arXiv:2106.06435 · Optics Express

Mid-infrared microscopy via position correlations of undetected photons

Inna Kviatkovsky, Helen M. Chrzanowski, Sven Ramelow

Published Dec 13, 2021• 40 citations
arXivHTMLPDF

Abstract

Quantum imaging with undetected photons (QIUP) has recently emerged as a new powerful imaging tool. Exploiting the spatial entanglement of photon pairs, it allows decoupling of the sensing and detection wavelengths, facilitating imaging in otherwise challenging spectral regions by leveraging mature silicon-based detection technology. All existing implementations of QIUP have so far utilised the momentum correlations within the biphoton states produced by spontaneous parametric downconversion. Here, for the first time, we implement and examine theoretically and numerically the complementary scenario - utilising the tight position correlations formed within photon pairs at birth. This image plane arrangement facilitates high resolution imaging with comparative experimental ease, and we experimentally show resolutions below 10 μm at a sensing wavelength of 3.7 μm. Moreover, we present a quantitative numerical model predicting the imaging capabilities of QIUP for a wide range of parameters. Finally, by imaging mouse heart tissue at the mid-IR to reveal morphological features on the cellular level, we further demonstrate the viability of this technique for the life sciences. These results offer new perspectives on the capabilities of QIUP for label-free widefield mid-IR microscopy, enabling real-world biomedical as well as industrial imaging applications.

DOI
10.1364/oe.440534

Related papers

Microscopy with undetected photons in the mid-infrared

Inna Kviatkovsky, Helen M. Chrzanowski, Ellen G. Avery +2 more

Owing to its capacity for unique (bio)-chemical specificity, microscopy with mid-infrared (IR) illumination holds tremendous promise for a wide range of biomedical and industrial applications. The primary limitation, however, remains detection, with current mid-IR detection technology often marrying inferior technical capabilities with prohibitive costs. Here, we experimentally show how nonlinear interferometry with entangled light can provide a powerful tool for mid-IR microscopy while only requiring near-IR detection with a silicon-based camera. In this proof-of-principle implementation, we demonstrate widefield imaging over a broad wavelength range covering 3.4 to 4.3 μm and demonstrate a spatial resolution of 35 μm for images containing 650 resolved elements. Moreover, we demonstrate that our technique is suitable for acquiring microscopic images of biological tissue samples in the mid-IR. These results form a fresh perspective for potential relevance of quantum imaging techniques in the life sciences.

arXiv:2002.05960•Science Advances•Oct 16, 2020•213 citations

Resolution limit in quantum imaging with undetected photons using position correlations

Balakrishnan Viswanathan, Gabriela Barreto Lemos, Mayukh Lahiri

Quantum imaging with undetected photons (QIUP) is a unique method of image acquisition where the photons illuminating the object are not detected. This method relies on quantum interference and spatial correlations between the twin photons to form an image. Here we present a detailed study of the resolution limits of position correlation enabled QIUP. We establish a quantitative relation between the spatial resolution and the twin-photon position correlation. Furthermore, we also quantitatively establish the roles that the wavelength of the undetected illumination field and the wavelength of the detected field play in the resolution. Like ghost imaging and unlike conventional imaging, the resolution limit imposed by the spatial correlation between the twin photons in QIUP cannot be further improved by conventional optical techniques.

arXiv:2106.11358•Optics Express•Oct 7, 2021•31 citations

Wide-field mid- to long-wave infrared imaging with undetected photons

Vladimir Kornienko, Nathan Gemmell, Caiyi Liu +3 more

Quantum imaging with undetected photons (QIUP) allows an object to be probed at mid-infrared frequencies by only measuring interference in the visible range, thus leveraging silicon camera technology. We show that non-collinear phase-matching in a silver thiogallate (AgGaS$_2$) crystal enables wide-field QIUP in the wavelength range of 6-10 $μ$m (1670-1000 cm$^{-1}$). A combination of coherent detection and infrared photons being ``undetected'' enables imaging at ${\sim}$100 times better than the background-limited infrared photodetection (BLIP) limit. At 8 $μ$m, our images have over 8000 $\pm$ 100 resolvable elements with a 297 $\pm$ 5 $μ$m resolution, and 10 s acquisition time. Our results pave the way to fast, background-noise-free, room-temperature, spectrally-selective mid-infrared imaging.

