Journal of Low Temperature Physics

Improving Amplification Bandwidth by Combining Josephson Parametric Amplifiers for Active Axion Search Experiments at IBS/CAPP

Sergey V. Uchaikin, Jinmyeong Kim, Boris I. Ivanov, Arjan F. van Loo, Yasunobu Nakamura, Saebyeok Ahn, Seonjeong Oh, Seongtae Park, Andrei N. Matlashov, Woohyun Chung, Yannis Kyriakos Semertzidis

Published Jul 1, 2024• 5 citations
Publisher

Abstract

Abstract IBS/CAPP in South Korea is home to multiple active axion search experiments using cavity haloscopes that operate within the frequency range of 1-6 GHz. The haloscopes convert axions to photons, resulting in an output power of about 10-24 to 10-22 W. To detect such a small signal amidst noise, quantum-limited noise amplifiers and ultra-low-temperature environment (∼10 mK) are required for all critical read-out components to minimize noise from all of active and passive lossy components. Additionally, operating at low dissipation levels is necessary to maintain the haloscope and amplifier at a temperature of 25-40 mK. Our primary objective is to achieve the highest possible scanning-frequency speed, which includes the time for maintenance and system calibration. For the CAPP-MAX flagship experiment, we achieved a record speed of 3 MHz/day for the DFSZ-level axion sensitivity during uninterrupting measurements. This paper presents the development and operation of low-noise amplifiers for five haloscope experiments targeting different frequency ranges and provides design, operational, and performance details of the amplifiers.

DOI
10.1007/s10909-024-03090-5

Related papers

Four-channel System for Characterization of Josephson Parametric Amplifiers

Boris I. Ivanov, Jinmyeong Kim, Çağlar Kutlu +8 more

The axion search experiments based on haloscopes at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in South Korea are performed in the frequency range from 1 GHz to 6 GHz.In order to perform the experiments in a strong magnetic field of 12 T and a large-volume cavity of close to 40 liters, we use He wet dilution refrigerators with immersed superconducting magnets.The measurements require continuous operation for months without interruptions for microwave component replacements.This is achieved by using different cryogenic engineering approaches including microwave RF-switching.The critical components, defining the scanning rate and the sensitivity of the setup, are the Josephson parametric amplifiers (JPA) and cryogenic low noise amplifiers (cLNA) based on high-electron-mobility-transistor (HEMT) technology.It is desirable for both devices to have a wide frequency range and low noise close to the quantum limit for the JPA.In this paper, we show a recent design of a 4-channel measurement setup for JPA and HEMT measurements.The setup is based on a 4-channel wideband noise source (NS) and is used for both JPA and HEMT gain and noise measurements.The setup is placed at 20 mK inside the dry dilution refrigerator.The NS is thermally decoupled from the environment using plastic spacers, superconducting wires and superconducting coaxial cables.We show the gain and noise temperature curves measured for 4 HEMT amplifiers and 2 JPAs in one cool-down.

arXiv:2304.13367•International Conference on Low Temperature Physics (LT)•May 22, 2023•4 citations

Approaching the Quantum Limit in Axion Detection at IBS-CAPP and IBS-DMAG

Sergey V. Uchaikin, Boris I. Ivanov, Arjan F. van Loo +7 more

We present the development of two complementary amplifier architectures for axion haloscope experiments, based on two types of Josephson Parametric Amplifiers (JPAs).The first employs a multi-chip module of flux-driven JPAs in a parallel-series configuration, enabling near quantum-limited amplification over an extended tunable range of between 1.2 and 1.5 GHz.The second design features a lumped-element JPA, offering continuous tunability across a wide frequency range from 2.4 to 4 GHz.Both approaches demonstrate near-quantum-limited noise performance and are compatible with operation in cryogenic environments.These amplifiers significantly enhance the sensitivity and frequency coverage of axion search experiments, and also provide new opportunities for broadband quantum sensing applications.

