Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Superconducting Nonlinear Kinetic Inductance Devices

Kher, Aditya Shreyas

Published Feb 10, 2017• 17 citations
Publisher

Abstract

We describe a novel class of devices based on the nonlinearity of the kinetic inductance of a superconducting thin film. By placing a current-dependent inductance in a microwave resonator, small currents can be measured through their effect on the resonator’s frequency. By using a high-resistivity material for the film and nanowires as kinetic inductors, we can achieve a large coefficient of nonlinearity to improve device sensitivity. We demonstrate a current sensitivity of 8 pA/√Hz, making this device useful for transition-edge sensor (TES) readout and other cutting-edge applications. An advantage of these devices is their natural ability to be multiplexed in the frequency domain, enabling large detector arrays for TES-based instruments. A traveling-wave version of the device, consisting of a thin-film microwave transmission line, is also sensitive to small currents as they change the phase length of the line due to their effect on its inductance. We demonstrate a current sensitivity of 5 pA/√Hz for this version of the device, making it also suitable for TES readout as well as other current-detection applications. It has the advantage of multi-gigahertz bandwidth and greater dynamic range, offering a different approach to the resonator version of the device. Finally, we also demonstrate a transmission-line resonator version of the device that combines some of the advantages of the nanowire resonator and the traveling-wave device. This version of the device has high dynamic range but can also be easily multiplexed in the frequency domain. A lumped-element resonator similar to the first device can be placed in a loop configuration to make it sensitive to magnetic fields. We demonstrate an example of such a device whose sensitivity could ultimately reach levels similar to those of state-of-the-art DC SQUIDs, making it potentially useful for many magnetometry applications given its ease of multiplexing. Finally, a similar microwave resonator is shown to exhibit parametric gain of up to 29 dB in the presence of a strong pump tone. The noise performance of this parametric amplifier approaches the quantum limit, making it useful for applications in quantum information and metrology.

DOI
10.7907/z9jq0z1f

Related papers

Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout

Paul Szypryt, D. A. Bennett, I. M. Fogarty Florang +12 more

Abstract Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of $$1.4\,{{{\rm{pA}}}}/\sqrt{{{{\rm{Hz}}}}}$$ 1.4 pA / Hz , considerably below the detector noise at frequencies of interest, and an energy resolution of (0.137 ± 0.001) eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.

arXiv:2405.15017•Communications Engineering•Nov 6, 2024•17 citations

Development of an Array of Kinetic Inductance Magnetometers (KIMs)

Sasha Sypkens, Farzad Faramarzi, Marco Colangelo +6 more

We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux through the inductive loop. A perturbing signal will cause a flux change through the loop, and thus a change in the induced current, which alters the kinetic inductance of the nanowires, causing the resonant frequency of the KIM to shift. This technology has applications in astrophysics, material science, and the medical field for readout of Metallic Magnetic Calorimeters (MMCs), axion detection, and magnetoencephalography (MEG).

arXiv:2102.11001•IEEE Transactions on Applied Superconductivity•Feb 3, 2021•3 citations

Kinetic Inductance Traveling Wave Amplifier Designs for Practical Microwave Readout Applications

Andrea Giachero, Michael R. Vissers, Jordan Wheeler +6 more

Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.

arXiv:2403.11354•Journal of Low Temperature Physics•Apr 5, 2024•15 citations

SKIFFS: Superconducting Kinetic Inductance Field-Frequency Sensors for sensitive magnetometry in moderate background magnetic fields

Abraham T. Asfaw, Ethan Kleinbaum, Thomas Hazard +3 more

We describe sensitive magnetometry using lumped-element resonators fabricated from a superconducting thin film of NbTiN. Taking advantage of the large kinetic inductance of the superconductor, we demonstrate a continuous resonance frequency shift of 27 MHz for a change in the magnetic field of 1.8 μT within a perpendicular background field of 60 mT. By using phase-sensitive readout of microwaves transmitted through the sensors, we measure phase shifts in real time with a sensitivity of 1°/nT. We present measurements of the noise spectral density of the sensors and find that their field sensitivity is at least within one to two orders of magnitude of superconducting quantum interference devices operating with zero background field. Our superconducting kinetic inductance field-frequency sensors enable real-time magnetometry in the presence of moderate perpendicular background fields up to at least 0.2 T. Applications for our sensors include the stabilization of magnetic fields in long coherence electron spin resonance measurements and quantum computation.

arXiv:1807.09860•Applied Physics Letters•Oct 22, 2018•4 citations

Compact microwave kinetic inductance nanowire galvanometer for cryogenic detectors at 4.2 K

S Doerner, Artem A. Kuzmin, K Graf +3 more

We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range for large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4 nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art current readout approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured can directly be injected without having the need of an impedance matching circuit, reducing the system complexity. With the proof-of-concept device we measured a current noise floor δI min of 10 pA/Hz 1/2 at 10 kHz. Furthermore, we demonstrate the ability of our sensor to amplify a pulsed response of a superconducting nanowire single-photon detector using a GHz-range carrier for effective frequency-division multiplexing.