quant-pharXiv:2608.20015•Aug 21, 2026•0 citations

Position correlation enabled quantum imaging with undetected photons

Balakrishnan Viswanathan, Gabriela Barreto Lemos, Mayukh Lahiri

Quantum imaging with undetected photons (QIUP) is a unique imaging technique that does not require the detection of the light used for illuminating the object. This technique requires a correlated pair of photons. In the existing implementations of QIUP, the imaging is enabled by the momentum correlation between the twin photons. We investigate the complementary scenario in which the imaging is instead enabled by the position correlation between the two photons. We present a general theory and show that the properties of the images obtained in these two cases are significantly distinct.

arXiv:2101.02761•Optics Letters•Jun 14, 2021•29 citations

Quantum metrology with undetected mid-infrared photons for applied non-destructive testing

Paul Gattinger, Andreas W. Schell, Maja Buchegger +2 more

Metrology with undetected photons is an emerging technique that leverages quantum effects and photon correlations (entanglement) to retrieve valuable information in a target spectral range (e.g., mid-infrared, mid-IR) using measurements in an easily accessible domain (e.g., visible, near-IR). The underlying quantum process of spontaneous parametric down-conversion (SPDC) is utilized to generate non-degenerate correlated signal and idler photons to serve as detection and probing photons, respectively. Sensing with undetected photons enables important advantages, such as ultra-low probe powers, room-temperature operation, and shot-noise-limited detection. In this contribution, we apply a quantum nonlinear interferometer based on an SPDC source to perform applied mid-IR spectroscopy, mid-IR microscopy, and mid-IR optical coherence tomography (OCT) as among the most promising techniques for quantum-based routine non-destructive testing. Moreover, we characterize the system, benchmark it against classical systems, and provide a prospective outlook for this new technology.

quant-pharXiv:2607.12653•e+i Elektrotechnik und Informationstechnik•Jul 15, 2026•0 citations

Quantum imaging with undetected photons

Filip Krajinić, J.R. Leon-Tores, M. Kumar +3 more

We present principles of quantum imaging with undetected photons (QIUP) and show modifications we made to the nonlinear interferometer for QUIP in order to use off-axes holography for faster image reconstruction. We present images made by off-axes quantum holography (OAQH) and discuss image capabilities of the system. In this work we use a pair of quantum correlated photons, generated by spontaneous parametric down-conversion in a non-linear crystal; one photon form a pair interacts with object, and another is detected. In our system both photons are in near infra-red, but by slight modifications they will be in different spectral regions, interacting photons in mid infra-red, detected photons in visible or near infra-ed. This opens very useful applications of QIUP for imaging and sensing in MIR.

