Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2308.13603 · Optica Quantum

Number-state reconstruction with a single single-photon avalanche detector

Patrick Banner, Deniz Kurdak, Yaxin Li, Alan L. Migdall, J. V. Porto, S. L. Rolston

Published Mar 6, 2024• 8 citations
arXivHTMLPDF

Abstract

Single-photon avalanche detectors (SPADs) are crucial sensors of light for many fields and applications. However, they are not able to resolve photon number, so typically more complex and more expensive experimental setups or devices must be used to measure the number of photons in a pulse. Here, we present a methodology for performing photon number-state reconstruction with only one SPAD. The methodology, which is cost-effective and easy to implement, uses maximum-likelihood techniques with a detector model whose parameters are measurable. We achieve excellent agreement between known input pulses and their reconstructions for coherent states with up to ≈10 photons and peak input photon rates up to several Mcounts/s. When detector imperfections are small, we maintain good agreement for coherent pulses with peak input photon rates of over 40 Mcounts/s, greater than one photon per detector dead time. For anti-bunched light, the reconstructed and independently measured pulse-averaged values of g (2) (0) are also consistent with one another. Our algorithm is applicable to light pulses whose pulse width and correlation time scales are both at least a few detector dead times. These results, achieved with single commercially available SPADs, provide an inexpensive number-state reconstruction method and expand the capabilities of single-photon detectors.

DOI
10.1364/opticaq.504308

Related papers

Number-state reconstruction with a single SPAD

Patrick Banner, Deniz Kurdak, Yaxin Li +3 more

Single-photon avalanche detectors (SPADs) are used ubiquitously in optical and quantum science, but they are not photon-number-resolving detectors. Despite this, in this work we present preliminary results that show that a single SPAD can still be used to perform number-state reconstruction. Through detector characterization and use of maximum-likelihood analysis, we perform number-state reconstruction with a single SPAD and obtain good agreement with independently measured distributions for both Poissonian and anti-bunched light. Our method works well for photon rates up to roughly one input photon per dead time as well as pulse lengths and correlation times of at least a few dead times, fitting many of today’s quantum optics experiments.

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

Fiber-assisted detection with photon number resolution

Daryl Achilles, Christine Silberhorn, Cezary Śliwa +2 more

We report the development of a photon-number-resolving detector based on a fiber-optical setup and a pair of standard avalanche photodiodes. The detector is capable of resolving individual photon numbers and operates on the well-known principle by which a single-mode input state is split into a large number (eight) of output modes. We reconstruct the photon statistics of weak coherent input light from experimental data and show that there is a high probability of inferring the input photon number from a measurement of the number of detection events on a single run.

arXiv:quant-ph/0305191•Optics Letters•Dec 1, 2003•294 citations

Photon-number resolution using time-multiplexed single-photon detectors

Michael J. Fitch, B. C. Jacobs, T. B. Pittman +1 more

Photon-number-resolving detectors are needed for a variety of applications including linear-optics quantum computing. Here we describe the use of time-multiplexing techniques that allow ordinary single-photon detectors, such as silicon avalanche photodiodes, to be used as photon-number-resolving detectors. The ability of such a detector to correctly measure the number of photons for an incident number state is analyzed. The predicted results for an incident coherent state are found to be in good agreement with the results of a proof-of-principle experimental demonstration.

arXiv:quant-ph/0305193•Physical Review A•Oct 10, 2003•351 citations

Reconstruction of photon-number distribution using low-performance photon counters

Guido Zambra, Matteo G. A. Paris

The output of a photodetector consists of a current pulse whose charge has the statistical distribution of the actual photon numbers convolved with a Bernoulli distribution. Photodetectors are characterized by a nonunit quantum efficiency, i.e., not all the photons lead to a charge, and by a finite resolution, i.e., a different number of detected photons leads to a discriminable values of the charge only up to a maximum value. We present a detailed comparison, based on Monte Carlo simulated experiments and real data, among the performances of detectors with different upper limits of counting capability. In our scheme the inversion of Bernoulli convolution is performed by maximum-likelihood methods assisted by measurements taken at different quantum efficiencies. We show that detectors that are only able to discriminate between zero, one and more than one detected photons are generally enough to provide a reliable reconstruction of the photon number distribution for single-peaked distributions, while detectors with higher resolution limits do not lead to further improvements. In addition, we demonstrate that, for semiclassical states, even on/off detectors are enough to provide a good reconstruction. Finally, we show that a reliable reconstruction of multipeaked distributions requires either higher quantum efficiency or higher resolution.

