Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2305.08866 · International Conference on Low Temperature Physics (LT)

Systematic Approach for Tuning Flux-driven Josephson Parametric Amplifiers for Stochastic Small Signals

Çağlar Kutlu, Saebyeok Ahn, Sergey V. Uchaikin, Soohyung Lee, Arjan F. van Loo, Yasunobu Nakamura, Seonjeong Oh, Yannis Kyriakos Semertzidis

Published May 22, 2023• 2 citations
arXivHTMLPDF

Abstract

Many experiments operating at millikelvin temperatures with signal frequencies in the microwave regime are beginning to incorporate Josephson Parametric Amplifiers (JPA) as their first amplification stage.While there are implementations for a wideband frequency response with a minimal need for tuning, designs using resonant structures with small numbers of Josephson elements still achieve the best noise performance.In a typical measurement scheme involving a JPA, one needs to control the resonance frequency, pump frequency and pump power to achieve the desired amplification and noise properties.In this work, we propose a straightforward approach for operating JPAs with the help of a look-up table (LUT) and online fine-tuning.Using the proposed approach, we demonstrate the operation of a flux-driven JPA with 20 dB gain around 5.9 GHz, covering approximately 100 MHz with 20 kHz tuning steps.The proposed methodology was successfully used in the context of a haloscope axion experiment.

DOI
10.7566/jpscp.38.011202

Related papers

Multi-JPA configuration to broaden amplification bandwidth for axion haloscope experiments

Boris I. Ivanov, Sergey V. Uchaikin, Jinmyeong Kim +7 more

Abstract Josephson parametric amplifiers (JPAs) are used in a wide range of applications, including quantum sensing and axion dark matter searches, due to their near-quantum-limited noise performance. In this article, we present a novel amplifier configuration that increases the frequency scanning range for axion search experiments by combining six narrow-band, flux-driven JPAs. The design consists of two subsets, each comprising three JPAs connected in parallel and coupled to one of two circulators. These subsets are arranged in series. A single pump tone is split and distributed across all JPAs. We effectively mitigated challenges associated with frequency tuning and cross-talk arising from JPA band overlap while maintaining low noise performance. To validate this configuration, we implemented a JPA system spanning 1.2–1.5 GHz as the first-stage amplifier in an RF chain, where the total noise was measured to be approximately twice the standard quantum limit.

Superconductor Science and Technology•Jan 19, 2026•0 citations

Josephson Parametric Amplifier in Axion Experiments

Jinmyeong Kim, Boris I. Ivanov, Çağlar Kutlu +9 more

The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem.Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature.We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta.In our measurements to characterize the JPA we have found the added noise to the system with a JPA as the first-stage amplifier to be lower than 110 mK at the frequencies from 0.938 GHz to 0.963 GHz.

arXiv:2304.04378•International Conference on Low Temperature Physics (LT)•May 22, 2023•4 citations

Characterization of a flux-driven Josephson parametric amplifier with near quantum-limited added noise for axion search experiments

Çağlar Kutlu, Arjan F. van Loo, Sergey V. Uchaikin +7 more

Abstract The experimental non-observation of charge-parity (CP) symmetry violation in quantum chromodynamics is commonly referred to as the strong CP problem. The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors affecting the parameter scanning speed of these detectors is the noise added by the components in the signal detection chain. Since the first amplifier in the chain limits the minimum noise, low-noise amplification is of paramount importance. This paper reports on the operation of a flux-driven Josephson parametric amplifier (JPA) operating at around 2.3 GHz with added noise approaching the quantum limit. The JPA was employed as a first stage amplifier in an experimental setting similar to the ones used in haloscope axion detectors. By operating the JPA at a gain of 19 dB and cascading it with two cryogenic amplifiers operating at 4 K, noise temperatures as low as 120 mK were achieved for the whole signal detection chain.

