Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0607052 · Physical Review A

Reconstruction of photon-number distribution using low-performance photon counters

Guido Zambra, Matteo G. A. Paris

Published Dec 27, 2006• 23 citations
arXivHTMLPDF

Abstract

The output of a photodetector consists of a current pulse whose charge has the statistical distribution of the actual photon numbers convolved with a Bernoulli distribution. Photodetectors are characterized by a nonunit quantum efficiency, i.e., not all the photons lead to a charge, and by a finite resolution, i.e., a different number of detected photons leads to a discriminable values of the charge only up to a maximum value. We present a detailed comparison, based on Monte Carlo simulated experiments and real data, among the performances of detectors with different upper limits of counting capability. In our scheme the inversion of Bernoulli convolution is performed by maximum-likelihood methods assisted by measurements taken at different quantum efficiencies. We show that detectors that are only able to discriminate between zero, one and more than one detected photons are generally enough to provide a reliable reconstruction of the photon number distribution for single-peaked distributions, while detectors with higher resolution limits do not lead to further improvements. In addition, we demonstrate that, for semiclassical states, even on/off detectors are enough to provide a good reconstruction. Finally, we show that a reliable reconstruction of multipeaked distributions requires either higher quantum efficiency or higher resolution.

DOI
10.1103/physreva.74.063830

Related papers

Photon Statistics by Low Resolution-Threshold Photodetectors

Guido Zambra, Alessia Allevi, Maria Bondani +2 more

Maximum-likelihood method allows the reconstruction of single-peaked photon statistics by using realistic photodetectors having low quantum efficiencies and discriminating between zero, one and more than one detected photons. Higher efficiencies are needed for multi-peaked statistics.

European Conference on Optical Communication•Sep 1, 2006•0 citations

Measuring the photon distribution with ON/OFF photodetectors

Marco Genovese, Marco Gramegna, G. Brida +5 more

Reconstruction of photon statistics of optical states provides fundamental information on the nature of any optical field and helps with various relevant applications. Nevertheless, no detector that can reliably discriminate the number of incident photons is available. On the other hand, the alternative of reconstructing the density matrix by quantum tomography leads to various technical difficulties that are particularly severe in the pulsed regime (where mode matching between a signal and local oscillator is very challenging). Even if on/off detectors, as usual avalanche photodiodes operating in Geiger mode, seem useless as photo-counters, it was recently shown how reconstruction of photon statistics is possible by considering a variable quantum efficiency. Here we present experimental reconstructions of photon number distributions of both continuous-wave and pulsed light beams in a scheme based on on/off avalanche photodetection assisted by maximum-likelihood estimation. Reconstructions of the distribution for both semiclassical and quantum states of light (as single photon, coherent, pseudothermal, and multithermal states) are reported for single-mode and multimode beams. The stability and good accuracy obtained in the reconstruction of these states clearly demonstrate the interesting potentialities of this simple technique.

arXiv:quant-ph/0601175•Laser Physics•Feb 1, 2006•32 citations

NONTRIVIAL PHOTON STATISTICS WITH LOW RESOLUTION-THRESHOLD PHOTON COUNTERS

Guido Zambra, Alessia Allevi, Alessandra Andreoni +2 more

We address the reconstruction of photon statistics using realistic photodetectors having low quantum efficiency and finite resolution as photon counters. Using a maximum-likelihood method, based on measurements taken at different quantum efficiencies, we experimentally reconstruct the nontrivial photon statistics of the state obtained by mixing at a beam-splitter two phase-averaged coherent states. The effect of using different resolution thresholds is also discussed.

International Journal of Quantum Information•Feb 1, 2007•13 citations

Towards photostatistics from photon-number discriminating detectors

Hwang Lee, Ulvi Yurtsever, Pieter Kok +4 more

We study the properties of a photodetector that has a numberresolving capability. In the absence of dark counts, due to its finite quantum efficiency, photodetection with such a detector can only eliminate the possibility that the incident field corresponds to a number of photons less than the detected photon number. We show that such a non-photon number-discriminating detector, however, provides a useful tool in the reconstruction of the photon number distribution of the incident field even in the presence of dark counts.

arXiv:quant-ph/0310161•Journal of Modern Optics•Jan 1, 2004•48 citations

Experimental Reconstruction of Photon Statistics without Photon Counting

Guido Zambra, Alessandra Andreoni, Maria Bondani +5 more

Experimental reconstructions of photon number distributions of both continuous-wave and pulsed light beams are reported. Our scheme is based on on/off avalanche photo-detection assisted by maximum-likelihood estimation and does not involve photon counting. Reconstructions of the distribution for both semiclassical and quantum states of light are reported for single-mode as well as for multi-mode beams.

