Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2405.15017 · Communications Engineering

Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout

Paul Szypryt, D. A. Bennett, I. M. Fogarty Florang, Joseph W. Fowler, Andrea Giachero, Ruslan Hummatov, Adriana E. Lita, John A. B. Mates, Sae Woo Nam, G. C. O’Neil, Daniel S. Swetz, Joel N. Ullom, Michael R. Vissers, Jordan Wheeler, Jiansong Gao

Published Nov 6, 2024• 17 citations
arXivHTMLPDF

Abstract

Abstract Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of $$1.4\,{{{\rm{pA}}}}/\sqrt{{{{\rm{Hz}}}}}$$ 1.4 pA / Hz , considerably below the detector noise at frequencies of interest, and an energy resolution of (0.137 ± 0.001) eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.

DOI
10.1038/s44172-024-00308-y

Related papers

Superconducting Nonlinear Kinetic Inductance Devices

Kher, Aditya Shreyas

We describe a novel class of devices based on the nonlinearity of the kinetic inductance of a superconducting thin film. By placing a current-dependent inductance in a microwave resonator, small currents can be measured through their effect on the resonator’s frequency. By using a high-resistivity material for the film and nanowires as kinetic inductors, we can achieve a large coefficient of nonlinearity to improve device sensitivity. We demonstrate a current sensitivity of 8 pA/√Hz, making this device useful for transition-edge sensor (TES) readout and other cutting-edge applications. An advantage of these devices is their natural ability to be multiplexed in the frequency domain, enabling large detector arrays for TES-based instruments. A traveling-wave version of the device, consisting of a thin-film microwave transmission line, is also sensitive to small currents as they change the phase length of the line due to their effect on its inductance. We demonstrate a current sensitivity of 5 pA/√Hz for this version of the device, making it also suitable for TES readout as well as other current-detection applications. It has the advantage of multi-gigahertz bandwidth and greater dynamic range, offering a different approach to the resonator version of the device. Finally, we also demonstrate a transmission-line resonator version of the device that combines some of the advantages of the nanowire resonator and the traveling-wave device. This version of the device has high dynamic range but can also be easily multiplexed in the frequency domain. A lumped-element resonator similar to the first device can be placed in a loop configuration to make it sensitive to magnetic fields. We demonstrate an example of such a device whose sensitivity could ultimately reach levels similar to those of state-of-the-art DC SQUIDs, making it potentially useful for many magnetometry applications given its ease of multiplexing. Finally, a similar microwave resonator is shown to exhibit parametric gain of up to 29 dB in the presence of a strong pump tone. The noise performance of this parametric amplifier approaches the quantum limit, making it useful for applications in quantum information and metrology.

•Feb 10, 2017•17 citations

Compact microwave kinetic inductance nanowire galvanometer for cryogenic detectors at 4.2 K

S Doerner, Artem A. Kuzmin, K Graf +3 more

We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range for large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4 nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art current readout approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured can directly be injected without having the need of an impedance matching circuit, reducing the system complexity. With the proof-of-concept device we measured a current noise floor δI min of 10 pA/Hz 1/2 at 10 kHz. Furthermore, we demonstrate the ability of our sensor to amplify a pulsed response of a superconducting nanowire single-photon detector using a GHz-range carrier for effective frequency-division multiplexing.

Journal of Physics Communications•Jan 25, 2018•8 citations

Compact microwave kinetic inductance nanowire galvanometer for cryogenic detectors at 4.2 K

Doerner, S., Artem A. Kuzmin, Graf, K. +3 more

We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range of large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4-nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured can directly be injected without having the need of an impedance matching circuit, reducing the system complexity. With the proof-of-concept device we measured a current noise floor δImin of 10 pA/Hz1/2 at 10 kHz. Furthermore, we demonstrate the ability of our sensor to amplify a pulsed response of a superconducting nanowire single-photon detector using a GHz-range carrier for effective frequency-division multiplexing.

arXiv:1709.02640•Sep 8, 2017•0 citations

Prospects of Kinetic Inductance Current Sensors for Multiplexed Microcalorimeter Readout

