arXiv:2301.00994 · Applied Physics Letters

Pinhole quantum ghost imaging

Andres Vega, Sina Saravi, Thomas Pertsch, Frank Setzpfandt

Published Aug 31, 2020• 6 citations
arXivHTMLPDF

Abstract

We propose a quantum ghost imaging scheme based on biphotons, which, by using a collimated pump beam of the right size for biphoton generation, obviates the need for lenses to achieve imaging. The scheme is found to be analogous to the classical pinhole camera, where we show that the equivalent to the classical pinhole size depends not only mainly on the width of the pump beam but also on the thickness of the nonlinear crystal and the wavelengths of the biphoton.

DOI
10.1063/5.0012477

Related papers

Observation of two-color ghost imaging

Sanjit Karmakar, Yanhua H. Shih

Two-photon quantum imaging has so far demonstrated two peculiar features: (1) reproducing nonlocal images in "ghost" imaging type experiments and (2) improving imaging spatial resolution beyond the classical limit in quantum lithography type measurements. This article reports an experimental study on non-degenerate, two-color, biphoton ghost imaging which reproduced a nonlocal ghost image and simultaneously enhanced the angular resolving power of imaging by means of a greater field of view or by means of a greater imaging amplification compared with that of classical imaging.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 2, 2010•7 citations

Quantum ghost imaging using asynchronous detection

Carsten Pitsch, Dominik Walter, Simon Grosse +3 more

We present first results of a novel type of setup for quantum ghost imaging based on asynchronous single photon timing using single photon avalanche diode (SPAD) detectors. This scheme enables photon pairing with arbitrary path length difference and does, therefore, obviate the dependence on optical delay lines of current quantum ghost imaging setups [Nat. Commun.6, 5913 (2015)NCAOBW2041-172310.1038/ncomms6913]. It is also, to our knowledge, the first quantum ghost imaging setup to allow three-dimensional imaging.

Applied Optics•May 24, 2021•24 citations

Interaction-free quantum imaging

Yingwen Zhang, Lu Gao, Alicia Sit +8 more

Quantum imaging attempts to exploit the quantum features of light in order to enhance one or more aspects of classical imaging. Here we focus on two quantum imaging schemes – ghost imaging and interaction-free imaging – and moreover, on their combination. After a brief overview of the subject we report the main result: a laboratory demonstration of a new imaging scheme termed Interaction-Free Ghost Imaging. We then explain its merits for the task of imaging various structured objects. Next, we discuss an outgrowth of this scheme used for the purpose of nonlocal quantum erasure. We conclude by mentioning some related, low-dose schemes (both quantum and quantum-inspired) for X-ray and gammaray sources.

Nanoscale Imaging, Sensing, and Actuation for Biomedical Applications•Feb 21, 2020•3 citations

Confocal imaging from biphoton correlations

Euan Millar, Emma Pearce, Daniele Faccio +1 more

Confocal microscopy provides optical sectioning for three-dimensional imaging but conventionally relies on point-by-point scanning and physical pinholes, limiting imaging speed. Here, we demonstrate that confocal sectioning can instead arise directly from quantum measurement, using spatial correlations in entangled biphoton states. Spatially resolved coincidence measurements in a widefield imaging system suppress contributions from out-of-focus planes, producing optical sectioning in parallel across the whole field of view without physical pinholes or mechanical scanning. In addition, this quantum approach obtains an axial response that, as a result of position-momentum entanglement, is $\sqrt{2}$-times narrower than that of classical confocal imaging. Our work establishes biphoton correlations as a mechanism for improved confocal imaging and enables parallel, pinhole-free optical sectioning without mechanical scanning.

physics.opticsCross-listedarXiv:2609.39954•Oct 1, 2026•0 citations

Phase-sensitive coherence and the classical-quantum boundary in ghost imaging

Baris I. Erkmen, Nicholas D. Hardy, Dheera Venkatraman +2 more

The theory of partial coherence has a long and storied history in classical statistical optics. The vast majority of this work addresses fields that are statistically stationary in time, hence their complex envelopes only have phase-insensitive correlations. The quantum optics of squeezed-state generation, however, depends on nonlinear interactions producing baseband field operators with phase-insensitive and phase-sensitive correlations. Utilizing quantum light to enhance imaging has been a topic of considerable current interest, much of it involving biphotons, i.e., streams of entangled-photon pairs. Biphotons have been employed for quantum versions of optical coherence tomography, ghost imaging, holography, and lithography. However, their seemingly quantum features have been mimicked with classical-state light, questioning wherein lies the classical-quantum boundary. We have shown, for the case of Gaussian-state light, that this boundary is intimately connected to the theory of phase-sensitive partial coherence. Here we present that theory, contrasting it with the familiar case of phase-insensitive partial coherence, and use it to elucidate the classical-quantum boundary of ghost imaging. We show, both theoretically and experimentally, that classical phase-sensitive light produces ghost images most closely mimicking those obtained with biphotons, and we derive the spatial resolution, image contrast, and signal-to-noise ratio of a standoff-sensing ghost imager, taking into account target-induced speckle.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 8, 2011•2 citations