arXiv:quant-ph/0607052•Physical Review A•Dec 27, 2006•23 citations

A study to develop a robust method for measuring the detection efficiency of free-running InGaAs/InP single-photon detectors

Marco López, Alice Meda, Geiland Porrovecchio +7 more

Abstract The challenges faced in a comparison of measuring the detection efficiency of free-running InGaAs/InP single-photon avalanche detectors (InGaAs/InP SPAD) were studied by four European National Metrology Institutes (NMIs) meeting at a single laboratory. The main purpose of this study is to develop a trustable measurement technique and to provide a snapshot of the methods used by the four NMIs for measuring such photon-counting detectors at telecom wavelengths in order to establish proper procedures for characterising such devices. The detection efficiency measurements were performed using different experimental setups and reference standards with independent traceability chains at the wavelength of 1550 nm. A dedicated model to correct the dead time and dark count effects on the SPAD’s free-running counting process was developed, allowing the correct value of the photon rate impinging on the detector to be recovered from simple ratemeter measurements. The detection efficiency was measured for mean photon number per pulse between 0.01 and 2.4, corresponding to photon rates between approximately 1100 photon/s and 193,000 photon/s, respectively. We found that the measured values reported by the participants are all consistent within the stated uncertainties, proving the consistency of the measurement approach developed.

EPJ Quantum Technology•Nov 25, 2020•13 citations

Measuring the photon distribution with ON/OFF photodetectors

Marco Genovese, Marco Gramegna, G. Brida +5 more

Reconstruction of photon statistics of optical states provides fundamental information on the nature of any optical field and helps with various relevant applications. Nevertheless, no detector that can reliably discriminate the number of incident photons is available. On the other hand, the alternative of reconstructing the density matrix by quantum tomography leads to various technical difficulties that are particularly severe in the pulsed regime (where mode matching between a signal and local oscillator is very challenging). Even if on/off detectors, as usual avalanche photodiodes operating in Geiger mode, seem useless as photo-counters, it was recently shown how reconstruction of photon statistics is possible by considering a variable quantum efficiency. Here we present experimental reconstructions of photon number distributions of both continuous-wave and pulsed light beams in a scheme based on on/off avalanche photodetection assisted by maximum-likelihood estimation. Reconstructions of the distribution for both semiclassical and quantum states of light (as single photon, coherent, pseudothermal, and multithermal states) are reported for single-mode and multimode beams. The stability and good accuracy obtained in the reconstruction of these states clearly demonstrate the interesting potentialities of this simple technique.

