arXiv:2304.04378 · International Conference on Low Temperature Physics (LT)

Josephson Parametric Amplifier in Axion Experiments

Jinmyeong Kim, Boris I. Ivanov, Çağlar Kutlu, Seongtae Park, Arjan F. van Loo, Yasunobu Nakamura, Sergey V. Uchaikin, Seonjeong Oh, Violeta Gkika, Andrei N. Matlashov, Woohyun Chung, Yannis Kyriakos Semertzidis

Published May 22, 2023• 4 citations
arXivHTMLPDF

Abstract

The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem.Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature.We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta.In our measurements to characterize the JPA we have found the added noise to the system with a JPA as the first-stage amplifier to be lower than 110 mK at the frequencies from 0.938 GHz to 0.963 GHz.

DOI
10.7566/jpscp.38.011199

Related papers

Characterization of a flux-driven Josephson parametric amplifier with near quantum-limited added noise for axion search experiments

Çağlar Kutlu, Arjan F. van Loo, Sergey V. Uchaikin +7 more

Abstract The experimental non-observation of charge-parity (CP) symmetry violation in quantum chromodynamics is commonly referred to as the strong CP problem. The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors affecting the parameter scanning speed of these detectors is the noise added by the components in the signal detection chain. Since the first amplifier in the chain limits the minimum noise, low-noise amplification is of paramount importance. This paper reports on the operation of a flux-driven Josephson parametric amplifier (JPA) operating at around 2.3 GHz with added noise approaching the quantum limit. The JPA was employed as a first stage amplifier in an experimental setting similar to the ones used in haloscope axion detectors. By operating the JPA at a gain of 19 dB and cascading it with two cryogenic amplifiers operating at 4 K, noise temperatures as low as 120 mK were achieved for the whole signal detection chain.

arXiv:2101.08496•Superconductor Science and Technology•Mar 25, 2021•43 citations

Multi-JPA configuration to broaden amplification bandwidth for axion haloscope experiments

Boris I. Ivanov, Sergey V. Uchaikin, Jinmyeong Kim +7 more

Abstract Josephson parametric amplifiers (JPAs) are used in a wide range of applications, including quantum sensing and axion dark matter searches, due to their near-quantum-limited noise performance. In this article, we present a novel amplifier configuration that increases the frequency scanning range for axion search experiments by combining six narrow-band, flux-driven JPAs. The design consists of two subsets, each comprising three JPAs connected in parallel and coupled to one of two circulators. These subsets are arranged in series. A single pump tone is split and distributed across all JPAs. We effectively mitigated challenges associated with frequency tuning and cross-talk arising from JPA band overlap while maintaining low noise performance. To validate this configuration, we implemented a JPA system spanning 1.2–1.5 GHz as the first-stage amplifier in an RF chain, where the total noise was measured to be approximately twice the standard quantum limit.

Superconductor Science and Technology•Jan 19, 2026•0 citations

Parameter Optimization of Josephson Parametric Amplifiers Using a Heuristic Search Algorithm for Axion Haloscope Search

Young-Geun Kim, Junu Jeong, SungWoo Youn +5 more

The cavity haloscope is among the most widely adopted experimental platforms designed to detect dark matter axions with its principle relying on the conversion of axions into microwave photons in the presence of a strong magnetic field. The Josephson parametric amplifier (JPA), known for its quantum-limited noise characteristics, has been incorporated into the detection system to capture the weakly interacting axion signals. However, the performance of the JPA can be influenced by its environment, leading to the potential unreliability of a predefined parameter set obtained in a specific laboratory setting. Furthermore, conducting a broadband search requires the consecutive characterization of the amplifier across different tuning frequencies. To ensure more reliable measurements, we utilize the Nelder–Mead technique as a numerical search method to dynamically determine the optimal operating conditions. This heuristic search algorithm explores the multidimensional parameter space of the JPA, optimizing critical characteristics such as gain and noise temperature to maximize signal-to-noise ratios for a given experimental setup. Our study presents a comprehensive analysis of the properties of a flux-driven JPA to demonstrate the effectiveness of the algorithm. This approach contributes to ongoing efforts in axion dark matter research by offering an efficient method to enhance axion detection sensitivity through the optimized utilization of JPAs.

