Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Phase-sensitive coherence and the classical-quantum boundary in ghost imaging

Baris I. Erkmen, Nicholas D. Hardy, Dheera Venkatraman, Franco N. C. Wong, Jeffrey H. Shapiro

Published Sep 8, 2011• 2 citations
Publisher

Abstract

The theory of partial coherence has a long and storied history in classical statistical optics. The vast majority of this work addresses fields that are statistically stationary in time, hence their complex envelopes only have phase-insensitive correlations. The quantum optics of squeezed-state generation, however, depends on nonlinear interactions producing baseband field operators with phase-insensitive and phase-sensitive correlations. Utilizing quantum light to enhance imaging has been a topic of considerable current interest, much of it involving biphotons, i.e., streams of entangled-photon pairs. Biphotons have been employed for quantum versions of optical coherence tomography, ghost imaging, holography, and lithography. However, their seemingly quantum features have been mimicked with classical-state light, questioning wherein lies the classical-quantum boundary. We have shown, for the case of Gaussian-state light, that this boundary is intimately connected to the theory of phase-sensitive partial coherence. Here we present that theory, contrasting it with the familiar case of phase-insensitive partial coherence, and use it to elucidate the classical-quantum boundary of ghost imaging. We show, both theoretically and experimentally, that classical phase-sensitive light produces ghost images most closely mimicking those obtained with biphotons, and we derive the spatial resolution, image contrast, and signal-to-noise ratio of a standoff-sensing ghost imager, taking into account target-induced speckle.

DOI
10.1117/12.893151

Related papers

Unified theory of ghost imaging with Gaussian-state light

Baris I. Erkmen, Jeffrey H. Shapiro

The theory of ghost imaging is developed in a Gaussian-state framework that both encompasses prior work---on thermal-state and biphoton-state imagers---and provides a complete understanding of the boundary between classical and quantum behavior in such systems. The core of this analysis is the expression derived for the photocurrent-correlation image obtained using a general Gaussian-state source. This image is expressed in terms of the phase-insensitive and phase-sensitive cross correlations between the two detected fields, plus a background. Because any pair of cross correlations is obtainable with classical Gaussian states, the image does not carry a quantum signature per se. However, if the image characteristics of classical and nonclassical Gaussian-state sources with identical autocorrelation functions are compared, the nonclassical source provides resolution improvement in its near field and field-of-view improvement in its far field.

arXiv:0712.3554•Physical Review A•Apr 7, 2008•181 citations

Reflective ghost imaging with classical Gaussian-state light

Deyang Duan, Yunjie Xia Yunjie Xia

In this letter, we use quantum description and the Gaussian state to study reflective ghost imaging with two classical sources, and to provide their expressions.We find that the reflective ghost imaging of a roughsurfaced object, using Gaussian-state phase-insensitive or classically correlated phase-sensitive light, can be expressed in terms of the phase-insensitive or phase-sensitive cross-correlations between the two detected fields, including a background term.Moreover, reflective ghost imaging with two classical Gaussian-state lights is shown to have similar features as spatial resolution and field of view.

Chinese Optics Letters•Jan 1, 2012•4 citations

Reflective ghost imaging with classical Gaussian-state light

段德洋, 夏云杰

In this letter,we use quantum description and the Gaussian state to study reflective ghost imaging with two classical sources,and to provide their expressions.We find that the reflective ghost imaging of a roughsurfaced object,using Gaussian-state phase-insensitive or classically correlated phase-sensitive light,can be expressed in terms of the phase-insensitive or phase-sensitive cross-correlations between the two detected fields,including a background term.Moreover,reflective ghost imaging with two classical Gaussian-state lights is shown to have similar features as spatial resolution and field of view.

