Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2109.12237

High precision differential clock comparisons with a multiplexed optical lattice clock

Xin Zheng, Jonathan Dolde, Varun Lochab, Brett Merriman, Li, Haoran, Shimon Kolkowitz

Published Sep 24, 2021• 5 citations
arXivHTMLPDF

Abstract

Rapid progress in the precision and accuracy of optical atomic clocks over the last decade has advanced the frontiers of timekeeping, metrology, and quantum science. However, the stabilities of most optical clocks remain limited by the local oscillator rather than the atoms themselves, leaving room for further progress. Here we implement a "multiplexed" one-dimensional optical lattice clock, in which spatially-resolved, movable ensembles of ultra-cold strontium atoms are trapped in the same optical lattice, interrogated simultaneously by a shared clock laser, and read-out in parallel. By performing synchronized Ramsey interrogations of ensemble pairs we observe atom-atom coherence times up to 26 seconds, a 270-fold improvement over the atom-laser coherence time, demonstrate a relative stability of $9.7(4)\times10^{-18}/\sqrtτ$ (where $τ$ is the averaging time in seconds), and reach a fractional uncertainty of $8.9(3)\times 10^{-20}$ after 3.3 hours of averaging. These results demonstrate that applications requiring ultra-high-precision comparisons between optical atomic clocks need not be limited by the stability of the local oscillator. With multiple ensemble pairs, we realize a miniaturized clock network consisting of 6 atom ensembles, resulting in 15 unique pairwise clock comparisons with relative stabilities below $3\times10^{-17}/\sqrtτ$. Finally, we demonstrate the capability to simultaneously load spatially-resolved, heterogeneous ensemble pairs of all four stable isotopes of strontium in a lattice. The unique capabilities offered by this platform pave the way for future studies of precision isotope shift measurements, spatially resolved characterization of limiting clock systematics, development of clock-based gravitational wave and dark matter detectors, and novel tests of relativity including measurements of the gravitational redshift at sub-centimeter scales.

DOI
10.48550/arxiv.2109.12237

Related papers

A Multiplexed Strontium Optical Lattice Clock

Jonathan Dolde

Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.

•May 1, 2026•0 citations

Reducing the Instability of an Optical Lattice Clock Using Multiple Atomic Ensembles

Xin Zheng, Jonathan Dolde, Shimon Kolkowitz

The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening the coherent interrogation times, and introducing entanglement to push beyond the standard quantum limit. In this work, we experimentally demonstrate an alternative approach to reducing clock instability using a phase estimation approach based on individually controlled atomic ensembles in a strontium (Sr) optical lattice clock. We first demonstrate joint Ramsey interrogation of two spatially resolved atom ensembles that are out of phase with respect to each other, which we call “quadrature Ramsey spectroscopy,” resulting in a factor of 1.36(5) reduction in absolute clock instability as measured with interleaved self-comparisons. We then leverage the rich hyperfine structure of Sr87 to realize independent coherent control over multiple ensembles with only global laser addressing. Finally, we utilize this independent control over four atom ensembles to implement a form of phase estimation, achieving a factor of greater than 3 enhancement in coherent interrogation time and a factor of 2.08(6) reduction in instability over an otherwise identical single-ensemble clock with the same local oscillator and the same number of atoms. We expect that multiensemble protocols similar to those demonstrated here will result in reduction in the instability of any optical lattice clock with an interrogation time limited by the local oscillator. Published by the American Physical Society 2024

arXiv:2305.12315•Physical Review X•Jan 23, 2024•17 citations

Optical coherence between atomic species at the second scale: improved clock comparisons via differential spectroscopy

May E. Kim, William F. McGrew, Nicholas V. Nardelli +9 more

Comparisons of high-accuracy optical atomic clocks \cite{Ludlow2015} are essential for precision tests of fundamental physics \cite{Safronova2018}, relativistic geodesy \cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \cite{Schioppo2017} Yb optical lattice clock with an Al$^+$ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.

arXiv:2109.09540•Sep 20, 2021•3 citations

Comparison of Two Independent Sr Optical Clocks with 1 × 10 − 17 Stability at 10 3 s

Travis Nicholson, Michael J. Martin, Jason Williams +5 more

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two $^{87}\mathrm{Sr}$ lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.

arXiv:1210.0064•Physical Review Letters•Dec 5, 2012•204 citations

Decoherence of Atomic Ensembles in Optical Lattice Clocks by Gravity

Akio Kawasaki

Optical lattice clocks can now resolve the height difference below 1 mm within an atomic ensemble by means of gravitational redshift with integration over sufficient amount of time. Further improvement in the stability enables the clocks to resolve the height difference of subsystems within an atomic ensemble that is conventionally interrogated as a single coherent spin state in a single Ramsey sequence, resulting in the dephasing of the coherent spin state. This effect is observable with a clock of a stability of $\lesssim 10^{-21}$ by introducing a single-layer-resolved imaging system for a three-dimensional optical lattice, and limits the 1 s stability of the clock around $10^{-19}$ for an atomic ensemble distributing symmetrically for the three axes, which is also a signal of the decoherence. With atoms in an entangled state, this can be the first observation of the decoherence of a quantum state by a gravitational effect, and the suppression of other systematic shifts to observe this decoherence seems feasible.

