Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2306.01884

Experimental analysis on image resolution of quantum imaging with undetected light through position correlations

Marta Gilaberte Basset, René Sondenheimer, Jorge Fuenzalida, Andres Vega, Sebastian Töpfer, Elkin A. Santos, Sina Saravi, Frank Setzpfandt, Fabian Steinlechner, Markus Gräfe

Published Jun 2, 2023• 0 citations
arXivHTMLPDF

Abstract

Image resolution of quantum imaging with undetected photons is governed by the spatial correlations existing between the photons of a photon pair that has been generated in a nonlinear process. These correlations allow for obtaining an image of an object with light that never interacted with that object. Depending on the imaging configuration, either position or momentum correlations are exploited. We hereby experimentally analyse how the crystal length and pump waist affect the image resolution when using position correlations of photons that have been generated via spontaneous parametric down conversion in a nonlinear interferometer. Our results support existing theoretical models for the dependency of the resolution on the crystal length. In addition, we probe the resolution of our quantum imaging scheme for varying pump waists over one order of magnitude. This analysis reveals the intricate dependency of the resolution on the strength of the correlations within the biphoton states for parameter combinations in which the crystal lengths are much larger than the involved photon wavelengths. We extend the existing models in this parameter regime to properly take nontrivial effects of finite pump waists into account and demonstrate that they match the experimental results.

DOI
10.48550/arxiv.2306.01884

Related papers

Experimental analysis of image resolution of quantum imaging with undetected light through position correlations

Marta Gilaberte Basset, René Sondenheimer, Jorge Fuenzalida +7 more

The authors explore the resolution dependency of imaging with undetected light, specifically the connection between spatial resolution and the strength of position correlations of SPDC-generated photons. Their results show a discrepancy from theoretical models, so they introduce an extended model that better takes image resolution into account.

Physical Review A•Nov 20, 2023•23 citations

Resolution of Quantum Imaging with Undetected Photons

Jorge Fuenzalida, Evelyn A. Ortega, Mayukh Lahiri +4 more

Quantum imaging with undetected photons is a recently introduced technique that goes significantly beyond what was previously possible.In this technique, images are formed without detecting the light that interacted with the object that is imaged.Given this unique advantage over the existing imaging schemes, it is now of utmost importance to understand its resolution limits, in particular what governs the maximal achievable spatial resolution.We show both theoretically and experimentally that the momentum correlation between the detected and undetected photons governs the spatial resolution -a stronger correlation results in a higher resolution.In our experiment, the momentum correlation plays the dominating role in determining the resolution compared to the effect of diffraction.We find that the resolution is determined by the wavelength of the undetected light rather than the wavelength of the detected light.Our results thus show that it is in principle possible to obtain resolution characterized by a wavelength much shorter than the detected wavelength.

•Jan 1, 2022•48 citations

Image resolution limit optimization for quantum imaging with undetected light

Marta Gilaberte Basset, Valerio Flavio Gili, René Sondenheimer

Quantum imaging with undetected light (QIUL) is a technique with great potential for imaging applications where extreme wavelengths are required to illuminate the object and, in particular, when low light intensities are crucial to not damage or modify the sample under study. This technique is based on the concept of induced coherence and makes use of spatial correlations. Therefore, either momentum or position correlations can be exploited by constructing a suitable system to access them. Depending on the selected configuration, image resolution is differently governed by the parameters of the quantum imaging source, e.g. crystal length, pump waist, and the down-converted wavelengths. Here, we present a tool to optimize the resolution limit of the imaging system given a specific application.

Optical and Quantum Sensing and Precision Metrology II•Mar 19, 2025•1 citation

Resolution of Quantum Imaging with Undetected Photons

Jorge Fuenzalida, Armin Hochrainer, Gabriela Barreto Lemos +4 more

Quantum imaging with undetected photons is a recently introduced technique that goes significantly beyond what was previously possible. In this technique, images are formed without detecting the light that interacted with the object that is imaged. Given this unique advantage over the existing imaging schemes, it is now of utmost importance to understand its resolution limits, in particular what governs the maximal achievable spatial resolution. We show both theoretically and experimentally that the momentum correlation between the detected and undetected photons governs the spatial resolution — a stronger correlation results in a higher resolution. In our experiment, the momentum correlation plays the dominating role in determining the resolution compared to the effect of diffraction. We find that the resolution is determined by the wavelength of the undetected light rather than the wavelength of the detected light. Our results thus show that it is in principle possible to obtain resolution characterized by a wavelength much shorter than the detected wavelength.

arXiv:2010.07712•Quantum•Feb 9, 2022•3 citations

Fundamental resolution limit of quantum imaging with undetected photons

Andres Vega, Elkin A. Santos, Jorge Fuenzalida +5 more

Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows us to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this nonlocal imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other nonlocal two-photon imaging schemes.

