Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Sub-Diffraction Near-Field Imaging with Undetected Photons using Thin Sources of Photon Pairs

Elkin A. Santos, Sina Saravi, Andres Vega, Thomas Pertsch, Frank Setzpfandt

Published Jun 21, 2021• 0 citations
Publisher

Abstract

Quantum imaging with undetected photons allows for imaging an object by detecting photons that never interacted with it, using the correlation between photon pairs generated in the process of spontaneous parametric down conversion (SPDC) [1] . Through SPDC in a χ (2) material, a pump (P) photon of wavelength λ P can split into a pair of signal (S) and idler (I) photons, such that 1/ λ P = 1/ λ S + 1/ λ I . In such imaging schemes, the object’s optical properties at λ I , such as its absorption profile, can be inferred by only imaging the signal photons. Thus, one can image in challenging spectral ranges, such as mid-IR for λ I , using detectors in the visible for λ S [1] . In this scheme, the resolution is fundamentally diffraction-limited to the wavelength that interacts with the object, λ I [2] . We show that one can go beyond this diffraction limit by placing the object in the near-field of a subwavelength thin SPDC source, as shown schematically in Fig. 1(a) , through transferring the near-field information at λ I into propagating modes at λ S that can be detected in the far field. In this scheme, the resolution of imaging the object at λ I is determined by the detected signal wavelength λ S . As an application, we numerically demonstrate how two closely-spaced small scatterers at mid-IR can be resolved with a visible-range resolution.

DOI
10.1109/cleo/europe-eqec52157.2021.9542305

Related papers

Subwavelength-resolution Imaging with Undetected Photons using Thin Sources of Photon Pairs

Elkin A. Santos, Sina Saravi, Thomas Pertsch +1 more

We present an imaging scheme with undetected photons that overcomes the diffraction limit by transferring near-field information at the wavelength that illuminates the object to the far-field of its paired wavelength generated in a thin photon-pair source.

Quantum Information and Measurement (QIM)•Jan 1, 2021•0 citations

Subdiffraction Quantum Imaging with Undetected Photons

Elkin A. Santos, Thomas Pertsch, Frank Setzpfandt +1 more

We propose a nonlinear imaging scheme with undetected photons that overcomes the diffraction limit by transferring near-field information at one wavelength to far-field information of a correlated photon with a different wavelength generated through spontaneous photon-pair generation. At the same time, this scheme allows for retrieval of high-contrast images with zero background, making it a highly sensitive scheme for imaging of small objects at challenging spectral ranges with subdiffraction resolutions.

arXiv:2203.11050•Physical Review Letters•Apr 27, 2022•22 citations

Quantum metrology with undetected mid-infrared photons for applied non-destructive testing

Paul Gattinger, Andreas W. Schell, Maja Buchegger +2 more

Metrology with undetected photons is an emerging technique that leverages quantum effects and photon correlations (entanglement) to retrieve valuable information in a target spectral range (e.g., mid-infrared, mid-IR) using measurements in an easily accessible domain (e.g., visible, near-IR). The underlying quantum process of spontaneous parametric down-conversion (SPDC) is utilized to generate non-degenerate correlated signal and idler photons to serve as detection and probing photons, respectively. Sensing with undetected photons enables important advantages, such as ultra-low probe powers, room-temperature operation, and shot-noise-limited detection. In this contribution, we apply a quantum nonlinear interferometer based on an SPDC source to perform applied mid-IR spectroscopy, mid-IR microscopy, and mid-IR optical coherence tomography (OCT) as among the most promising techniques for quantum-based routine non-destructive testing. Moreover, we characterize the system, benchmark it against classical systems, and provide a prospective outlook for this new technology.

quant-pharXiv:2607.12653•e+i Elektrotechnik und Informationstechnik•Jul 15, 2026•0 citations

Fundamental resolution limit of quantum imaging with undetected photons

Andres Vega, Elkin A. Santos, Jorge Fuenzalida +5 more

Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows us to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this nonlocal imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other nonlocal two-photon imaging schemes.

arXiv:2203.06106•Physical Review Research•Sep 30, 2022•28 citations

New progress in quantum imaging with undetected photons (Conference Presentation)