International Conference on Transparent Optical Networks•Jul 14, 2024•1 citation
Quantum imaging with undetected photons (QIUP) has recently emerged as a new powerful imaging tool. Exploiting the spatial entanglement of photon pairs, it allows decoupling of the sensing and detection wavelengths, facilitating imaging in otherwise challenging spectral regions by leveraging mature silicon-based detection technology. All existing implementations of QIUP have so far utilised the momentum correlations within the biphoton states produced by spontaneous parametric downconversion. Here, for the first time, we implement and examine theoretically and numerically the complementary scenario - utilising the tight position correlations formed within photon pairs at birth. This image plane arrangement facilitates high resolution imaging with comparative experimental ease, and we experimentally show resolutions below 10 μm at a sensing wavelength of 3.7 μm. Moreover, we present a quantitative numerical model predicting the imaging capabilities of QIUP for a wide range of parameters. Finally, by imaging mouse heart tissue at the mid-IR to reveal morphological features on the cellular level, we further demonstrate the viability of this technique for the life sciences. These results offer new perspectives on the capabilities of QIUP for label-free widefield mid-IR microscopy, enabling real-world biomedical as well as industrial imaging applications.
Owing to its capacity for unique (bio)-chemical specificity, microscopy with mid-infrared (IR) illumination holds tremendous promise for a wide range of biomedical and industrial applications. The primary limitation, however, remains detection, with current mid-IR detection technology often marrying inferior technical capabilities with prohibitive costs. Here, we experimentally show how nonlinear interferometry with entangled light can provide a powerful tool for mid-IR microscopy while only requiring near-IR detection with a silicon-based camera. In this proof-of-principle implementation, we demonstrate widefield imaging over a broad wavelength range covering 3.4 to 4.3 μm and demonstrate a spatial resolution of 35 μm for images containing 650 resolved elements. Moreover, we demonstrate that our technique is suitable for acquiring microscopic images of biological tissue samples in the mid-IR. These results form a fresh perspective for potential relevance of quantum imaging techniques in the life sciences.
Quantum imaging with undetected photons (QIUP) is a unique method of image acquisition where the photons illuminating the object are not detected. This method relies on quantum interference and spatial correlations between the twin photons to form an image. Here we present a detailed study of the resolution limits of position correlation enabled QIUP. We establish a quantitative relation between the spatial resolution and the twin-photon position correlation. Furthermore, we also quantitatively establish the roles that the wavelength of the undetected illumination field and the wavelength of the detected field play in the resolution. Like ghost imaging and unlike conventional imaging, the resolution limit imposed by the spatial correlation between the twin photons in QIUP cannot be further improved by conventional optical techniques.
Quantum imaging with undetected photons (QIUP) allows an object to be probed at mid-infrared frequencies by only measuring interference in the visible range, thus leveraging silicon camera technology. We show that non-collinear phase-matching in a silver thiogallate (AgGaS2_22​) crystal enables wide-field QIUP in the wavelength range of 6-10 μμμm (1670-1000 cm−1^{-1}−1). A combination of coherent detection and infrared photons being ``undetected'' enables imaging at ${\sim}$100 times better than the background-limited infrared photodetection (BLIP) limit. At 8 μμμm, our images have over 8000 ±\pm± 100 resolvable elements with a 297 ±\pm± 5 μμμm resolution, and 10 s acquisition time. Our results pave the way to fast, background-noise-free, room-temperature, spectrally-selective mid-infrared imaging.
Quantum imaging with undetected photons (QIUP) is a unique imaging technique that does not require the detection of the light used for illuminating the object. This technique requires a correlated pair of photons. In the existing implementations of QIUP, the imaging is enabled by the momentum correlation between the twin photons. We investigate the complementary scenario in which the imaging is instead enabled by the position correlation between the two photons. We present a general theory and show that the properties of the images obtained in these two cases are significantly distinct.
Metrology with undetected photons is an emerging technique that leverages quantum effects and photon correlations (entanglement) to retrieve valuable information in a target spectral range (e.g., mid-infrared, mid-IR) using measurements in an easily accessible domain (e.g., visible, near-IR). The underlying quantum process of spontaneous parametric down-conversion (SPDC) is utilized to generate non-degenerate correlated signal and idler photons to serve as detection and probing photons, respectively. Sensing with undetected photons enables important advantages, such as ultra-low probe powers, room-temperature operation, and shot-noise-limited detection. In this contribution, we apply a quantum nonlinear interferometer based on an SPDC source to perform applied mid-IR spectroscopy, mid-IR microscopy, and mid-IR optical coherence tomography (OCT) as among the most promising techniques for quantum-based routine non-destructive testing. Moreover, we characterize the system, benchmark it against classical systems, and provide a prospective outlook for this new technology.
We present principles of quantum imaging with undetected photons (QIUP) and show modifications we made to the nonlinear interferometer for QUIP in order to use off-axes holography for faster image reconstruction. We present images made by off-axes quantum holography (OAQH) and discuss image capabilities of the system. In this work we use a pair of quantum correlated photons, generated by spontaneous parametric down-conversion in a non-linear crystal; one photon form a pair interacts with object, and another is detected. In our system both photons are in near infra-red, but by slight modifications they will be in different spectral regions, interacting photons in mid infra-red, detected photons in visible or near infra-ed. This opens very useful applications of QIUP for imaging and sensing in MIR.