Determination of hyperfine splittings and Landé gJ factors of 5s2S1/2 and 5p2P1/2,3/2 states of Cd+111,113 for microwave frequency standards

J. Z. Han, R. Si, H. R. Qin, N. C. Xin, Yong Chen, S. N. Miao, C. Y. Chen, Jianwei Zhang, L. J. Wang

Published Jul 27, 2022• 6 citations
arXivHTMLPDF

Abstract

Regarding microwave frequency standards based on trapped ions, we report on the determination of the hyperfine splittings and the Land\'e ${g}_{J}$ factors of $^{111,113}\mathrm{Cd}^{+}$. The hyperfine splittings and Land\'e ${g}_{J}$ factors of the $5s{\phantom{\rule{0.16em}{0ex}}}^{2}{S}_{1/2}$ and $5p{\phantom{\rule{0.16em}{0ex}}}^{2}{P}_{1/2,3/2}$ states of $^{111,113}\mathrm{Cd}^{+}$ are calculated using the multiconfiguration Dirac-Hartree-Fock scheme. Furthermore, the hyperfine splittings of the $5p{\phantom{\rule{0.16em}{0ex}}}^{2}{P}_{3/2}$ state of $^{111,113}\mathrm{Cd}^{+}$ are derived based on the laser-induced fluorescence spectroscopy. The ${\mathrm{Cd}}^{+}$ ions are confined in a linear Paul trap and sympathetically cooled by laser-cooled ${\mathrm{Ca}}^{+}$ ions. The calculated values and the derived values are cross-checked, thereby guaranteeing the reliability of our results. The results provided in this paper can improve the signal-to-noise ratio of the clock transition and the accuracy of the second-order Zeeman shift correction, thus further improving the stability and accuracy of the microwave frequency standards based on trapped $^{111,113}\mathrm{Cd}^{+}$ ions.

DOI
10.1103/physreva.106.012821

Related papers

Determination of the Landé g J factor and Zeeman coefficients in ground-state 171 Yb + and their applications to quantum frequency standards

J. Z. Han, Benquan Lu, Yanmei Yu +5 more

We report the determination of the Land\'e ${g}_{J}$ factor and Zeeman coefficients for the ground-state of ${}^{171}{\mathrm{Yb}}^{+}$, relevant to microwave quantum frequency standards (QFSs). The ${g}_{J}$ factor is obtained by using two independent methods, the multiconfiguration Dirac-Hartree-Fock and multireference configuration-interaction methods, yielding a consistent value of $2.002\phantom{\rule{0.16em}{0ex}}615(70)$. The first- and second-order Zeeman coefficients are determined as $14\phantom{\rule{0.16em}{0ex}}010.78(49)\phantom{\rule{4pt}{0ex}}\mathrm{Hz}/\textmu{}\mathrm{T}$ and $31.0869(22)\phantom{\rule{4pt}{0ex}}\mathrm{mHz}/\textmu{}{\mathrm{T}}^{2}$, respectively, based on the calculated ${g}_{J}$ factor. These coefficients enable reduced magnetic-field-induced uncertainties, improving the accuracy of the ${}^{171}{\mathrm{Yb}}^{+}$ microwave QFSs. The results reported in this work also offer potential for improved constraints on variations in fundamental constants through frequency comparisons and advancing trapped-ion quantum computers based on the ground-state hyperfine splitting of ${}^{171}{\mathrm{Yb}}^{+}$.