arXiv:2404.18345•Electronics•May 29, 2024•3 citations

Systematic Approach for Tuning Flux-driven Josephson Parametric Amplifiers for Stochastic Small Signals

Çağlar Kutlu, Saebyeok Ahn, Sergey V. Uchaikin +5 more

Many experiments operating at millikelvin temperatures with signal frequencies in the microwave regime are beginning to incorporate Josephson Parametric Amplifiers (JPA) as their first amplification stage.While there are implementations for a wideband frequency response with a minimal need for tuning, designs using resonant structures with small numbers of Josephson elements still achieve the best noise performance.In a typical measurement scheme involving a JPA, one needs to control the resonance frequency, pump frequency and pump power to achieve the desired amplification and noise properties.In this work, we propose a straightforward approach for operating JPAs with the help of a look-up table (LUT) and online fine-tuning.Using the proposed approach, we demonstrate the operation of a flux-driven JPA with 20 dB gain around 5.9 GHz, covering approximately 100 MHz with 20 kHz tuning steps.The proposed methodology was successfully used in the context of a haloscope axion experiment.

arXiv:2305.08866•International Conference on Low Temperature Physics (LT)•May 22, 2023•2 citations

Approaching the Quantum Limit in Axion Detection at IBS-CAPP and IBS-DMAG

Sergey V. Uchaikin, Boris I. Ivanov, Arjan F. van Loo +7 more

We present the development of two complementary amplifier architectures for axion haloscope experiments, based on two types of Josephson Parametric Amplifiers (JPAs).The first employs a multi-chip module of flux-driven JPAs in a parallel-series configuration, enabling near quantum-limited amplification over an extended tunable range of between 1.2 and 1.5 GHz.The second design features a lumped-element JPA, offering continuous tunability across a wide frequency range from 2.4 to 4 GHz.Both approaches demonstrate near-quantum-limited noise performance and are compatible with operation in cryogenic environments.These amplifiers significantly enhance the sensitivity and frequency coverage of axion search experiments, and also provide new opportunities for broadband quantum sensing applications.

•Nov 26, 2025•0 citations

Improving Amplification Bandwidth by Combining Josephson Parametric Amplifiers for Active Axion Search Experiments at IBS/CAPP

Sergey V. Uchaikin, Jinmyeong Kim, Boris I. Ivanov +8 more

Abstract IBS/CAPP in South Korea is home to multiple active axion search experiments using cavity haloscopes that operate within the frequency range of 1-6 GHz. The haloscopes convert axions to photons, resulting in an output power of about 10-24 to 10-22 W. To detect such a small signal amidst noise, quantum-limited noise amplifiers and ultra-low-temperature environment (∼10 mK) are required for all critical read-out components to minimize noise from all of active and passive lossy components. Additionally, operating at low dissipation levels is necessary to maintain the haloscope and amplifier at a temperature of 25-40 mK. Our primary objective is to achieve the highest possible scanning-frequency speed, which includes the time for maintenance and system calibration. For the CAPP-MAX flagship experiment, we achieved a record speed of 3 MHz/day for the DFSZ-level axion sensitivity during uninterrupting measurements. This paper presents the development and operation of low-noise amplifiers for five haloscope experiments targeting different frequency ranges and provides design, operational, and performance details of the amplifiers.