Chinese Optics Letters•Jan 1, 2012•0 citations

Ghost Imaging: What is quantum, what is not

Baris I. Erkmen, Jeffrey H. Shapiro

We provide a unified treatment of classical and quantum Gaussian-state sources that unambiguously identifies which features of ghost imaging are strictly quantum mechanical. We show that ghost-image formation is fundamentally classical, with the image being expressible in terms of the phase-insensitive and phase-sensitive cross correlations between the detected fields. We then consider ghost-imaging scenarios with either phase-insensitive or phase-sensitive sources, where the former are always classical but the latter may be classical or quantum mechanical. We show that if their auto-correlations are identical, then a quantum source provides resolution improvement in its near-field and field-of-view improvement in its far field when compared to a classical source.

arXiv:quant-ph/0612070•Dec 10, 2006•4 citations

Signal-to-Noise Ratio of Gaussian-State Ghost Imaging

Baris I. Erkmen, Jeffrey H. Shapiro

The signal-to-noise ratios (SNRs) of three Gaussian-state ghost-imaging configurations---distinguished by the nature of their light sources---are derived. Two use classical-state light, specifically a joint signal-reference field state that has either the maximum phase-insensitive or the maximum phase-sensitive cross correlation consistent with having a proper $P$ representation. The third uses nonclassical light, in particular an entangled signal-reference field state with the maximum phase-sensitive cross correlation permitted by quantum mechanics. Analytic SNR expressions are developed for the near-field and far-field regimes, within which simple asymptotic approximations are presented for low-brightness and high-brightness sources. A high-brightness thermal-state (classical phase-insensitive state) source will typically achieve a higher SNR than a biphoton-state (low-brightness, low-flux limit of the entangled-state) source, when all other system parameters are equal for the two systems. With high efficiency photon-number-resolving detectors, a low-brightness, high-flux entangled-state source may achieve a higher SNR than that obtained with a high-brightness thermal-state source.

arXiv:0809.4167•Physical Review A•Jan 1, 2009•130 citations

Interaction-free ghost-imaging of structured objects (Conference Presentation)

Yingwen Zhang, Alicia Sit, Frédéric Bouchard +6 more

Correlated light (either classical or quantum) can be employed in various ways to improve resolution and measurement sensitivity. In an “interaction-free” measurement, a single photon can be used to reveal the presence of an object placed within one arm of an interferometer without being absorbed by it. This method has previously been applied to imaging. With a technique known as “ghost imaging”, entangled photon pairs are used for detecting an opaque object with significantly improved signal-to-noise ratio while preventing over-illumination. Here, we integrate these two methods to obtain a new imaging technique which we term “interaction-free ghost-imaging” that possesses the benefits of both techniques. While improving the image quality of conventional ghost-imaging, this new technique is also sensitive to phase and polarization changes in the photons introduced by a structured object. Furthermore, thanks to the “interaction-free” nature of this new technique, it is possible to reduce the number of photons required to produce a clear image of the object (which could be otherwise damaged by the photons) making this technique superior for probing light-sensitive materials and eventually biological tissues. If time allows, I will discuss some follow-up works involving partial measurements and remote erasure/completion of images. The latter techniques can help to suppress various types of noise during the imaging process.