•Nov 26, 2025•0 citations

Josephson parametric amplifier based quantum noise limited amplifier development for axion search experiments in CAPP

Sergey V. Uchaikin, Jinmyeong Kim, Çağlar Kutlu +8 more

This paper provides a comprehensive overview of the development of flux-driven Josephson Parametric Amplifiers (JPAs) as Quantum Noise Limited Amplifier for axion search experiments conducted at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science. It focuses on the characterization, and optimization of JPAs, which are crucial for achieving the highest sensitivity in axion particle detection. We discuss various characterization techniques, methods for improving bandwidth, and the attainment of ultra-low noise temperatures. JPAs have emerged as indispensable tools in CAPP’s axion search endeavors, playing a significant role in advancing our understanding of fundamental physics and unraveling the mysteries of the Universe.

arXiv:2406.07899•Frontiers in Physics•Jul 23, 2024•9 citations

Wideband Amplification for IBS-CAPP's Axion Search Experiments

Jinmyeong Kim, Minsu Ko, Sergey V. Uchaikin +7 more

Abstract We present a novel amplifier configuration that combines six relatively narrow-band flux-drive Josephson Parametric Amplifiers (JPAs) to extend the bandwidth for the axion search experiments. We have addressed challenges related to the tuning and cross-talk resulting from JPA band overlap while maintaining low noise levels. Our measurements demonstrate that the added noise by an RF chain, with the JPA acting as the primary stage amplifier, remains between 75 and 175 mK from 1.19 to 1.33 GHz and from 1.36 to 1.5 GHz.

•Nov 7, 2023•1 citation

Multi-JPA configuration to broaden amplification bandwidth for axion haloscope experiments

Boris I. Ivanov, Sergey V. Uchaikin, Jinmyeong Kim +7 more

Abstract Josephson parametric amplifiers (JPAs) are used in a wide range of applications, including quantum sensing and axion dark matter searches, due to their near-quantum-limited noise performance. In this article, we present a novel amplifier configuration that increases the frequency scanning range for axion search experiments by combining six narrow-band, flux-driven JPAs. The design consists of two subsets, each comprising three JPAs connected in parallel and coupled to one of two circulators. These subsets are arranged in series. A single pump tone is split and distributed across all JPAs. We effectively mitigated challenges associated with frequency tuning and cross-talk arising from JPA band overlap while maintaining low noise performance. To validate this configuration, we implemented a JPA system spanning 1.2–1.5 GHz as the first-stage amplifier in an RF chain, where the total noise was measured to be approximately twice the standard quantum limit.