arXiv:2203.06106•Physical Review Research•Sep 30, 2022•28 citations

Mid-infrared microscopy via position correlations of undetected photons

Inna Kviatkovsky, Helen M. Chrzanowski, Sven Ramelow

Quantum imaging with undetected photons (QIUP) has recently emerged as a new powerful imaging tool. Exploiting the spatial entanglement of photon pairs, it allows decoupling of the sensing and detection wavelengths, facilitating imaging in otherwise challenging spectral regions by leveraging mature silicon-based detection technology. All existing implementations of QIUP have so far utilised the momentum correlations within the biphoton states produced by spontaneous parametric downconversion. Here, for the first time, we implement and examine theoretically and numerically the complementary scenario - utilising the tight position correlations formed within photon pairs at birth. This image plane arrangement facilitates high resolution imaging with comparative experimental ease, and we experimentally show resolutions below 10 μm at a sensing wavelength of 3.7 μm. Moreover, we present a quantitative numerical model predicting the imaging capabilities of QIUP for a wide range of parameters. Finally, by imaging mouse heart tissue at the mid-IR to reveal morphological features on the cellular level, we further demonstrate the viability of this technique for the life sciences. These results offer new perspectives on the capabilities of QIUP for label-free widefield mid-IR microscopy, enabling real-world biomedical as well as industrial imaging applications.

arXiv:2106.06435•Optics Express•Dec 13, 2021•40 citations
Image resolution of quantum imaging with undetected photons is governed by the spatial correlations existing between the photons of a photon pair that has been generated in a nonlinear process. These correlations allow for obtaining an image of an object with light that never interacted with that object. Depending on the imaging configuration, either position or momentum correlations are exploited. We hereby experimentally analyse how the crystal length and pump waist affect the image resolution when using position correlations of photons that have been generated via spontaneous parametric down conversion in a nonlinear interferometer. Our results support existing theoretical models for the dependency of the resolution on the crystal length. In addition, we probe the resolution of our quantum imaging scheme for varying pump waists over one order of magnitude. This analysis reveals the intricate dependency of the resolution on the strength of the correlations within the biphoton states for parameter combinations in which the crystal lengths are much larger than the involved photon wavelengths. We extend the existing models in this parameter regime to properly take nontrivial effects of finite pump waists into account and demonstrate that they match the experimental results.
Quantum imaging with undetected photons is a recently introduced technique that goes significantly beyond what was previously possible.In this technique, images are formed without detecting the light that interacted with the object that is imaged.Given this unique advantage over the existing imaging schemes, it is now of utmost importance to understand its resolution limits, in particular what governs the maximal achievable spatial resolution.We show both theoretically and experimentally that the momentum correlation between the detected and undetected photons governs the spatial resolution -a stronger correlation results in a higher resolution.In our experiment, the momentum correlation plays the dominating role in determining the resolution compared to the effect of diffraction.We find that the resolution is determined by the wavelength of the undetected light rather than the wavelength of the detected light.Our results thus show that it is in principle possible to obtain resolution characterized by a wavelength much shorter than the detected wavelength.
Quantum imaging with undetected light (QIUL) is a technique with great potential for imaging applications where extreme wavelengths are required to illuminate the object and, in particular, when low light intensities are crucial to not damage or modify the sample under study. This technique is based on the concept of induced coherence and makes use of spatial correlations. Therefore, either momentum or position correlations can be exploited by constructing a suitable system to access them. Depending on the selected configuration, image resolution is differently governed by the parameters of the quantum imaging source, e.g. crystal length, pump waist, and the down-converted wavelengths. Here, we present a tool to optimize the resolution limit of the imaging system given a specific application.
Quantum imaging with undetected photons is a recently introduced technique that goes significantly beyond what was previously possible. In this technique, images are formed without detecting the light that interacted with the object that is imaged. Given this unique advantage over the existing imaging schemes, it is now of utmost importance to understand its resolution limits, in particular what governs the maximal achievable spatial resolution. We show both theoretically and experimentally that the momentum correlation between the detected and undetected photons governs the spatial resolution — a stronger correlation results in a higher resolution. In our experiment, the momentum correlation plays the dominating role in determining the resolution compared to the effect of diffraction. We find that the resolution is determined by the wavelength of the undetected light rather than the wavelength of the detected light. Our results thus show that it is in principle possible to obtain resolution characterized by a wavelength much shorter than the detected wavelength.
Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows us to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this nonlocal imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other nonlocal two-photon imaging schemes.
Quantum imaging with undetected photons (QIUP) has recently emerged as a new powerful imaging tool. Exploiting the spatial entanglement of photon pairs, it allows decoupling of the sensing and detection wavelengths, facilitating imaging in otherwise challenging spectral regions by leveraging mature silicon-based detection technology. All existing implementations of QIUP have so far utilised the momentum correlations within the biphoton states produced by spontaneous parametric downconversion. Here, for the first time, we implement and examine theoretically and numerically the complementary scenario - utilising the tight position correlations formed within photon pairs at birth. This image plane arrangement facilitates high resolution imaging with comparative experimental ease, and we experimentally show resolutions below 10 μm at a sensing wavelength of 3.7 μm. Moreover, we present a quantitative numerical model predicting the imaging capabilities of QIUP for a wide range of parameters. Finally, by imaging mouse heart tissue at the mid-IR to reveal morphological features on the cellular level, we further demonstrate the viability of this technique for the life sciences. These results offer new perspectives on the capabilities of QIUP for label-free widefield mid-IR microscopy, enabling real-world biomedical as well as industrial imaging applications.