Journal of Low Temperature Physics•Jul 1, 2024•5 citations
The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem.Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature.We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta.In our measurements to characterize the JPA we have found the added noise to the system with a JPA as the first-stage amplifier to be lower than 110 mK at the frequencies from 0.938 GHz to 0.963 GHz.
Abstract The experimental non-observation of charge-parity (CP) symmetry violation in quantum chromodynamics is commonly referred to as the strong CP problem. The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors affecting the parameter scanning speed of these detectors is the noise added by the components in the signal detection chain. Since the first amplifier in the chain limits the minimum noise, low-noise amplification is of paramount importance. This paper reports on the operation of a flux-driven Josephson parametric amplifier (JPA) operating at around 2.3 GHz with added noise approaching the quantum limit. The JPA was employed as a first stage amplifier in an experimental setting similar to the ones used in haloscope axion detectors. By operating the JPA at a gain of 19 dB and cascading it with two cryogenic amplifiers operating at 4 K, noise temperatures as low as 120 mK were achieved for the whole signal detection chain.
Abstract Josephson parametric amplifiers (JPAs) are used in a wide range of applications, including quantum sensing and axion dark matter searches, due to their near-quantum-limited noise performance. In this article, we present a novel amplifier configuration that increases the frequency scanning range for axion search experiments by combining six narrow-band, flux-driven JPAs. The design consists of two subsets, each comprising three JPAs connected in parallel and coupled to one of two circulators. These subsets are arranged in series. A single pump tone is split and distributed across all JPAs. We effectively mitigated challenges associated with frequency tuning and cross-talk arising from JPA band overlap while maintaining low noise performance. To validate this configuration, we implemented a JPA system spanning 1.2–1.5 GHz as the first-stage amplifier in an RF chain, where the total noise was measured to be approximately twice the standard quantum limit.
The cavity haloscope is among the most widely adopted experimental platforms designed to detect dark matter axions with its principle relying on the conversion of axions into microwave photons in the presence of a strong magnetic field. The Josephson parametric amplifier (JPA), known for its quantum-limited noise characteristics, has been incorporated into the detection system to capture the weakly interacting axion signals. However, the performance of the JPA can be influenced by its environment, leading to the potential unreliability of a predefined parameter set obtained in a specific laboratory setting. Furthermore, conducting a broadband search requires the consecutive characterization of the amplifier across different tuning frequencies. To ensure more reliable measurements, we utilize the Nelder–Mead technique as a numerical search method to dynamically determine the optimal operating conditions. This heuristic search algorithm explores the multidimensional parameter space of the JPA, optimizing critical characteristics such as gain and noise temperature to maximize signal-to-noise ratios for a given experimental setup. Our study presents a comprehensive analysis of the properties of a flux-driven JPA to demonstrate the effectiveness of the algorithm. This approach contributes to ongoing efforts in axion dark matter research by offering an efficient method to enhance axion detection sensitivity through the optimized utilization of JPAs.
Many experiments operating at millikelvin temperatures with signal frequencies in the microwave regime are beginning to incorporate Josephson Parametric Amplifiers (JPA) as their first amplification stage.While there are implementations for a wideband frequency response with a minimal need for tuning, designs using resonant structures with small numbers of Josephson elements still achieve the best noise performance.In a typical measurement scheme involving a JPA, one needs to control the resonance frequency, pump frequency and pump power to achieve the desired amplification and noise properties.In this work, we propose a straightforward approach for operating JPAs with the help of a look-up table (LUT) and online fine-tuning.Using the proposed approach, we demonstrate the operation of a flux-driven JPA with 20 dB gain around 5.9 GHz, covering approximately 100 MHz with 20 kHz tuning steps.The proposed methodology was successfully used in the context of a haloscope axion experiment.
We present the development of two complementary amplifier architectures for axion haloscope experiments, based on two types of Josephson Parametric Amplifiers (JPAs).The first employs a multi-chip module of flux-driven JPAs in a parallel-series configuration, enabling near quantum-limited amplification over an extended tunable range of between 1.2 and 1.5 GHz.The second design features a lumped-element JPA, offering continuous tunability across a wide frequency range from 2.4 to 4 GHz.Both approaches demonstrate near-quantum-limited noise performance and are compatible with operation in cryogenic environments.These amplifiers significantly enhance the sensitivity and frequency coverage of axion search experiments, and also provide new opportunities for broadband quantum sensing applications.
Abstract IBS/CAPP in South Korea is home to multiple active axion search experiments using cavity haloscopes that operate within the frequency range of 1-6 GHz. The haloscopes convert axions to photons, resulting in an output power of about 10-24 to 10-22 W. To detect such a small signal amidst noise, quantum-limited noise amplifiers and ultra-low-temperature environment (∼10 mK) are required for all critical read-out components to minimize noise from all of active and passive lossy components. Additionally, operating at low dissipation levels is necessary to maintain the haloscope and amplifier at a temperature of 25-40 mK. Our primary objective is to achieve the highest possible scanning-frequency speed, which includes the time for maintenance and system calibration. For the CAPP-MAX flagship experiment, we achieved a record speed of 3 MHz/day for the DFSZ-level axion sensitivity during uninterrupting measurements. This paper presents the development and operation of low-noise amplifiers for five haloscope experiments targeting different frequency ranges and provides design, operational, and performance details of the amplifiers.