Physical Review A•Jan 17, 2025•3 citations

Determination of Landé $g_J$ factor and Zeeman coefficients in ground-state $^{171}$Yb$^+$ and their applications to quantum frequency standards

Han, Jize, Benquan Lu, Yanmei Yu +5 more

We report the determination of the Landé $g_J$ factor and Zeeman coefficients for the ground-state of $^{171}$Yb$^+$, relevant to microwave quantum frequency standards (QFSs). The $g_J$ factor is obtained by using two independent methods: multiconfiguration Dirac-Hartree-Fock and multireference configuration interaction, yielding a consistent value of 2.002615(70). The first- and second-order Zeeman coefficients are determined as 14,010.78(49) Hz/$μ$T and 31.0869(22) mHz/$μ$T$^2$, respectively, based on the calculated $g_J$ factor. These coefficients enable reduced magnetic-field-induced uncertainties, improving the accuracy of the $^{171}$Yb$^+$ microwave QFSs. The results reported in this work also offer potential for improved constraints on variations in fundamental constants through frequency comparisons, and advancing trapped-ion quantum computers based on the ground-state hyperfine splitting of $^{171}$Yb$^+$.

arXiv:2501.09973•Jan 17, 2025•0 citations

Precision Determination of the Ground-State Hyperfine Splitting in a 113Cd+ Microwave Clock

S. N. Miao, Y. H. Zheng, Yiting Chen +3 more

As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance$^{113}\text{Cd}^{+}$microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of$4.2\times 10^{-13}/\sqrt{\tau}$and a relative frequency uncertainty of$1.8\times 10^{-14}$, improving nearly three orders of magnitude compared to the result from JPL. The ground-state hyperfine splitting of$^{113}\text{Cd}^{+}$was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using$^{40}\text{Ca}^{+}$as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to$3.48\times 10^{-13}/\sqrt{\tau}$.

European Frequency and Time Forum•Jun 25, 2024•1 citation

Radio-frequency-spectroscopy measurement of the Landé gJ factor of the 5D5/2 state of Ba + with a single trapped ion

Matthew Hoffman, Thomas W. Noel, Carolyn Auchter +4 more

We report an improved measurement of the Land\'e ${g}_{J}$ factor of the $5{D}_{5/2}$ state of singly ionized barium. Measurements were performed on single Doppler-cooled ${}^{138}$Ba${}^{+}$ ions in linear Paul traps using two similar, independent apparatuses. Transitions between Zeeman sublevels of the $6{S}_{1/2}$ and $5{D}_{5/2}$ states were driven with two independent, stabilized radio-frequency synthesizers using a dedicated electrode within each ion trap chamber. State detection within each Zeeman manifold was achieved with a frequency-stabilized fiber laser operating at 1.76 $\ensuremath{\mu}$m. By calculating the ratio of the two Zeeman splittings, and using the measured Land\'e ${g}_{J}$ factor of the $6{S}_{1/2}$ state, we find a value of 1.200 372$({4}_{\mathrm{stat}})({7}_{\mathrm{sys}})$ for ${g}_{{D}_{5/2}}$.

arXiv:1306.3518•Physical Review A•Aug 28, 2013•14 citations

High-accuracy measurement of the ^113Cd^+ ground-state hyperfine splitting at the milli-Hertz level

Shiguang Wang, Jianwei Zhang, K. Miao +2 more

We have developed a microwave frequency standard based on the 15.2 GHz ground-stated hyperfine transition of (113)C(+) ions. Using a laser-cooled ion cloud trapped in a linear quadrupole Paul trap, the clock transition frequency is measured to be 15 199 862 855.0125(87) Hz, with an accuracy at the 10(-13) level. The main errors are from the microwave frequency reference used in the experiment. The precision is improved by nearly two orders of magnitude than that reported before.

Optics Express•May 14, 2013•19 citations

Observation of the hyperfine structure of the 2S1/2−2D5/2 transition in 87Sr+

G. P. Barwood, K. Gao, Patrick Robert Gill +2 more

The hyperfine structure of the ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ quadrupole transition at 674 nm in ${}^{87}{\mathrm{Sr}}^{+}$ has been observed. The ion was confined in a Paul trap and cooled using laser radiation at 422 and 1092 nm. The quadrupole transition was observed by monitoring quantum jumps in the 422-nm fluorescence. The odd isotope of strontium has ``clock'' transitions independent of the first-order Zeeman shift and the ${}^{2}{D}_{5/2}$ state hyperfine structure constants have been determined as ${A}_{{D}_{5/2}}=2.1743(14)\mathrm{MHz}$ and ${B}_{{D}_{5/2}}=49.11(6)\mathrm{MHz}.$ Standard uncertainties have been added in parentheses. These values allow the second-order Zeeman shifts to be calculated. The ${}^{88}{\mathrm{Sr}}^{+}{\ensuremath{-}}^{87}{\mathrm{Sr}}^{+}$ isotope shift for the 674-nm quadrupole transition has been measured to be 247.99(4) MHz.

