Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2002.05960 · Science Advances

Microscopy with undetected photons in the mid-infrared

Inna Kviatkovsky, Helen M. Chrzanowski, Ellen G. Avery, Hendrik Bartolomaeus, Sven Ramelow

Published Oct 16, 2020• 213 citations
arXivHTMLPDF

Abstract

Owing to its capacity for unique (bio)-chemical specificity, microscopy with mid-infrared (IR) illumination holds tremendous promise for a wide range of biomedical and industrial applications. The primary limitation, however, remains detection, with current mid-IR detection technology often marrying inferior technical capabilities with prohibitive costs. Here, we experimentally show how nonlinear interferometry with entangled light can provide a powerful tool for mid-IR microscopy while only requiring near-IR detection with a silicon-based camera. In this proof-of-principle implementation, we demonstrate widefield imaging over a broad wavelength range covering 3.4 to 4.3 μm and demonstrate a spatial resolution of 35 μm for images containing 650 resolved elements. Moreover, we demonstrate that our technique is suitable for acquiring microscopic images of biological tissue samples in the mid-IR. These results form a fresh perspective for potential relevance of quantum imaging techniques in the life sciences.

DOI
10.1126/sciadv.abd0264

Related papers

Mid-infrared microscopy via position correlations of undetected photons

Inna Kviatkovsky, Helen M. Chrzanowski, Sven Ramelow

Quantum imaging with undetected photons (QIUP) has recently emerged as a new powerful imaging tool. Exploiting the spatial entanglement of photon pairs, it allows decoupling of the sensing and detection wavelengths, facilitating imaging in otherwise challenging spectral regions by leveraging mature silicon-based detection technology. All existing implementations of QIUP have so far utilised the momentum correlations within the biphoton states produced by spontaneous parametric downconversion. Here, for the first time, we implement and examine theoretically and numerically the complementary scenario - utilising the tight position correlations formed within photon pairs at birth. This image plane arrangement facilitates high resolution imaging with comparative experimental ease, and we experimentally show resolutions below 10 μm at a sensing wavelength of 3.7 μm. Moreover, we present a quantitative numerical model predicting the imaging capabilities of QIUP for a wide range of parameters. Finally, by imaging mouse heart tissue at the mid-IR to reveal morphological features on the cellular level, we further demonstrate the viability of this technique for the life sciences. These results offer new perspectives on the capabilities of QIUP for label-free widefield mid-IR microscopy, enabling real-world biomedical as well as industrial imaging applications.

arXiv:2106.06435•Optics Express•Dec 13, 2021•40 citations

Mid-IR hyperspectral imaging with undetected photons

Marlon Placke, Chiara Lindner, Felix Mann +5 more

Sensing with undetected photons has become a vibrant, application-driven research domain with a special focus on the mid-infrared (mid-IR) wavelength region. Since the mid-IR contains spectral bands with highly specific and strong molecular absorbance signatures, often referred to as fingerprints, a multitude of different samples and their compositions can be detected and quantified spectroscopically. Enhancing this spectroscopic method with imaging capabilities leads to a powerful technique for environmental monitoring and biomedical applications that enables automated diagnostics while omitting time-consuming and non-reversible labeling steps. To evade the shortcomings of state-of-the-art instruments for mid-IR hyperspectral microscopy—namely cost, complexity, power consumption, and performance, which stem from technological challenges in mid-IR detection and light sources—we construct a proof-of-concept nonlinear interferometer in a wide-field imaging arrangement. This nominally narrowband imaging technique is then expanded to acquire broadband spectral information through capturing images for varying interferometer displacement and applying a pixelwise Fourier-transform of the resulting interferograms, yielding high-resolution infrared spectra for each camera pixel. For the broadband range of 2300−3100cm −1 , covering the important CH-stretch band, we perform hyperspectral imaging that simultaneously resolves 3500 spatial modes, each with a spectral resolution of 10cm −1 , leveraging in total around 10 5 spatio-spectrally entangled photon modes. Our image acquisition uses a commercial sCMOS camera, while a medium-power and compact continuous-wave pump laser is the only necessary light source. For a moderate speed of 360 voxel/s, we obtain a predominantly shot-noise-influenced signal-to-noise ratio (SNR) of 50. We further demonstrate the practicality of our novel hyperspectral imaging technique for microplastics detection and bio-imaging tasks and outline engineering solutions to increase its speed by several orders of magnitude. This shows that our quantum imaging technique is highly promising for applications requiring compact, cost-effective label-free analyses.

