Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2304.00368 · Optics Letters

Advantages of one- and two-photon light in inverse scattering

Hakob Avetisyan, Vanik E. Mkrtchian, ARMEN E. ALLAHVERDYAN

Published Jun 20, 2023• 1 citation
arXivHTMLPDF

Abstract

We study an inverse scattering problem in which the far-field spectral cross correlation functions of scattered fields are used to determine the unknown dielectric susceptibility of the scattering object. One-photon states for the incident field can resolve (at 100% visibility) twice as many Fourier components of the susceptibility compared with the (naïve) Rayleigh estimate, provided that the measurement is performed in the back-scattering regime. Coherent states are not capable of reaching this optimal resolution (or do so with negligible visibility). Using two-photon states improves upon the one-photon resolution, but the improvement (at 100% visibility) is smaller than twice, and it demands prior information on the object. This improvement can also be realized via two independent laser fields. The dependence on the prior information can be decreased (but not eliminated completely) upon using entangled states of two photons.

DOI
10.1364/ol.492072

Related papers

Quantum imaging and inverse scattering

John C. Schotland

We consider the inverse scattering problem that arises in two-photon quantum imaging with interferometric measurements. We show that the two-point correlation function of the field contains information about the scattering medium at a spatial frequency of twice the Rayleigh bandwidth. The linearized inverse problem, however, yields reconstructions with a resolution of λ/2, where λ is the wavelength of light.

Optics Letters•Oct 7, 2010•9 citations

Sub-Diffraction Near-Field Imaging with Undetected Photons using Thin Sources of Photon Pairs

Elkin A. Santos, Sina Saravi, Andres Vega +2 more

Quantum imaging with undetected photons allows for imaging an object by detecting photons that never interacted with it, using the correlation between photon pairs generated in the process of spontaneous parametric down conversion (SPDC) [1] . Through SPDC in a χ (2) material, a pump (P) photon of wavelength λ P can split into a pair of signal (S) and idler (I) photons, such that 1/ λ P = 1/ λ S + 1/ λ I . In such imaging schemes, the object’s optical properties at λ I , such as its absorption profile, can be inferred by only imaging the signal photons. Thus, one can image in challenging spectral ranges, such as mid-IR for λ I , using detectors in the visible for λ S [1] . In this scheme, the resolution is fundamentally diffraction-limited to the wavelength that interacts with the object, λ I [2] . We show that one can go beyond this diffraction limit by placing the object in the near-field of a subwavelength thin SPDC source, as shown schematically in Fig. 1(a) , through transferring the near-field information at λ I into propagating modes at λ S that can be detected in the far field. In this scheme, the resolution of imaging the object at λ I is determined by the detected signal wavelength λ S . As an application, we numerically demonstrate how two closely-spaced small scatterers at mid-IR can be resolved with a visible-range resolution.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•0 citations

Quantum microscopy using photon correlations

Ashok Muthukrishnan, Marlan O. Scully, Muhammad Suhail Zubairy

Higher-order correlations of the radiation field improve resolution in stellar interferometers, as in the Hanbury-Brown–Twiss effect. It is also possible to improve microscopic resolution beyond the Rayleigh limit by using quantum light fields composed of entangled photons. Focusing on two photons, we distinguish two types of entanglement: frequency entanglement, where the photons in different paths are correlated in frequency, and path entanglement, where the correlation between paths is in photon number. Two paradigms of quantum microscopy are discussed: spectral microscopy, where path- and frequency-entangled photons produced in cascade decay of two atoms make possible sub-natural linewidth resolution of atomic levels, and spatial microscopy, where path-entangled photons emitted by an atomic array produce sub-wavelength diffraction resolution as compared to an equivalent classical grating. These scenarios require two-photon correlation or coincidence measurements. The connection between the two paradigms, and the two types of entanglement, highlights the link between the temporal and spatial aspects of quantum interferometry.

Journal of Optics B Quantum and Semiclassical Optics•May 29, 2004•41 citations

Scattering of entangled two-photon states

John C. Schotland, A. Cazé, Theodore B. Norris

We consider the scattering of entangled two-photon states from collections of small particles. We also study the related Mie problem of scattering from a sphere. In both cases, we calculate the entropy of entanglement and investigate the influence of the entanglement of the incident field on the entanglement of the scattered field.

arXiv:1509.07931•Optics Letters•Jan 15, 2016•16 citations

Quantum field theory and inverse problems: Imaging with Entangled Photons

Matti J. Lassas, Medet Nursultanov, Lauri Oksanen +1 more

We consider the quantum field theory for a scalar model of the electromagnetic field interacting with a system of two-level atoms. In this setting, we show that it is possible to uniquely determine the density of atoms from measurements of the source to solution map for a system of nonlocal partial differential equations, which describe the scattering of a two-photon state from the atoms. The required measurements involve correlating the outputs of a point detector with an integrating detector, thereby exploiting information about the entanglement of the photons.

