperfections such as misalignment or crosstalk between the modes were considered. Possible applications of the method in microscopy call for the adaptive measurement scheme, as the position of the measured system can evolve in time, causing non-negligible misalignment. In this paper, we examine the impact of Brownian motion of the center of the system of two weak incoherent sources on adaptive SPADE measurement precision limits. The analysis is carried out using Fisher information, from which the limit of precision can be obtained by Cramér-Rao bound. As a result, we find that Rayleigh's curse is present in such a scenario; however, SPADE measurement can outperform perfect direct imaging. What is more, a suitable adjustment of the measurement time between alignments allows measurement with near-optimal precision.
We consider the problem of estimating the spatial separation between two mutually incoherent point light sources using the super-resolution imaging technique based on spatial mode demultiplexing (SPADE) with noisy detectors. We show that in the presence of noise, the resolution of the measurement is limited by the signal-to-noise ratio (SNR) and the minimum resolvable spatial separation has a characteristic dependence of [Formula: see text]. Several detection techniques, including direct photon counting, as well as homodyne and heterodyne detection are considered.
Abstract Achieving resolution in the sub-Rayleigh regime (superresolution) is one of the rapidly developing topics in quantum optics and metrology. Recently, it was shown that perfect measurement based on spatial mode demultiplexing (SPADE) in Hermite–Gauss modes allows one to reach the quantum limit of precision for estimation of separation between two weak incoherent stationary sources. Since then, different imperfections such as misalignment or crosstalk between modes have been studied to check how this result translates into more realistic experimental setups. In this paper, we consider another deviation from the perfect setup by discarding the assumption about the stationarity of the sources. This is relevant for example for astrophysical applications where planets necessarily orbit around the star. We analyze two examples of dynamics: rotations and oscillations, showing the robustness of the SPADE-based measurement against them. The analysis is based on Fisher information, which allows one to obtain the precision limit through Cramér–Rao bound. Furthermore, we formulate a measurement algorithm that allows for the reduction of one parameter for estimation (system orientation angle) in the stationary sources scenario, maintaining the measurement precision despite the lack of knowledge about this parameter.
Superresolution is one of the key issues at the crossroads of contemporary quantum optics and metrology. Recently, it was shown that for an idealized case of two balanced sources, spatial mode demultiplexing (SPADE) achieves resolution better than direct imaging even in the presence of measurement crosstalk [Phys. Rev. Lett. 125, 100501 (2020)]. In this work, we consider arbitrarily unbalanced sources and provide a systematic analysis of the impact of crosstalk on the resolution obtained from SPADE. As we dissect, in this generalized scenario, SPADE's effectiveness depends non-trivially on the strength of crosstalk, relative brightness and the separation between the sources. In particular, for any source imbalance, SPADE performs worse than ideal direct imaging in the asymptotic limit of vanishing source separations. Nonetheless, for realistic values of crosstalk strength, SPADE is still the superior method for several orders of magnitude of source separations.
Historically, the resolution of optical imaging systems was dictated by diffraction, and the Rayleigh criterion was long considered an unsurpassable limit. In superresolution microscopy, this limit is overcome by manipulating the emission properties of the object. However, in passive imaging, when sources are uncontrolled, reaching sub-Rayleigh resolution remains a challenge. Here, we implement a quantum-metrolgy-inspired approach for estimating the separation between two incoherent sources, achieving a sensitivity five orders of magnitude beyond the Rayleigh limit. Using a spatial mode demultiplexer, we examine scenes with bright and faint sources, through intensity measurements in the Hermite-Gauss basis. Analysing sensitivity and accuracy over an extensive range of separations, we demonstrate the remarkable effectiveness of demultiplexing for sub-Rayleigh separation estimation. These results effectively render the Rayleigh limit obsolete for passive imaging.