G. C. O’Neil, S. R. Bandler, I. M. Fogarty Florang +9 more

Superconducting microcalorimeter arrays with hundreds to thousands of pixels are enabling new measurements and capabilities in exotic atom spectroscopy, x-ray astronomy, nuclear materials analysis, and many other fields. We consider the prospects of multiplexing microcalorimeters with the kinetic inductance current sensor (KICS), an alternative to the superconducting quantum interference device (SQUID) historically used to read out cryogenic microcalorimeters. We show that the amplifier limited noise of the KICS is determined by its dynamic range, which is a free design parameter and tuneable with a DC current bias. We predict that KICS can meet the requirements to read out prototype metallic magnetic calorimeter (MMC) pixels designed for the Lynx x-ray satellite mission concept with the use of low-latency tone tracking. We propose a KICS design that has both high coupling efficiency and high isolation between the RF and DC components of the circuit. We argue that the KICS provides engineering trade-offs that are better suited to the readout of microcalorimeters when compared to the analogous microwave SQUID multiplexer.

IEEE Transactions on Applied Superconductivity•Mar 13, 2026•0 citations

Design and performance of hafnium optical and near-IR kinetic inductance detectors

Nicholas Zobrist, Grégoire Coiffard, Bruce Bumble +9 more

We report on the design and performance of microwave kinetic inductance detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 μΩ cm with RRR=1.6. Resonators on the device displayed internal quality factors of around 200 000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process, which resulted in pixels with decay times of about 40 μs and resolving powers of ∼9 at 800 nm.

arXiv:1911.06434•Applied Physics Letters•Nov 18, 2019•28 citations

Frequency Division Multiplexers for TES Readout Based on Microwave Resonators

Satoshi Kohjiro, Fuminori Hirayama, Daiji Fukuda +3 more

Dissipationless microwave radio frequency superconducting interference device (RF-SQUID) multiplexers are attractive for readouts of large format arrays of transition edge sensors (TES). This multiplexer has the potential for readout bandwidth of several GHz and power consumption of ≈0.1 pW per pixel, which are ≈103 and ≈10-4 times as large as those of DC-SQUID-based conventional multiplexers. To evaluate their readout performance for TES photon counters ranging from near infrared to gamma ray, white noise of this multiplexer was experimentally studied at 4 K. The reason for this was, firstly, to avoid the low-frequency fluctuation obvious at around 0.1 K but trivial for the energy resolution of photon counters, and secondly for a feasibility study of readout operation at 4 K for extended applications. To increase resonant Q at 4 K and maintain low-noise SQUID operation, multiplexer chips consisting of niobium nitride (NbN)-based coplanar-waveguide resonators and niobium (Nb)-based RF-SQUIDs have been developed. This hybrid multiplexer exhibited 1×104≤QI≤2×104 and the square root of spectral density of current noise referred to the SQUID input √SI =31 pA/√Hz, where QI is the internal Q of resonators. The former and the latter are factor-of-five and seven improvements from our previous results on Nb-based resonators, respectively. Systematic noise measurement with various microwave readout power PMR and two-directional readout on the complex plane of transmission component of scattering matrix S21 makes the contribution of each noise source obvious. By decreasing these noises to the degree achievable by current technology, we predicted the microwave RF-SQUID multiplexer would exhibit √SI ≤5 pA/√Hz; i.e., close to √SI of state-of-the-art DC-SQUID-based multiplexers.

TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)•Jan 1, 2004•0 citations
Abstract Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of 1.4 pA/Hz1.4\,{{{\rm{pA}}}}/\sqrt{{{{\rm{Hz}}}}}1.4pA/Hz​ 1.4 pA / Hz , considerably below the detector noise at frequencies of interest, and an energy resolution of (0.137 ± 0.001) eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.
We describe a novel class of devices based on the nonlinearity of the kinetic inductance of a superconducting thin film. By placing a current-dependent inductance in a microwave resonator, small currents can be measured through their effect on the resonator’s frequency. By using a high-resistivity material for the film and nanowires as kinetic inductors, we can achieve a large coefficient of nonlinearity to improve device sensitivity. We demonstrate a current sensitivity of 8 pA/√Hz, making this device useful for transition-edge sensor (TES) readout and other cutting-edge applications. An advantage of these devices is their natural ability to be multiplexed in the frequency domain, enabling large detector arrays for TES-based instruments. A traveling-wave version of the device, consisting of a thin-film microwave transmission line, is also sensitive to small currents as they change the phase length of the line due to their effect on its inductance. We demonstrate a current sensitivity of 5 pA/√Hz for this version of the device, making it also suitable for TES readout as well as other current-detection applications. It has the advantage of multi-gigahertz bandwidth and greater dynamic range, offering a different approach to the resonator version of the device. Finally, we also demonstrate a transmission-line resonator version of the device that combines some of the advantages of the nanowire resonator and the traveling-wave device. This version of the device has high dynamic range but can also be easily multiplexed in the frequency domain. A lumped-element resonator similar to the first device can be placed in a loop configuration to make it sensitive to magnetic fields. We demonstrate an example of such a device whose sensitivity could ultimately reach levels similar to those of state-of-the-art DC SQUIDs, making it potentially useful for many magnetometry applications given its ease of multiplexing. Finally, a similar microwave resonator is shown to exhibit parametric gain of up to 29 dB in the presence of a strong pump tone. The noise performance of this parametric amplifier approaches the quantum limit, making it useful for applications in quantum information and metrology.
We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range for large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4 nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art current readout approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured can directly be injected without having the need of an impedance matching circuit, reducing the system complexity. With the proof-of-concept device we measured a current noise floor δI min of 10 pA/Hz 1/2 at 10 kHz. Furthermore, we demonstrate the ability of our sensor to amplify a pulsed response of a superconducting nanowire single-photon detector using a GHz-range carrier for effective frequency-division multiplexing.
We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range of large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4-nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured can directly be injected without having the need of an impedance matching circuit, reducing the system complexity. With the proof-of-concept device we measured a current noise floor δImin of 10 pA/Hz1/2 at 10 kHz. Furthermore, we demonstrate the ability of our sensor to amplify a pulsed response of a superconducting nanowire single-photon detector using a GHz-range carrier for effective frequency-division multiplexing.
Superconducting microcalorimeter arrays with hundreds to thousands of pixels are enabling new measurements and capabilities in exotic atom spectroscopy, x-ray astronomy, nuclear materials analysis, and many other fields. We consider the prospects of multiplexing microcalorimeters with the kinetic inductance current sensor (KICS), an alternative to the superconducting quantum interference device (SQUID) historically used to read out cryogenic microcalorimeters. We show that the amplifier limited noise of the KICS is determined by its dynamic range, which is a free design parameter and tuneable with a DC current bias. We predict that KICS can meet the requirements to read out prototype metallic magnetic calorimeter (MMC) pixels designed for the Lynx x-ray satellite mission concept with the use of low-latency tone tracking. We propose a KICS design that has both high coupling efficiency and high isolation between the RF and DC components of the circuit. We argue that the KICS provides engineering trade-offs that are better suited to the readout of microcalorimeters when compared to the analogous microwave SQUID multiplexer.
We report on the design and performance of microwave kinetic inductance detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 μΩ cm with RRR=1.6. Resonators on the device displayed internal quality factors of around 200 000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process, which resulted in pixels with decay times of about 40 μs and resolving powers of ∼9 at 800 nm.
Dissipationless microwave radio frequency superconducting interference device (RF-SQUID) multiplexers are attractive for readouts of large format arrays of transition edge sensors (TES). This multiplexer has the potential for readout bandwidth of several GHz and power consumption of ≈0.1 pW per pixel, which are ≈103 and ≈10-4 times as large as those of DC-SQUID-based conventional multiplexers. To evaluate their readout performance for TES photon counters ranging from near infrared to gamma ray, white noise of this multiplexer was experimentally studied at 4 K. The reason for this was, firstly, to avoid the low-frequency fluctuation obvious at around 0.1 K but trivial for the energy resolution of photon counters, and secondly for a feasibility study of readout operation at 4 K for extended applications. To increase resonant Q at 4 K and maintain low-noise SQUID operation, multiplexer chips consisting of niobium nitride (NbN)-based coplanar-waveguide resonators and niobium (Nb)-based RF-SQUIDs have been developed. This hybrid multiplexer exhibited 1×104≤QI≤2×104 and the square root of spectral density of current noise referred to the SQUID input √SI =31 pA/√Hz, where QI is the internal Q of resonators. The former and the latter are factor-of-five and seven improvements from our previous results on Nb-based resonators, respectively. Systematic noise measurement with various microwave readout power PMR and two-directional readout on the complex plane of transmission component of scattering matrix S21 makes the contribution of each noise source obvious. By decreasing these noises to the degree achievable by current technology, we predicted the microwave RF-SQUID multiplexer would exhibit √SI ≤5 pA/√Hz; i.e., close to √SI of state-of-the-art DC-SQUID-based multiplexers.