Quantum Ghost Imaging of remote targets with a SPAD camera

Massimiliano Proietti, Alessia Suprano, Francesco Poggiali +9 more

Quantum Ghost Imaging exploits entangled photons to image a target. Standard approaches require to know the target’s distance a priori, making it unpractical. We exploit a novel SPAD camera, to surpass such limitation.

Quantum 2.0 Conference and Exhibition•Jan 1, 2025•0 citations
We propose a quantum ghost imaging scheme based on biphotons, which, by using a collimated pump beam of the right size for biphoton generation, obviates the need for lenses to achieve imaging. The scheme is found to be analogous to the classical pinhole camera, where we show that the equivalent to the classical pinhole size depends not only mainly on the width of the pump beam but also on the thickness of the nonlinear crystal and the wavelengths of the biphoton.
Two-photon quantum imaging has so far demonstrated two peculiar features: (1) reproducing nonlocal images in "ghost" imaging type experiments and (2) improving imaging spatial resolution beyond the classical limit in quantum lithography type measurements. This article reports an experimental study on non-degenerate, two-color, biphoton ghost imaging which reproduced a nonlocal ghost image and simultaneously enhanced the angular resolving power of imaging by means of a greater field of view or by means of a greater imaging amplification compared with that of classical imaging.
We present first results of a novel type of setup for quantum ghost imaging based on asynchronous single photon timing using single photon avalanche diode (SPAD) detectors. This scheme enables photon pairing with arbitrary path length difference and does, therefore, obviate the dependence on optical delay lines of current quantum ghost imaging setups [Nat. Commun.6, 5913 (2015)NCAOBW2041-172310.1038/ncomms6913]. It is also, to our knowledge, the first quantum ghost imaging setup to allow three-dimensional imaging.
Quantum imaging attempts to exploit the quantum features of light in order to enhance one or more aspects of classical imaging. Here we focus on two quantum imaging schemes – ghost imaging and interaction-free imaging – and moreover, on their combination. After a brief overview of the subject we report the main result: a laboratory demonstration of a new imaging scheme termed Interaction-Free Ghost Imaging. We then explain its merits for the task of imaging various structured objects. Next, we discuss an outgrowth of this scheme used for the purpose of nonlocal quantum erasure. We conclude by mentioning some related, low-dose schemes (both quantum and quantum-inspired) for X-ray and gammaray sources.
Confocal microscopy provides optical sectioning for three-dimensional imaging but conventionally relies on point-by-point scanning and physical pinholes, limiting imaging speed. Here, we demonstrate that confocal sectioning can instead arise directly from quantum measurement, using spatial correlations in entangled biphoton states. Spatially resolved coincidence measurements in a widefield imaging system suppress contributions from out-of-focus planes, producing optical sectioning in parallel across the whole field of view without physical pinholes or mechanical scanning. In addition, this quantum approach obtains an axial response that, as a result of position-momentum entanglement, is 2\sqrt{2}2​-times narrower than that of classical confocal imaging. Our work establishes biphoton correlations as a mechanism for improved confocal imaging and enables parallel, pinhole-free optical sectioning without mechanical scanning.
The theory of partial coherence has a long and storied history in classical statistical optics. The vast majority of this work addresses fields that are statistically stationary in time, hence their complex envelopes only have phase-insensitive correlations. The quantum optics of squeezed-state generation, however, depends on nonlinear interactions producing baseband field operators with phase-insensitive and phase-sensitive correlations. Utilizing quantum light to enhance imaging has been a topic of considerable current interest, much of it involving biphotons, i.e., streams of entangled-photon pairs. Biphotons have been employed for quantum versions of optical coherence tomography, ghost imaging, holography, and lithography. However, their seemingly quantum features have been mimicked with classical-state light, questioning wherein lies the classical-quantum boundary. We have shown, for the case of Gaussian-state light, that this boundary is intimately connected to the theory of phase-sensitive partial coherence. Here we present that theory, contrasting it with the familiar case of phase-insensitive partial coherence, and use it to elucidate the classical-quantum boundary of ghost imaging. We show, both theoretically and experimentally, that classical phase-sensitive light produces ghost images most closely mimicking those obtained with biphotons, and we derive the spatial resolution, image contrast, and signal-to-noise ratio of a standoff-sensing ghost imager, taking into account target-induced speckle.