Journal of Physics Communications•Jan 25, 2018•8 citations

Compact microwave kinetic inductance nanowire galvanometer for cryogenic detectors at 4.2 K

Doerner, S., Artem A. Kuzmin, Graf, K. +3 more

We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range of large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4-nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured can directly be injected without having the need of an impedance matching circuit, reducing the system complexity. With the proof-of-concept device we measured a current noise floor δImin of 10 pA/Hz1/2 at 10 kHz. Furthermore, we demonstrate the ability of our sensor to amplify a pulsed response of a superconducting nanowire single-photon detector using a GHz-range carrier for effective frequency-division multiplexing.

arXiv:1709.02640•Sep 8, 2017•0 citations
We describe a novel class of devices based on the nonlinearity of the kinetic inductance of a superconducting thin film. By placing a current-dependent inductance in a microwave resonator, small currents can be measured through their effect on the resonator’s frequency. By using a high-resistivity material for the film and nanowires as kinetic inductors, we can achieve a large coefficient of nonlinearity to improve device sensitivity. We demonstrate a current sensitivity of 8 pA/√Hz, making this device useful for transition-edge sensor (TES) readout and other cutting-edge applications. An advantage of these devices is their natural ability to be multiplexed in the frequency domain, enabling large detector arrays for TES-based instruments. A traveling-wave version of the device, consisting of a thin-film microwave transmission line, is also sensitive to small currents as they change the phase length of the line due to their effect on its inductance. We demonstrate a current sensitivity of 5 pA/√Hz for this version of the device, making it also suitable for TES readout as well as other current-detection applications. It has the advantage of multi-gigahertz bandwidth and greater dynamic range, offering a different approach to the resonator version of the device. Finally, we also demonstrate a transmission-line resonator version of the device that combines some of the advantages of the nanowire resonator and the traveling-wave device. This version of the device has high dynamic range but can also be easily multiplexed in the frequency domain. A lumped-element resonator similar to the first device can be placed in a loop configuration to make it sensitive to magnetic fields. We demonstrate an example of such a device whose sensitivity could ultimately reach levels similar to those of state-of-the-art DC SQUIDs, making it potentially useful for many magnetometry applications given its ease of multiplexing. Finally, a similar microwave resonator is shown to exhibit parametric gain of up to 29 dB in the presence of a strong pump tone. The noise performance of this parametric amplifier approaches the quantum limit, making it useful for applications in quantum information and metrology.
Abstract Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale spectroscopic imaging or photonic quantum computing applications, the size of visible to near-infrared transition-edge sensor arrays and their associated readouts must be increased from a few pixels to many thousands. In this manuscript, we introduce the kinetic inductance current sensor, a scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. Kinetic inductance current sensors can replace superconducting quantum interference devices for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a visible to near-infrared transition-edge sensor using a kinetic inductance current sensor with 3.7 MHz of bandwidth. We measure a readout noise of 1.4 pA/Hz1.4\,{{{\rm{pA}}}}/\sqrt{{{{\rm{Hz}}}}}1.4pA/Hz​ 1.4 pA / Hz , considerably below the detector noise at frequencies of interest, and an energy resolution of (0.137 ± 0.001) eV at 0.8 eV, comparable to resolutions observed with non-multiplexed superconducting quantum interference device readouts.
We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux through the inductive loop. A perturbing signal will cause a flux change through the loop, and thus a change in the induced current, which alters the kinetic inductance of the nanowires, causing the resonant frequency of the KIM to shift. This technology has applications in astrophysics, material science, and the medical field for readout of Metallic Magnetic Calorimeters (MMCs), axion detection, and magnetoencephalography (MEG).
Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.
We describe sensitive magnetometry using lumped-element resonators fabricated from a superconducting thin film of NbTiN. Taking advantage of the large kinetic inductance of the superconductor, we demonstrate a continuous resonance frequency shift of 27 MHz for a change in the magnetic field of 1.8 μT within a perpendicular background field of 60 mT. By using phase-sensitive readout of microwaves transmitted through the sensors, we measure phase shifts in real time with a sensitivity of 1°/nT. We present measurements of the noise spectral density of the sensors and find that their field sensitivity is at least within one to two orders of magnitude of superconducting quantum interference devices operating with zero background field. Our superconducting kinetic inductance field-frequency sensors enable real-time magnetometry in the presence of moderate perpendicular background fields up to at least 0.2 T. Applications for our sensors include the stabilization of magnetic fields in long coherence electron spin resonance measurements and quantum computation.
We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range for large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4 nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art current readout approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured can directly be injected without having the need of an impedance matching circuit, reducing the system complexity. With the proof-of-concept device we measured a current noise floor δI min of 10 pA/Hz 1/2 at 10 kHz. Furthermore, we demonstrate the ability of our sensor to amplify a pulsed response of a superconducting nanowire single-photon detector using a GHz-range carrier for effective frequency-division multiplexing.
We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range of large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4-nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured can directly be injected without having the need of an impedance matching circuit, reducing the system complexity. With the proof-of-concept device we measured a current noise floor δImin of 10 pA/Hz1/2 at 10 kHz. Furthermore, we demonstrate the ability of our sensor to amplify a pulsed response of a superconducting nanowire single-photon detector using a GHz-range carrier for effective frequency-division multiplexing.