arXiv:quant-ph/0502060•Physical Review Letters•Aug 5, 2005•167 citations

Number-state reconstruction with a single single-photon avalanche detector

Patrick Banner, Deniz Kurdak, Yaxin Li +3 more

Single-photon avalanche detectors (SPADs) are crucial sensors of light for many fields and applications. However, they are not able to resolve photon number, so typically more complex and more expensive experimental setups or devices must be used to measure the number of photons in a pulse. Here, we present a methodology for performing photon number-state reconstruction with only one SPAD. The methodology, which is cost-effective and easy to implement, uses maximum-likelihood techniques with a detector model whose parameters are measurable. We achieve excellent agreement between known input pulses and their reconstructions for coherent states with up to ≈10 photons and peak input photon rates up to several Mcounts/s. When detector imperfections are small, we maintain good agreement for coherent pulses with peak input photon rates of over 40 Mcounts/s, greater than one photon per detector dead time. For anti-bunched light, the reconstructed and independently measured pulse-averaged values of g (2) (0) are also consistent with one another. Our algorithm is applicable to light pulses whose pulse width and correlation time scales are both at least a few detector dead times. These results, achieved with single commercially available SPADs, provide an inexpensive number-state reconstruction method and expand the capabilities of single-photon detectors.

arXiv:2308.13603•Optica Quantum•Mar 6, 2024•8 citations
The output of a photodetector consists of a current pulse whose charge has the statistical distribution of the actual photon numbers convolved with a Bernoulli distribution. Photodetectors are characterized by a nonunit quantum efficiency, i.e., not all the photons lead to a charge, and by a finite resolution, i.e., a different number of detected photons leads to a discriminable values of the charge only up to a maximum value. We present a detailed comparison, based on Monte Carlo simulated experiments and real data, among the performances of detectors with different upper limits of counting capability. In our scheme the inversion of Bernoulli convolution is performed by maximum-likelihood methods assisted by measurements taken at different quantum efficiencies. We show that detectors that are only able to discriminate between zero, one and more than one detected photons are generally enough to provide a reliable reconstruction of the photon number distribution for single-peaked distributions, while detectors with higher resolution limits do not lead to further improvements. In addition, we demonstrate that, for semiclassical states, even on/off detectors are enough to provide a good reconstruction. Finally, we show that a reliable reconstruction of multipeaked distributions requires either higher quantum efficiency or higher resolution.
Reconstruction of photon statistics of optical states provides fundamental information on the nature of any optical field and helps with various relevant applications. Nevertheless, no detector that can reliably discriminate the number of incident photons is available. On the other hand, the alternative of reconstructing the density matrix by quantum tomography leads to various technical difficulties that are particularly severe in the pulsed regime (where mode matching between a signal and local oscillator is very challenging). Even if on/off detectors, as usual avalanche photodiodes operating in Geiger mode, seem useless as photo-counters, it was recently shown how reconstruction of photon statistics is possible by considering a variable quantum efficiency. Here we present experimental reconstructions of photon number distributions of both continuous-wave and pulsed light beams in a scheme based on on/off avalanche photodetection assisted by maximum-likelihood estimation. Reconstructions of the distribution for both semiclassical and quantum states of light (as single photon, coherent, pseudothermal, and multithermal states) are reported for single-mode and multimode beams. The stability and good accuracy obtained in the reconstruction of these states clearly demonstrate the interesting potentialities of this simple technique.
We study the properties of a photodetector that has a numberresolving capability. In the absence of dark counts, due to its finite quantum efficiency, photodetection with such a detector can only eliminate the possibility that the incident field corresponds to a number of photons less than the detected photon number. We show that such a non-photon number-discriminating detector, however, provides a useful tool in the reconstruction of the photon number distribution of the incident field even in the presence of dark counts.
Single-photon avalanche detectors (SPADs) are crucial sensors of light for many fields and applications. However, they are not able to resolve photon number, so typically more complex and more expensive experimental setups or devices must be used to measure the number of photons in a pulse. Here, we present a methodology for performing photon number-state reconstruction with only one SPAD. The methodology, which is cost-effective and easy to implement, uses maximum-likelihood techniques with a detector model whose parameters are measurable. We achieve excellent agreement between known input pulses and their reconstructions for coherent states with up to ≈10 photons and peak input photon rates up to several Mcounts/s. When detector imperfections are small, we maintain good agreement for coherent pulses with peak input photon rates of over 40 Mcounts/s, greater than one photon per detector dead time. For anti-bunched light, the reconstructed and independently measured pulse-averaged values of g (2) (0) are also consistent with one another. Our algorithm is applicable to light pulses whose pulse width and correlation time scales are both at least a few detector dead times. These results, achieved with single commercially available SPADs, provide an inexpensive number-state reconstruction method and expand the capabilities of single-photon detectors.