Markus Gräfe, Marta Gilaberte Basset, Josué R. León Torres

Since the second quantum revolution, the growing exploitation of quantum states led to many sophisticated and novel applications [Phil. Trans. R. Soc. Lond. A 361, 1655 (2003). Former, mainly academic research is more and more transferred into real-world quantum technology ready to serve practical tasks. Today, the quantum computer is within reach, satellite based quantum communication already started, and the field of sensing and imaging was revolutionized, too. Non-classical states of light promise a phase sensitivity beyond any classical possibility [PRL 112, 103604 (2014)] and super-resolution capability [Nature Commun. 8, 14786 (2017)]. Moreover, based on quantum correlations, which are rooted in the very heart of quantum mechanics, the imaging of samples with photons that have never interacted with the object is feasible. This science fiction like phenomenon was first investigated by Mandel [PRA 44, 4614 (1991)] and later implemented for actual imaging purposes in the Zeilinger group [Nature 512, 409 (2014)]. We are going to present the transfer of this approach into applicable quantum technology within the realm of the Fraunhofer Key Research Initiative Quantum Methods for Advanced Imaging Solutions (QUILT). The method itself is based on induced coherence without induced emission [PRA 44, 4614 (1991)]. We built a novel compact implementation of this scheme based on only one nonlinear crystal. The crystal is coherently pumped by a laser from two sides such that signal and idler photon pairs can be collinearly emitted in either of two opposite directions (to the right or to the left). On the right side the idler beam will be separated by a dichroic mirror (DM) and interacts with an object (directly placed in front of a mirror or reflective object). On the left side the signal beam will be separated by another dichroic mirror and hit the camera, which is either a sCMOS or an EMCCD. Additional lenses provide the particular imaging. Sine the two possibilities for the idler beam – going right and interact with the object or going left from the nonlinear crystal – interfere the object could be observed by idler detection. However, the same interference can be observed for the signal beams although the never interacted with the object. Hence, the object can be imaged by detecting the signal light only. The crucial point here is the lack of wich-path information of the idler beams in this type of Michelson interferometric setup. The following points should be emphasized: (i) the signal channels never interact with the object, (ii) there is no induced emission due to the idler beam that interacted with the object, and (iii) there is no coincidence detection involved in this scheme. The obvious advantage of this technique is that the wavelength of the idler photons can be tailored to match the interesting spectral range for interaction with the object. At the same time, the signal photons, which are actually detected, can stay in the VIS range where, e.g., Si-based detectors are optimized. Besides the application for life science imaging, we are comparing the quantum imaging properties utilizing momentum correlations or spatial correlations, where the ladder is a modus that was never investigated before. As an outlook we work on significantly enhance SPDC sources in scope of quantum performance and wavelength separation. Obviously, pushing the short-wavelength idler photons further into the deep UV or XUV broadens the range of applications, but must be implemented by non-SPDC photon pair sources.

Quantum Communications and Quantum Imaging•Sep 10, 2019•0 citations

Mid-infrared microscopy via position correlations of undetected photons

Inna Kviatkovsky, Helen M. Chrzanowski, Sven Ramelow

Quantum imaging with undetected photons (QIUP) has recently emerged as a new powerful imaging tool. Exploiting the spatial entanglement of photon pairs, it allows decoupling of the sensing and detection wavelengths, facilitating imaging in otherwise challenging spectral regions by leveraging mature silicon-based detection technology. All existing implementations of QIUP have so far utilised the momentum correlations within the biphoton states produced by spontaneous parametric downconversion. Here, for the first time, we implement and examine theoretically and numerically the complementary scenario - utilising the tight position correlations formed within photon pairs at birth. This image plane arrangement facilitates high resolution imaging with comparative experimental ease, and we experimentally show resolutions below 10 μm at a sensing wavelength of 3.7 μm. Moreover, we present a quantitative numerical model predicting the imaging capabilities of QIUP for a wide range of parameters. Finally, by imaging mouse heart tissue at the mid-IR to reveal morphological features on the cellular level, we further demonstrate the viability of this technique for the life sciences. These results offer new perspectives on the capabilities of QIUP for label-free widefield mid-IR microscopy, enabling real-world biomedical as well as industrial imaging applications.