arXiv:2107.02405•Journal of the Physical Society of Japan•Feb 2, 2022•1 citation

Clock Precision beyond the Standard Quantum Limit at 10 − 18 Level

Yutong Yang, Maya Miklos, Yee Ming Tso +3 more

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1×10^{-18} for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

arXiv:2505.04538•Physical Review Letters•Nov 7, 2025•12 citations
Rapid progress in the precision and accuracy of optical atomic clocks over the last decade has advanced the frontiers of timekeeping, metrology, and quantum science. However, the stabilities of most optical clocks remain limited by the local oscillator rather than the atoms themselves, leaving room for further progress. Here we implement a "multiplexed" one-dimensional optical lattice clock, in which spatially-resolved, movable ensembles of ultra-cold strontium atoms are trapped in the same optical lattice, interrogated simultaneously by a shared clock laser, and read-out in parallel. By performing synchronized Ramsey interrogations of ensemble pairs we observe atom-atom coherence times up to 26 seconds, a 270-fold improvement over the atom-laser coherence time, demonstrate a relative stability of 9.7(4)×10−18/τ9.7(4)\times10^{-18}/\sqrtτ9.7(4)×10−18/τ​ (where τττ is the averaging time in seconds), and reach a fractional uncertainty of 8.9(3)×10−208.9(3)\times 10^{-20}8.9(3)×10−20 after 3.3 hours of averaging. These results demonstrate that applications requiring ultra-high-precision comparisons between optical atomic clocks need not be limited by the stability of the local oscillator. With multiple ensemble pairs, we realize a miniaturized clock network consisting of 6 atom ensembles, resulting in 15 unique pairwise clock comparisons with relative stabilities below 3×10−17/τ3\times10^{-17}/\sqrtτ3×10−17/τ​. Finally, we demonstrate the capability to simultaneously load spatially-resolved, heterogeneous ensemble pairs of all four stable isotopes of strontium in a lattice. The unique capabilities offered by this platform pave the way for future studies of precision isotope shift measurements, spatially resolved characterization of limiting clock systematics, development of clock-based gravitational wave and dark matter detectors, and novel tests of relativity including measurements of the gravitational redshift at sub-centimeter scales.
Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.
The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening the coherent interrogation times, and introducing entanglement to push beyond the standard quantum limit. In this work, we experimentally demonstrate an alternative approach to reducing clock instability using a phase estimation approach based on individually controlled atomic ensembles in a strontium (Sr) optical lattice clock. We first demonstrate joint Ramsey interrogation of two spatially resolved atom ensembles that are out of phase with respect to each other, which we call “quadrature Ramsey spectroscopy,” resulting in a factor of 1.36(5) reduction in absolute clock instability as measured with interleaved self-comparisons. We then leverage the rich hyperfine structure of Sr87 to realize independent coherent control over multiple ensembles with only global laser addressing. Finally, we utilize this independent control over four atom ensembles to implement a form of phase estimation, achieving a factor of greater than 3 enhancement in coherent interrogation time and a factor of 2.08(6) reduction in instability over an otherwise identical single-ensemble clock with the same local oscillator and the same number of atoms. We expect that multiensemble protocols similar to those demonstrated here will result in reduction in the instability of any optical lattice clock with an interrogation time limited by the local oscillator. Published by the American Physical Society 2024
Comparisons of high-accuracy optical atomic clocks \cite{Ludlow2015} are essential for precision tests of fundamental physics \cite{Safronova2018}, relativistic geodesy \cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \cite{Schioppo2017} Yb optical lattice clock with an Al+^++ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr^{87}\mathrm{Sr}87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.
Optical lattice clocks can now resolve the height difference below 1 mm within an atomic ensemble by means of gravitational redshift with integration over sufficient amount of time. Further improvement in the stability enables the clocks to resolve the height difference of subsystems within an atomic ensemble that is conventionally interrogated as a single coherent spin state in a single Ramsey sequence, resulting in the dephasing of the coherent spin state. This effect is observable with a clock of a stability of ≲10−21\lesssim 10^{-21}≲10−21 by introducing a single-layer-resolved imaging system for a three-dimensional optical lattice, and limits the 1 s stability of the clock around 10−1910^{-19}10−19 for an atomic ensemble distributing symmetrically for the three axes, which is also a signal of the decoherence. With atoms in an entangled state, this can be the first observation of the decoherence of a quantum state by a gravitational effect, and the suppression of other systematic shifts to observe this decoherence seems feasible.
Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1×10^{-18} for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.