Superconductor Science and Technology•Jan 19, 2026•0 citations

Development of SQUID Amplifiers for Axion Search Experiments

Sergey V. Uchaikin, Andrei N. Matlashov, Doyu Lee +11 more

We report results of our development of two types of microwave amplifiers based on Superconducting quantum interference devices (SQUIDs) for CAPP (Center for Axion and Precision Physics Research) axion search experiments. The first amplifier, Microstrip SQUID Amplifier (MSA) has a wide bandwidth. Power dissipation in resistive shunts results in a device overheating and limits the MSA performances. A thermal models of shunt cooling processes is developed and recommendations for a future design is provided. The second amplifier, Josephson Parametric Amplifier (JPA), at limited bandwidth showed a low noise near the standard quantum limit (SQL) of 196 mK. Implementation of a JPA in CULTASK (CAPP's Ultra-Low Temperature Axion Search in Korea) experiment is planned in the end of 2019.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2019•3 citations
Abstract IBS/CAPP in South Korea is home to multiple active axion search experiments using cavity haloscopes that operate within the frequency range of 1-6 GHz. The haloscopes convert axions to photons, resulting in an output power of about 10-24 to 10-22 W. To detect such a small signal amidst noise, quantum-limited noise amplifiers and ultra-low-temperature environment (∼10 mK) are required for all critical read-out components to minimize noise from all of active and passive lossy components. Additionally, operating at low dissipation levels is necessary to maintain the haloscope and amplifier at a temperature of 25-40 mK. Our primary objective is to achieve the highest possible scanning-frequency speed, which includes the time for maintenance and system calibration. For the CAPP-MAX flagship experiment, we achieved a record speed of 3 MHz/day for the DFSZ-level axion sensitivity during uninterrupting measurements. This paper presents the development and operation of low-noise amplifiers for five haloscope experiments targeting different frequency ranges and provides design, operational, and performance details of the amplifiers.
The axion search experiments based on haloscopes at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in South Korea are performed in the frequency range from 1 GHz to 6 GHz.In order to perform the experiments in a strong magnetic field of 12 T and a large-volume cavity of close to 40 liters, we use He wet dilution refrigerators with immersed superconducting magnets.The measurements require continuous operation for months without interruptions for microwave component replacements.This is achieved by using different cryogenic engineering approaches including microwave RF-switching.The critical components, defining the scanning rate and the sensitivity of the setup, are the Josephson parametric amplifiers (JPA) and cryogenic low noise amplifiers (cLNA) based on high-electron-mobility-transistor (HEMT) technology.It is desirable for both devices to have a wide frequency range and low noise close to the quantum limit for the JPA.In this paper, we show a recent design of a 4-channel measurement setup for JPA and HEMT measurements.The setup is based on a 4-channel wideband noise source (NS) and is used for both JPA and HEMT gain and noise measurements.The setup is placed at 20 mK inside the dry dilution refrigerator.The NS is thermally decoupled from the environment using plastic spacers, superconducting wires and superconducting coaxial cables.We show the gain and noise temperature curves measured for 4 HEMT amplifiers and 2 JPAs in one cool-down.
We present the development of two complementary amplifier architectures for axion haloscope experiments, based on two types of Josephson Parametric Amplifiers (JPAs).The first employs a multi-chip module of flux-driven JPAs in a parallel-series configuration, enabling near quantum-limited amplification over an extended tunable range of between 1.2 and 1.5 GHz.The second design features a lumped-element JPA, offering continuous tunability across a wide frequency range from 2.4 to 4 GHz.Both approaches demonstrate near-quantum-limited noise performance and are compatible with operation in cryogenic environments.These amplifiers significantly enhance the sensitivity and frequency coverage of axion search experiments, and also provide new opportunities for broadband quantum sensing applications.
This paper provides a comprehensive overview of the development of flux-driven Josephson Parametric Amplifiers (JPAs) as Quantum Noise Limited Amplifier for axion search experiments conducted at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science. It focuses on the characterization, and optimization of JPAs, which are crucial for achieving the highest sensitivity in axion particle detection. We discuss various characterization techniques, methods for improving bandwidth, and the attainment of ultra-low noise temperatures. JPAs have emerged as indispensable tools in CAPP’s axion search endeavors, playing a significant role in advancing our understanding of fundamental physics and unraveling the mysteries of the Universe.
Abstract We present a novel amplifier configuration that combines six relatively narrow-band flux-drive Josephson Parametric Amplifiers (JPAs) to extend the bandwidth for the axion search experiments. We have addressed challenges related to the tuning and cross-talk resulting from JPA band overlap while maintaining low noise levels. Our measurements demonstrate that the added noise by an RF chain, with the JPA acting as the primary stage amplifier, remains between 75 and 175 mK from 1.19 to 1.33 GHz and from 1.36 to 1.5 GHz.
Abstract Josephson parametric amplifiers (JPAs) are used in a wide range of applications, including quantum sensing and axion dark matter searches, due to their near-quantum-limited noise performance. In this article, we present a novel amplifier configuration that increases the frequency scanning range for axion search experiments by combining six narrow-band, flux-driven JPAs. The design consists of two subsets, each comprising three JPAs connected in parallel and coupled to one of two circulators. These subsets are arranged in series. A single pump tone is split and distributed across all JPAs. We effectively mitigated challenges associated with frequency tuning and cross-talk arising from JPA band overlap while maintaining low noise performance. To validate this configuration, we implemented a JPA system spanning 1.2–1.5 GHz as the first-stage amplifier in an RF chain, where the total noise was measured to be approximately twice the standard quantum limit.
We report results of our development of two types of microwave amplifiers based on Superconducting quantum interference devices (SQUIDs) for CAPP (Center for Axion and Precision Physics Research) axion search experiments. The first amplifier, Microstrip SQUID Amplifier (MSA) has a wide bandwidth. Power dissipation in resistive shunts results in a device overheating and limits the MSA performances. A thermal models of shunt cooling processes is developed and recommendations for a future design is provided. The second amplifier, Josephson Parametric Amplifier (JPA), at limited bandwidth showed a low noise near the standard quantum limit (SQL) of 196 mK. Implementation of a JPA in CULTASK (CAPP's Ultra-Low Temperature Axion Search in Korea) experiment is planned in the end of 2019.