arXiv:2106.06435•Optics Express•Dec 13, 2021•40 citations
Quantum imaging with undetected photons allows for imaging an object by detecting photons that never interacted with it, using the correlation between photon pairs generated in the process of spontaneous parametric down conversion (SPDC) [1] . Through SPDC in a χ (2) material, a pump (P) photon of wavelength λ P can split into a pair of signal (S) and idler (I) photons, such that 1/ λ P = 1/ λ S + 1/ λ I . In such imaging schemes, the object’s optical properties at λ I , such as its absorption profile, can be inferred by only imaging the signal photons. Thus, one can image in challenging spectral ranges, such as mid-IR for λ I , using detectors in the visible for λ S [1] . In this scheme, the resolution is fundamentally diffraction-limited to the wavelength that interacts with the object, λ I [2] . We show that one can go beyond this diffraction limit by placing the object in the near-field of a subwavelength thin SPDC source, as shown schematically in Fig. 1(a) , through transferring the near-field information at λ I into propagating modes at λ S that can be detected in the far field. In this scheme, the resolution of imaging the object at λ I is determined by the detected signal wavelength λ S . As an application, we numerically demonstrate how two closely-spaced small scatterers at mid-IR can be resolved with a visible-range resolution.
We propose a nonlinear imaging scheme with undetected photons that overcomes the diffraction limit by transferring near-field information at one wavelength to far-field information of a correlated photon with a different wavelength generated through spontaneous photon-pair generation. At the same time, this scheme allows for retrieval of high-contrast images with zero background, making it a highly sensitive scheme for imaging of small objects at challenging spectral ranges with subdiffraction resolutions.
Metrology with undetected photons is an emerging technique that leverages quantum effects and photon correlations (entanglement) to retrieve valuable information in a target spectral range (e.g., mid-infrared, mid-IR) using measurements in an easily accessible domain (e.g., visible, near-IR). The underlying quantum process of spontaneous parametric down-conversion (SPDC) is utilized to generate non-degenerate correlated signal and idler photons to serve as detection and probing photons, respectively. Sensing with undetected photons enables important advantages, such as ultra-low probe powers, room-temperature operation, and shot-noise-limited detection. In this contribution, we apply a quantum nonlinear interferometer based on an SPDC source to perform applied mid-IR spectroscopy, mid-IR microscopy, and mid-IR optical coherence tomography (OCT) as among the most promising techniques for quantum-based routine non-destructive testing. Moreover, we characterize the system, benchmark it against classical systems, and provide a prospective outlook for this new technology.
Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows us to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this nonlocal imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other nonlocal two-photon imaging schemes.
Since the second quantum revolution, the growing exploitation of quantum states led to many sophisticated and novel applications [Phil. Trans. R. Soc. Lond. A 361, 1655 (2003). Former, mainly academic research is more and more transferred into real-world quantum technology ready to serve practical tasks. Today, the quantum computer is within reach, satellite based quantum communication already started, and the field of sensing and imaging was revolutionized, too. Non-classical states of light promise a phase sensitivity beyond any classical possibility [PRL 112, 103604 (2014)] and super-resolution capability [Nature Commun. 8, 14786 (2017)]. Moreover, based on quantum correlations, which are rooted in the very heart of quantum mechanics, the imaging of samples with photons that have never interacted with the object is feasible. This science fiction like phenomenon was first investigated by Mandel [PRA 44, 4614 (1991)] and later implemented for actual imaging purposes in the Zeilinger group [Nature 512, 409 (2014)]. We are going to present the transfer of this approach into applicable quantum technology within the realm of the Fraunhofer Key Research Initiative Quantum Methods for Advanced Imaging Solutions (QUILT). The method itself is based on induced coherence without induced emission [PRA 44, 4614 (1991)]. We built a novel compact implementation of this scheme based on only one nonlinear crystal. The crystal is coherently pumped by a laser from two sides such that signal and idler photon pairs can be collinearly emitted in either of two opposite directions (to the right or to the left). On the right side the idler beam will be separated by a dichroic mirror (DM) and interacts with an object (directly placed in front of a mirror or reflective object). On the left side the signal beam will be separated by another dichroic mirror and hit the camera, which is either a sCMOS or an EMCCD. Additional lenses provide the particular imaging. Sine the two possibilities for the idler beam – going right and interact with the object or going left from the nonlinear crystal – interfere the object could be observed by idler detection. However, the same interference can be observed for the signal beams although the never interacted with the object. Hence, the object can be imaged by detecting the signal light only. The crucial point here is the lack of wich-path information of the idler beams in this type of Michelson interferometric setup. The following points should be emphasized: (i) the signal channels never interact with the object, (ii) there is no induced emission due to the idler beam that interacted with the object, and (iii) there is no coincidence detection involved in this scheme. The obvious advantage of this technique is that the wavelength of the idler photons can be tailored to match the interesting spectral range for interaction with the object. At the same time, the signal photons, which are actually detected, can stay in the VIS range where, e.g., Si-based detectors are optimized. Besides the application for life science imaging, we are comparing the quantum imaging properties utilizing momentum correlations or spatial correlations, where the ladder is a modus that was never investigated before. As an outlook we work on significantly enhance SPDC sources in scope of quantum performance and wavelength separation. Obviously, pushing the short-wavelength idler photons further into the deep UV or XUV broadens the range of applications, but must be implemented by non-SPDC photon pair sources.
Quantum imaging with undetected photons (QIUP) has recently emerged as a new powerful imaging tool. Exploiting the spatial entanglement of photon pairs, it allows decoupling of the sensing and detection wavelengths, facilitating imaging in otherwise challenging spectral regions by leveraging mature silicon-based detection technology. All existing implementations of QIUP have so far utilised the momentum correlations within the biphoton states produced by spontaneous parametric downconversion. Here, for the first time, we implement and examine theoretically and numerically the complementary scenario - utilising the tight position correlations formed within photon pairs at birth. This image plane arrangement facilitates high resolution imaging with comparative experimental ease, and we experimentally show resolutions below 10 μm at a sensing wavelength of 3.7 μm. Moreover, we present a quantitative numerical model predicting the imaging capabilities of QIUP for a wide range of parameters. Finally, by imaging mouse heart tissue at the mid-IR to reveal morphological features on the cellular level, we further demonstrate the viability of this technique for the life sciences. These results offer new perspectives on the capabilities of QIUP for label-free widefield mid-IR microscopy, enabling real-world biomedical as well as industrial imaging applications.