Physical Review A•Jan 8, 2003•44 citations
Regarding microwave frequency standards based on trapped ions, we report on the determination of the hyperfine splittings and the Land'e gJ{g}_{J}gJ​ factors of 111,113Cd+^{111,113}\mathrm{Cd}^{+}111,113Cd+. The hyperfine splittings and Land'e gJ{g}_{J}gJ​ factors of the 5s2S1/25s{\phantom{\rule{0.16em}{0ex}}}^{2}{S}_{1/2}5s2S1/2​ and 5p2P1/2,3/25p{\phantom{\rule{0.16em}{0ex}}}^{2}{P}_{1/2,3/2}5p2P1/2,3/2​ states of 111,113Cd+^{111,113}\mathrm{Cd}^{+}111,113Cd+ are calculated using the multiconfiguration Dirac-Hartree-Fock scheme. Furthermore, the hyperfine splittings of the 5p2P3/25p{\phantom{\rule{0.16em}{0ex}}}^{2}{P}_{3/2}5p2P3/2​ state of 111,113Cd+^{111,113}\mathrm{Cd}^{+}111,113Cd+ are derived based on the laser-induced fluorescence spectroscopy. The Cd+{\mathrm{Cd}}^{+}Cd+ ions are confined in a linear Paul trap and sympathetically cooled by laser-cooled Ca+{\mathrm{Ca}}^{+}Ca+ ions. The calculated values and the derived values are cross-checked, thereby guaranteeing the reliability of our results. The results provided in this paper can improve the signal-to-noise ratio of the clock transition and the accuracy of the second-order Zeeman shift correction, thus further improving the stability and accuracy of the microwave frequency standards based on trapped 111,113Cd+^{111,113}\mathrm{Cd}^{+}111,113Cd+ ions.
We report the determination of the Land\'e gJ{g}_{J}gJ​ factor and Zeeman coefficients for the ground-state of 171Yb+{}^{171}{\mathrm{Yb}}^{+}171Yb+, relevant to microwave quantum frequency standards (QFSs). The gJ{g}_{J}gJ​ factor is obtained by using two independent methods, the multiconfiguration Dirac-Hartree-Fock and multireference configuration-interaction methods, yielding a consistent value of 2.002615(70)2.002\phantom{\rule{0.16em}{0ex}}615(70)2.002615(70). The first- and second-order Zeeman coefficients are determined as $14\phantom{\rule{0.16em}{0ex}}010.78(49)\phantom{\rule{4pt}{0ex}}\mathrm{Hz}/\textmu{}\mathrm{T}$ and $31.0869(22)\phantom{\rule{4pt}{0ex}}\mathrm{mHz}/\textmu{}{\mathrm{T}}^{2}$, respectively, based on the calculated gJ{g}_{J}gJ​ factor. These coefficients enable reduced magnetic-field-induced uncertainties, improving the accuracy of the 171Yb+{}^{171}{\mathrm{Yb}}^{+}171Yb+ microwave QFSs. The results reported in this work also offer potential for improved constraints on variations in fundamental constants through frequency comparisons and advancing trapped-ion quantum computers based on the ground-state hyperfine splitting of 171Yb+{}^{171}{\mathrm{Yb}}^{+}171Yb+.
Determination of Landé gJg_JgJ​ factor and Zeeman coefficients in ground-state 171^{171}171Yb+^++ and their applications to quantum frequency standards