arXiv:quant-ph/0601175•Laser Physics•Feb 1, 2006•32 citations
Single-photon avalanche detectors (SPADs) are crucial sensors of light for many fields and applications. However, they are not able to resolve photon number, so typically more complex and more expensive experimental setups or devices must be used to measure the number of photons in a pulse. Here, we present a methodology for performing photon number-state reconstruction with only one SPAD. The methodology, which is cost-effective and easy to implement, uses maximum-likelihood techniques with a detector model whose parameters are measurable. We achieve excellent agreement between known input pulses and their reconstructions for coherent states with up to ≈10 photons and peak input photon rates up to several Mcounts/s. When detector imperfections are small, we maintain good agreement for coherent pulses with peak input photon rates of over 40 Mcounts/s, greater than one photon per detector dead time. For anti-bunched light, the reconstructed and independently measured pulse-averaged values of g (2) (0) are also consistent with one another. Our algorithm is applicable to light pulses whose pulse width and correlation time scales are both at least a few detector dead times. These results, achieved with single commercially available SPADs, provide an inexpensive number-state reconstruction method and expand the capabilities of single-photon detectors.
Single-photon avalanche detectors (SPADs) are used ubiquitously in optical and quantum science, but they are not photon-number-resolving detectors. Despite this, in this work we present preliminary results that show that a single SPAD can still be used to perform number-state reconstruction. Through detector characterization and use of maximum-likelihood analysis, we perform number-state reconstruction with a single SPAD and obtain good agreement with independently measured distributions for both Poissonian and anti-bunched light. Our method works well for photon rates up to roughly one input photon per dead time as well as pulse lengths and correlation times of at least a few dead times, fitting many of today’s quantum optics experiments.
We report the development of a photon-number-resolving detector based on a fiber-optical setup and a pair of standard avalanche photodiodes. The detector is capable of resolving individual photon numbers and operates on the well-known principle by which a single-mode input state is split into a large number (eight) of output modes. We reconstruct the photon statistics of weak coherent input light from experimental data and show that there is a high probability of inferring the input photon number from a measurement of the number of detection events on a single run.
Photon-number-resolving detectors are needed for a variety of applications including linear-optics quantum computing. Here we describe the use of time-multiplexing techniques that allow ordinary single-photon detectors, such as silicon avalanche photodiodes, to be used as photon-number-resolving detectors. The ability of such a detector to correctly measure the number of photons for an incident number state is analyzed. The predicted results for an incident coherent state are found to be in good agreement with the results of a proof-of-principle experimental demonstration.
The output of a photodetector consists of a current pulse whose charge has the statistical distribution of the actual photon numbers convolved with a Bernoulli distribution. Photodetectors are characterized by a nonunit quantum efficiency, i.e., not all the photons lead to a charge, and by a finite resolution, i.e., a different number of detected photons leads to a discriminable values of the charge only up to a maximum value. We present a detailed comparison, based on Monte Carlo simulated experiments and real data, among the performances of detectors with different upper limits of counting capability. In our scheme the inversion of Bernoulli convolution is performed by maximum-likelihood methods assisted by measurements taken at different quantum efficiencies. We show that detectors that are only able to discriminate between zero, one and more than one detected photons are generally enough to provide a reliable reconstruction of the photon number distribution for single-peaked distributions, while detectors with higher resolution limits do not lead to further improvements. In addition, we demonstrate that, for semiclassical states, even on/off detectors are enough to provide a good reconstruction. Finally, we show that a reliable reconstruction of multipeaked distributions requires either higher quantum efficiency or higher resolution.
Abstract The challenges faced in a comparison of measuring the detection efficiency of free-running InGaAs/InP single-photon avalanche detectors (InGaAs/InP SPAD) were studied by four European National Metrology Institutes (NMIs) meeting at a single laboratory. The main purpose of this study is to develop a trustable measurement technique and to provide a snapshot of the methods used by the four NMIs for measuring such photon-counting detectors at telecom wavelengths in order to establish proper procedures for characterising such devices. The detection efficiency measurements were performed using different experimental setups and reference standards with independent traceability chains at the wavelength of 1550 nm. A dedicated model to correct the dead time and dark count effects on the SPAD’s free-running counting process was developed, allowing the correct value of the photon rate impinging on the detector to be recovered from simple ratemeter measurements. The detection efficiency was measured for mean photon number per pulse between 0.01 and 2.4, corresponding to photon rates between approximately 1100 photon/s and 193,000 photon/s, respectively. We found that the measured values reported by the participants are all consistent within the stated uncertainties, proving the consistency of the measurement approach developed.
Reconstruction of photon statistics of optical states provides fundamental information on the nature of any optical field and helps with various relevant applications. Nevertheless, no detector that can reliably discriminate the number of incident photons is available. On the other hand, the alternative of reconstructing the density matrix by quantum tomography leads to various technical difficulties that are particularly severe in the pulsed regime (where mode matching between a signal and local oscillator is very challenging). Even if on/off detectors, as usual avalanche photodiodes operating in Geiger mode, seem useless as photo-counters, it was recently shown how reconstruction of photon statistics is possible by considering a variable quantum efficiency. Here we present experimental reconstructions of photon number distributions of both continuous-wave and pulsed light beams in a scheme based on on/off avalanche photodetection assisted by maximum-likelihood estimation. Reconstructions of the distribution for both semiclassical and quantum states of light (as single photon, coherent, pseudothermal, and multithermal states) are reported for single-mode and multimode beams. The stability and good accuracy obtained in the reconstruction of these states clearly demonstrate the interesting potentialities of this simple technique.