Optica•Jan 9, 2026•5 citations

Mid-IR hyperspectral imaging with undetected photons

Marlon Placke, Chiara Lindner, Felix Mann +4 more

By combining a nonlinear interferometer in imaging-mode with Fourier-transform spectroscopy, we realize broadband mid-infrared hyperspectral acquisition with undetected photons. We demonstrate the novel imaging technique on polymer and bio-tissue samples using only near-infrared silicon-based cameras.

Quantum 2.0 Conference and Exhibition•Jan 1, 2024•0 citations

Mid-Infrared Quantum Scanning Microscopy with Visible Light

Josué Ricardo León-Torres, Jorge Fuenzalida, Marta Gilaberte Basset +2 more

Laser scanning microscopy (LSM) is known to be the workhorse for modern life-science, it allows to get new insights into a variety of biological processes. LSM together with illumination in the mid infrared region (Mid-IR) permits to map the chemical composition of samples to a space frame. However, low-light observations in the Mid-IR spectrum are still challenging and a limiting factor for a faster development. A label-free quantum scanning imaging system is presented here, capable of performing the detection in the visible regime, while the illumination is carried out in the Mid-IR region. Our quantum imaging with undetected light implementation aims to retrieve amplitude and phase images of biological samples containing a variety of functional groups that are present in the Mid-IR region

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•1 citation

Frequency-domain optical coherence tomography with undetected mid-infrared photons

Aron Vanselow, Paul Kaufmann, Ivan Zorin +3 more

Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.

arXiv:2006.07400•Optica•Oct 28, 2020•109 citations

Quantum metrology with undetected mid-infrared photons for applied non-destructive testing

Paul Gattinger, Andreas W. Schell, Maja Buchegger +2 more

Metrology with undetected photons is an emerging technique that leverages quantum effects and photon correlations (entanglement) to retrieve valuable information in a target spectral range (e.g., mid-infrared, mid-IR) using measurements in an easily accessible domain (e.g., visible, near-IR). The underlying quantum process of spontaneous parametric down-conversion (SPDC) is utilized to generate non-degenerate correlated signal and idler photons to serve as detection and probing photons, respectively. Sensing with undetected photons enables important advantages, such as ultra-low probe powers, room-temperature operation, and shot-noise-limited detection. In this contribution, we apply a quantum nonlinear interferometer based on an SPDC source to perform applied mid-IR spectroscopy, mid-IR microscopy, and mid-IR optical coherence tomography (OCT) as among the most promising techniques for quantum-based routine non-destructive testing. Moreover, we characterize the system, benchmark it against classical systems, and provide a prospective outlook for this new technology.