We report the determination of the Landé gJg_JgJ​ factor and Zeeman coefficients for the ground-state of 171^{171}171Yb+^++, relevant to microwave quantum frequency standards (QFSs). The gJg_JgJ​ factor is obtained by using two independent methods: multiconfiguration Dirac-Hartree-Fock and multireference configuration interaction, yielding a consistent value of 2.002615(70). The first- and second-order Zeeman coefficients are determined as 14,010.78(49) Hz/μμμT and 31.0869(22) mHz/μμμT2^22, respectively, based on the calculated gJg_JgJ​ factor. These coefficients enable reduced magnetic-field-induced uncertainties, improving the accuracy of the 171^{171}171Yb+^++ microwave QFSs. The results reported in this work also offer potential for improved constraints on variations in fundamental constants through frequency comparisons, and advancing trapped-ion quantum computers based on the ground-state hyperfine splitting of 171^{171}171Yb+^++.
As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance113Cd+^{113}\text{Cd}^{+}113Cd+microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of4.2×10−13/τ4.2\times 10^{-13}/\sqrt{\tau}4.2×10−13/τ​and a relative frequency uncertainty of1.8×10−141.8\times 10^{-14}1.8×10−14, improving nearly three orders of magnitude compared to the result from JPL. The ground-state hyperfine splitting of113Cd+^{113}\text{Cd}^{+}113Cd+was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using40Ca+^{40}\text{Ca}^{+}40Ca+as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to3.48×10−13/τ3.48\times 10^{-13}/\sqrt{\tau}3.48×10−13/τ​.
We report an improved measurement of the Land\'e gJ{g}_{J}gJ​ factor of the 5D5/25{D}_{5/2}5D5/2​ state of singly ionized barium. Measurements were performed on single Doppler-cooled 138{}^{138}138Ba+{}^{+}+ ions in linear Paul traps using two similar, independent apparatuses. Transitions between Zeeman sublevels of the 6S1/26{S}_{1/2}6S1/2​ and 5D5/25{D}_{5/2}5D5/2​ states were driven with two independent, stabilized radio-frequency synthesizers using a dedicated electrode within each ion trap chamber. State detection within each Zeeman manifold was achieved with a frequency-stabilized fiber laser operating at 1.76 $\ensuremath{\mu}$m. By calculating the ratio of the two Zeeman splittings, and using the measured Land\'e gJ{g}_{J}gJ​ factor of the 6S1/26{S}_{1/2}6S1/2​ state, we find a value of 1.200 372(4stat)(7sys)({4}_{\mathrm{stat}})({7}_{\mathrm{sys}})(4stat​)(7sys​) for gD5/2{g}_{{D}_{5/2}}gD5/2​​.
The hyperfine structure of the ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ quadrupole transition at 674 nm in 87Sr+{}^{87}{\mathrm{Sr}}^{+}87Sr+ has been observed. The ion was confined in a Paul trap and cooled using laser radiation at 422 and 1092 nm. The quadrupole transition was observed by monitoring quantum jumps in the 422-nm fluorescence. The odd isotope of strontium has ``clock'' transitions independent of the first-order Zeeman shift and the 2D5/2{}^{2}{D}_{5/2}2D5/2​ state hyperfine structure constants have been determined as AD5/2=2.1743(14)MHz{A}_{{D}_{5/2}}=2.1743(14)\mathrm{MHz}AD5/2​​=2.1743(14)MHz and BD5/2=49.11(6)MHz.{B}_{{D}_{5/2}}=49.11(6)\mathrm{MHz}.BD5/2​​=49.11(6)MHz. Standard uncertainties have been added in parentheses. These values allow the second-order Zeeman shifts to be calculated. The ${}^{88}{\mathrm{Sr}}^{+}{\ensuremath{-}}^{87}{\mathrm{Sr}}^{+}$ isotope shift for the 674-nm quadrupole transition has been measured to be 247.99(4) MHz.