•Mar 5, 2019•0 citations
The theory of partial coherence has a long and storied history in classical statistical optics. The vast majority of this work addresses fields that are statistically stationary in time, hence their complex envelopes only have phase-insensitive correlations. The quantum optics of squeezed-state generation, however, depends on nonlinear interactions producing baseband field operators with phase-insensitive and phase-sensitive correlations. Utilizing quantum light to enhance imaging has been a topic of considerable current interest, much of it involving biphotons, i.e., streams of entangled-photon pairs. Biphotons have been employed for quantum versions of optical coherence tomography, ghost imaging, holography, and lithography. However, their seemingly quantum features have been mimicked with classical-state light, questioning wherein lies the classical-quantum boundary. We have shown, for the case of Gaussian-state light, that this boundary is intimately connected to the theory of phase-sensitive partial coherence. Here we present that theory, contrasting it with the familiar case of phase-insensitive partial coherence, and use it to elucidate the classical-quantum boundary of ghost imaging. We show, both theoretically and experimentally, that classical phase-sensitive light produces ghost images most closely mimicking those obtained with biphotons, and we derive the spatial resolution, image contrast, and signal-to-noise ratio of a standoff-sensing ghost imager, taking into account target-induced speckle.
The theory of ghost imaging is developed in a Gaussian-state framework that both encompasses prior work---on thermal-state and biphoton-state imagers---and provides a complete understanding of the boundary between classical and quantum behavior in such systems. The core of this analysis is the expression derived for the photocurrent-correlation image obtained using a general Gaussian-state source. This image is expressed in terms of the phase-insensitive and phase-sensitive cross correlations between the two detected fields, plus a background. Because any pair of cross correlations is obtainable with classical Gaussian states, the image does not carry a quantum signature per se. However, if the image characteristics of classical and nonclassical Gaussian-state sources with identical autocorrelation functions are compared, the nonclassical source provides resolution improvement in its near field and field-of-view improvement in its far field.
In this letter, we use quantum description and the Gaussian state to study reflective ghost imaging with two classical sources, and to provide their expressions.We find that the reflective ghost imaging of a roughsurfaced object, using Gaussian-state phase-insensitive or classically correlated phase-sensitive light, can be expressed in terms of the phase-insensitive or phase-sensitive cross-correlations between the two detected fields, including a background term.Moreover, reflective ghost imaging with two classical Gaussian-state lights is shown to have similar features as spatial resolution and field of view.
In this letter,we use quantum description and the Gaussian state to study reflective ghost imaging with two classical sources,and to provide their expressions.We find that the reflective ghost imaging of a roughsurfaced object,using Gaussian-state phase-insensitive or classically correlated phase-sensitive light,can be expressed in terms of the phase-insensitive or phase-sensitive cross-correlations between the two detected fields,including a background term.Moreover,reflective ghost imaging with two classical Gaussian-state lights is shown to have similar features as spatial resolution and field of view.
We provide a unified treatment of classical and quantum Gaussian-state sources that unambiguously identifies which features of ghost imaging are strictly quantum mechanical. We show that ghost-image formation is fundamentally classical, with the image being expressible in terms of the phase-insensitive and phase-sensitive cross correlations between the detected fields. We then consider ghost-imaging scenarios with either phase-insensitive or phase-sensitive sources, where the former are always classical but the latter may be classical or quantum mechanical. We show that if their auto-correlations are identical, then a quantum source provides resolution improvement in its near-field and field-of-view improvement in its far field when compared to a classical source.
The signal-to-noise ratios (SNRs) of three Gaussian-state ghost-imaging configurations---distinguished by the nature of their light sources---are derived. Two use classical-state light, specifically a joint signal-reference field state that has either the maximum phase-insensitive or the maximum phase-sensitive cross correlation consistent with having a proper PPP representation. The third uses nonclassical light, in particular an entangled signal-reference field state with the maximum phase-sensitive cross correlation permitted by quantum mechanics. Analytic SNR expressions are developed for the near-field and far-field regimes, within which simple asymptotic approximations are presented for low-brightness and high-brightness sources. A high-brightness thermal-state (classical phase-insensitive state) source will typically achieve a higher SNR than a biphoton-state (low-brightness, low-flux limit of the entangled-state) source, when all other system parameters are equal for the two systems. With high efficiency photon-number-resolving detectors, a low-brightness, high-flux entangled-state source may achieve a higher SNR than that obtained with a high-brightness thermal-state source.
Correlated light (either classical or quantum) can be employed in various ways to improve resolution and measurement sensitivity. In an “interaction-free” measurement, a single photon can be used to reveal the presence of an object placed within one arm of an interferometer without being absorbed by it. This method has previously been applied to imaging. With a technique known as “ghost imaging”, entangled photon pairs are used for detecting an opaque object with significantly improved signal-to-noise ratio while preventing over-illumination. Here, we integrate these two methods to obtain a new imaging technique which we term “interaction-free ghost-imaging” that possesses the benefits of both techniques. While improving the image quality of conventional ghost-imaging, this new technique is also sensitive to phase and polarization changes in the photons introduced by a structured object. Furthermore, thanks to the “interaction-free” nature of this new technique, it is possible to reduce the number of photons required to produce a clear image of the object (which could be otherwise damaged by the photons) making this technique superior for probing light-sensitive materials and eventually biological tissues. If time allows, I will discuss some follow-up works involving partial measurements and remote erasure/completion of images. The latter techniques can help to suppress various types of noise during the imaging process.