quant-pharXiv:2607.12653•e+i Elektrotechnik und Informationstechnik•Jul 15, 2026•0 citations
Owing to its capacity for unique (bio)-chemical specificity, microscopy with mid-infrared (IR) illumination holds tremendous promise for a wide range of biomedical and industrial applications. The primary limitation, however, remains detection, with current mid-IR detection technology often marrying inferior technical capabilities with prohibitive costs. Here, we experimentally show how nonlinear interferometry with entangled light can provide a powerful tool for mid-IR microscopy while only requiring near-IR detection with a silicon-based camera. In this proof-of-principle implementation, we demonstrate widefield imaging over a broad wavelength range covering 3.4 to 4.3 μm and demonstrate a spatial resolution of 35 μm for images containing 650 resolved elements. Moreover, we demonstrate that our technique is suitable for acquiring microscopic images of biological tissue samples in the mid-IR. These results form a fresh perspective for potential relevance of quantum imaging techniques in the life sciences.
Quantum imaging with undetected photons (QIUP) has recently emerged as a new powerful imaging tool. Exploiting the spatial entanglement of photon pairs, it allows decoupling of the sensing and detection wavelengths, facilitating imaging in otherwise challenging spectral regions by leveraging mature silicon-based detection technology. All existing implementations of QIUP have so far utilised the momentum correlations within the biphoton states produced by spontaneous parametric downconversion. Here, for the first time, we implement and examine theoretically and numerically the complementary scenario - utilising the tight position correlations formed within photon pairs at birth. This image plane arrangement facilitates high resolution imaging with comparative experimental ease, and we experimentally show resolutions below 10 μm at a sensing wavelength of 3.7 μm. Moreover, we present a quantitative numerical model predicting the imaging capabilities of QIUP for a wide range of parameters. Finally, by imaging mouse heart tissue at the mid-IR to reveal morphological features on the cellular level, we further demonstrate the viability of this technique for the life sciences. These results offer new perspectives on the capabilities of QIUP for label-free widefield mid-IR microscopy, enabling real-world biomedical as well as industrial imaging applications.
Sensing with undetected photons has become a vibrant, application-driven research domain with a special focus on the mid-infrared (mid-IR) wavelength region. Since the mid-IR contains spectral bands with highly specific and strong molecular absorbance signatures, often referred to as fingerprints, a multitude of different samples and their compositions can be detected and quantified spectroscopically. Enhancing this spectroscopic method with imaging capabilities leads to a powerful technique for environmental monitoring and biomedical applications that enables automated diagnostics while omitting time-consuming and non-reversible labeling steps. To evade the shortcomings of state-of-the-art instruments for mid-IR hyperspectral microscopy—namely cost, complexity, power consumption, and performance, which stem from technological challenges in mid-IR detection and light sources—we construct a proof-of-concept nonlinear interferometer in a wide-field imaging arrangement. This nominally narrowband imaging technique is then expanded to acquire broadband spectral information through capturing images for varying interferometer displacement and applying a pixelwise Fourier-transform of the resulting interferograms, yielding high-resolution infrared spectra for each camera pixel. For the broadband range of 2300−3100cm −1 , covering the important CH-stretch band, we perform hyperspectral imaging that simultaneously resolves 3500 spatial modes, each with a spectral resolution of 10cm −1 , leveraging in total around 10 5 spatio-spectrally entangled photon modes. Our image acquisition uses a commercial sCMOS camera, while a medium-power and compact continuous-wave pump laser is the only necessary light source. For a moderate speed of 360 voxel/s, we obtain a predominantly shot-noise-influenced signal-to-noise ratio (SNR) of 50. We further demonstrate the practicality of our novel hyperspectral imaging technique for microplastics detection and bio-imaging tasks and outline engineering solutions to increase its speed by several orders of magnitude. This shows that our quantum imaging technique is highly promising for applications requiring compact, cost-effective label-free analyses.
Laser scanning microscopy (LSM) is known to be the workhorse for modern life-science, it allows to get new insights into a variety of biological processes. LSM together with illumination in the mid infrared region (Mid-IR) permits to map the chemical composition of samples to a space frame. However, low-light observations in the Mid-IR spectrum are still challenging and a limiting factor for a faster development. A label-free quantum scanning imaging system is presented here, capable of performing the detection in the visible regime, while the illumination is carried out in the Mid-IR region. Our quantum imaging with undetected light implementation aims to retrieve amplitude and phase images of biological samples containing a variety of functional groups that are present in the Mid-IR region
Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.
Metrology with undetected photons is an emerging technique that leverages quantum effects and photon correlations (entanglement) to retrieve valuable information in a target spectral range (e.g., mid-infrared, mid-IR) using measurements in an easily accessible domain (e.g., visible, near-IR). The underlying quantum process of spontaneous parametric down-conversion (SPDC) is utilized to generate non-degenerate correlated signal and idler photons to serve as detection and probing photons, respectively. Sensing with undetected photons enables important advantages, such as ultra-low probe powers, room-temperature operation, and shot-noise-limited detection. In this contribution, we apply a quantum nonlinear interferometer based on an SPDC source to perform applied mid-IR spectroscopy, mid-IR microscopy, and mid-IR optical coherence tomography (OCT) as among the most promising techniques for quantum-based routine non-destructive testing. Moreover, we characterize the system, benchmark it against classical systems, and provide a prospective outlook for this new technology.