arXiv:2506.03653•Jun 4, 2025•0 citations

Resolution and Contrast Enhancement of Correlated Imaging in Photon Counting Regime

Feng Wen, Xun Zhang, Chenzhi Yuan +4 more

We theoretically discuss the four-photon spatial correlation property under different detection schemes. Compared with the two- and three-photon spatial correlation of thermal light source, we found that the enhancement in the visibility and the contrast when the fourth-order spatial correlation function is measured with quadruple coincidence measurement in the single photon counting regime. The resolution, however, is not changed when we scan three of four detectors with identical speed and direction. But if we scan two of three detectors in opposite directions and same speed, simultaneously, other two in identical direction and speed of one detector is twice of that of the other, we can see that both the contrast and resolution are improved significantly. We also show that the conclusion can be applied to the Nth-order ghost imaging.

Journal of the Physical Society of Japan•Sep 24, 2014•4 citations
We study an inverse scattering problem in which the far-field spectral cross correlation functions of scattered fields are used to determine the unknown dielectric susceptibility of the scattering object. One-photon states for the incident field can resolve (at 100% visibility) twice as many Fourier components of the susceptibility compared with the (naïve) Rayleigh estimate, provided that the measurement is performed in the back-scattering regime. Coherent states are not capable of reaching this optimal resolution (or do so with negligible visibility). Using two-photon states improves upon the one-photon resolution, but the improvement (at 100% visibility) is smaller than twice, and it demands prior information on the object. This improvement can also be realized via two independent laser fields. The dependence on the prior information can be decreased (but not eliminated completely) upon using entangled states of two photons.
Quantum imaging with undetected photons allows for imaging an object by detecting photons that never interacted with it, using the correlation between photon pairs generated in the process of spontaneous parametric down conversion (SPDC) [1] . Through SPDC in a χ (2) material, a pump (P) photon of wavelength λ P can split into a pair of signal (S) and idler (I) photons, such that 1/ λ P = 1/ λ S + 1/ λ I . In such imaging schemes, the object’s optical properties at λ I , such as its absorption profile, can be inferred by only imaging the signal photons. Thus, one can image in challenging spectral ranges, such as mid-IR for λ I , using detectors in the visible for λ S [1] . In this scheme, the resolution is fundamentally diffraction-limited to the wavelength that interacts with the object, λ I [2] . We show that one can go beyond this diffraction limit by placing the object in the near-field of a subwavelength thin SPDC source, as shown schematically in Fig. 1(a) , through transferring the near-field information at λ I into propagating modes at λ S that can be detected in the far field. In this scheme, the resolution of imaging the object at λ I is determined by the detected signal wavelength λ S . As an application, we numerically demonstrate how two closely-spaced small scatterers at mid-IR can be resolved with a visible-range resolution.
Higher-order correlations of the radiation field improve resolution in stellar interferometers, as in the Hanbury-Brown–Twiss effect. It is also possible to improve microscopic resolution beyond the Rayleigh limit by using quantum light fields composed of entangled photons. Focusing on two photons, we distinguish two types of entanglement: frequency entanglement, where the photons in different paths are correlated in frequency, and path entanglement, where the correlation between paths is in photon number. Two paradigms of quantum microscopy are discussed: spectral microscopy, where path- and frequency-entangled photons produced in cascade decay of two atoms make possible sub-natural linewidth resolution of atomic levels, and spatial microscopy, where path-entangled photons emitted by an atomic array produce sub-wavelength diffraction resolution as compared to an equivalent classical grating. These scenarios require two-photon correlation or coincidence measurements. The connection between the two paradigms, and the two types of entanglement, highlights the link between the temporal and spatial aspects of quantum interferometry.
We consider the quantum field theory for a scalar model of the electromagnetic field interacting with a system of two-level atoms. In this setting, we show that it is possible to uniquely determine the density of atoms from measurements of the source to solution map for a system of nonlocal partial differential equations, which describe the scattering of a two-photon state from the atoms. The required measurements involve correlating the outputs of a point detector with an integrating detector, thereby exploiting information about the entanglement of the photons.
We theoretically discuss the four-photon spatial correlation property under different detection schemes. Compared with the two- and three-photon spatial correlation of thermal light source, we found that the enhancement in the visibility and the contrast when the fourth-order spatial correlation function is measured with quadruple coincidence measurement in the single photon counting regime. The resolution, however, is not changed when we scan three of four detectors with identical speed and direction. But if we scan two of three detectors in opposite directions and same speed, simultaneously, other two in identical direction and speed of one detector is twice of that of the other, we can see that both the contrast and resolution are improved significantly. We also show that the conclusion can be applied to the Nth-order ghost imaging.