arXiv:2101.08496•Superconductor Science and Technology•Mar 25, 2021•43 citations

Fabrication of the Impedance-Matched Josephson Parametric Amplifier and the Study of the Gain Profile

Rui Liang Yang, Huiqiu Deng

We designed and fabricated an impedance-matched Josephson parametric amplifier (JPA) working in the flux-pump mode for the broadband amplification of microwave signals. A simple fabrication method suitable for a small cleanroom was developed. We also studied the phase response, as well as the gain, as a function of signal frequency and pump power at various pump frequencies. The phase response can be explained with the behavior of the nonlinear Duffing oscillator. The observed decrease of the resonance frequency as the pump power increases, as well as the emergence of an unstable bifurcation zone, are the characteristic nonlinear behavior of the Duffing oscillator. The features of the gain profile in the stable zone can be explained with a model adapted from the theoretical model for the two-dimensional gain profile of an impedance-matched, current-pumped JPA. Over 17 dB gain with a bandwidth more than 300 MHz (centered around 6.45 GHz) was observed. Our impedance-matched JPA is used for improving the fast readout fidelity of transmon qubits.

arXiv:1909.00707•IEEE Transactions on Applied Superconductivity•Apr 6, 2020•14 citations

Parameter Optimization of Josephson Parametric Amplifiers Using a Heuristic Search Algorithm for Axion Haloscope Search

Young-Geun Kim, Junu Jeong, SungWoo Youn +5 more

The cavity haloscope is among the most widely adopted experimental platforms designed to detect dark matter axions with its principle relying on the conversion of axions into microwave photons in the presence of a strong magnetic field. The Josephson parametric amplifier (JPA), known for its quantum-limited noise characteristics, has been incorporated into the detection system to capture the weakly interacting axion signals. However, the performance of the JPA can be influenced by its environment, leading to the potential unreliability of a predefined parameter set obtained in a specific laboratory setting. Furthermore, conducting a broadband search requires the consecutive characterization of the amplifier across different tuning frequencies. To ensure more reliable measurements, we utilize the Nelder–Mead technique as a numerical search method to dynamically determine the optimal operating conditions. This heuristic search algorithm explores the multidimensional parameter space of the JPA, optimizing critical characteristics such as gain and noise temperature to maximize signal-to-noise ratios for a given experimental setup. Our study presents a comprehensive analysis of the properties of a flux-driven JPA to demonstrate the effectiveness of the algorithm. This approach contributes to ongoing efforts in axion dark matter research by offering an efficient method to enhance axion detection sensitivity through the optimized utilization of JPAs.

arXiv:2404.18345•Electronics•May 29, 2024•3 citations

Broadband lumped-element Josephson parametric amplifier with single-step lithography

T. Elo, T. S. Abhilash, M. R. Perelshtein +3 more

We present a lumped-element Josephson parametric amplifier (JPA) fabricated using a straightforward e-beam lithography process. Our strongly coupled flux-pumped JPA achieves a gain of 20 dB with a bandwidth of 95 MHz around 5 GHz, while the center frequency is tunable by more than 1 GHz, with the additional possibility for rapid tuning by varying the pump frequency alone. Analytical calculations based on the input-output theory reproduce our measurement results closely.

arXiv:1812.07621•Applied Physics Letters•Apr 15, 2019•25 citations
Many experiments operating at millikelvin temperatures with signal frequencies in the microwave regime are beginning to incorporate Josephson Parametric Amplifiers (JPA) as their first amplification stage.While there are implementations for a wideband frequency response with a minimal need for tuning, designs using resonant structures with small numbers of Josephson elements still achieve the best noise performance.In a typical measurement scheme involving a JPA, one needs to control the resonance frequency, pump frequency and pump power to achieve the desired amplification and noise properties.In this work, we propose a straightforward approach for operating JPAs with the help of a look-up table (LUT) and online fine-tuning.Using the proposed approach, we demonstrate the operation of a flux-driven JPA with 20 dB gain around 5.9 GHz, covering approximately 100 MHz with 20 kHz tuning steps.The proposed methodology was successfully used in the context of a haloscope axion experiment.
Abstract Josephson parametric amplifiers (JPAs) are used in a wide range of applications, including quantum sensing and axion dark matter searches, due to their near-quantum-limited noise performance. In this article, we present a novel amplifier configuration that increases the frequency scanning range for axion search experiments by combining six narrow-band, flux-driven JPAs. The design consists of two subsets, each comprising three JPAs connected in parallel and coupled to one of two circulators. These subsets are arranged in series. A single pump tone is split and distributed across all JPAs. We effectively mitigated challenges associated with frequency tuning and cross-talk arising from JPA band overlap while maintaining low noise performance. To validate this configuration, we implemented a JPA system spanning 1.2–1.5 GHz as the first-stage amplifier in an RF chain, where the total noise was measured to be approximately twice the standard quantum limit.
The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem.Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature.We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta.In our measurements to characterize the JPA we have found the added noise to the system with a JPA as the first-stage amplifier to be lower than 110 mK at the frequencies from 0.938 GHz to 0.963 GHz.
Abstract The experimental non-observation of charge-parity (CP) symmetry violation in quantum chromodynamics is commonly referred to as the strong CP problem. The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors affecting the parameter scanning speed of these detectors is the noise added by the components in the signal detection chain. Since the first amplifier in the chain limits the minimum noise, low-noise amplification is of paramount importance. This paper reports on the operation of a flux-driven Josephson parametric amplifier (JPA) operating at around 2.3 GHz with added noise approaching the quantum limit. The JPA was employed as a first stage amplifier in an experimental setting similar to the ones used in haloscope axion detectors. By operating the JPA at a gain of 19 dB and cascading it with two cryogenic amplifiers operating at 4 K, noise temperatures as low as 120 mK were achieved for the whole signal detection chain.
We designed and fabricated an impedance-matched Josephson parametric amplifier (JPA) working in the flux-pump mode for the broadband amplification of microwave signals. A simple fabrication method suitable for a small cleanroom was developed. We also studied the phase response, as well as the gain, as a function of signal frequency and pump power at various pump frequencies. The phase response can be explained with the behavior of the nonlinear Duffing oscillator. The observed decrease of the resonance frequency as the pump power increases, as well as the emergence of an unstable bifurcation zone, are the characteristic nonlinear behavior of the Duffing oscillator. The features of the gain profile in the stable zone can be explained with a model adapted from the theoretical model for the two-dimensional gain profile of an impedance-matched, current-pumped JPA. Over 17 dB gain with a bandwidth more than 300 MHz (centered around 6.45 GHz) was observed. Our impedance-matched JPA is used for improving the fast readout fidelity of transmon qubits.
The cavity haloscope is among the most widely adopted experimental platforms designed to detect dark matter axions with its principle relying on the conversion of axions into microwave photons in the presence of a strong magnetic field. The Josephson parametric amplifier (JPA), known for its quantum-limited noise characteristics, has been incorporated into the detection system to capture the weakly interacting axion signals. However, the performance of the JPA can be influenced by its environment, leading to the potential unreliability of a predefined parameter set obtained in a specific laboratory setting. Furthermore, conducting a broadband search requires the consecutive characterization of the amplifier across different tuning frequencies. To ensure more reliable measurements, we utilize the Nelder–Mead technique as a numerical search method to dynamically determine the optimal operating conditions. This heuristic search algorithm explores the multidimensional parameter space of the JPA, optimizing critical characteristics such as gain and noise temperature to maximize signal-to-noise ratios for a given experimental setup. Our study presents a comprehensive analysis of the properties of a flux-driven JPA to demonstrate the effectiveness of the algorithm. This approach contributes to ongoing efforts in axion dark matter research by offering an efficient method to enhance axion detection sensitivity through the optimized utilization of JPAs.