arXiv:2305.12315 · Physical Review X

Reducing the Instability of an Optical Lattice Clock Using Multiple Atomic Ensembles

Xin Zheng, Jonathan Dolde, Shimon Kolkowitz

Published Jan 23, 2024• 17 citations
arXivHTMLPDF

Abstract

The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening the coherent interrogation times, and introducing entanglement to push beyond the standard quantum limit. In this work, we experimentally demonstrate an alternative approach to reducing clock instability using a phase estimation approach based on individually controlled atomic ensembles in a strontium (Sr) optical lattice clock. We first demonstrate joint Ramsey interrogation of two spatially resolved atom ensembles that are out of phase with respect to each other, which we call “quadrature Ramsey spectroscopy,” resulting in a factor of 1.36(5) reduction in absolute clock instability as measured with interleaved self-comparisons. We then leverage the rich hyperfine structure of Sr87 to realize independent coherent control over multiple ensembles with only global laser addressing. Finally, we utilize this independent control over four atom ensembles to implement a form of phase estimation, achieving a factor of greater than 3 enhancement in coherent interrogation time and a factor of 2.08(6) reduction in instability over an otherwise identical single-ensemble clock with the same local oscillator and the same number of atoms. We expect that multiensemble protocols similar to those demonstrated here will result in reduction in the instability of any optical lattice clock with an interrogation time limited by the local oscillator. Published by the American Physical Society 2024

DOI
10.1103/physrevx.14.011006

Related papers

High precision differential clock comparisons with a multiplexed optical lattice clock

Xin Zheng, Jonathan Dolde, Varun Lochab +3 more

Rapid progress in the precision and accuracy of optical atomic clocks over the last decade has advanced the frontiers of timekeeping, metrology, and quantum science. However, the stabilities of most optical clocks remain limited by the local oscillator rather than the atoms themselves, leaving room for further progress. Here we implement a "multiplexed" one-dimensional optical lattice clock, in which spatially-resolved, movable ensembles of ultra-cold strontium atoms are trapped in the same optical lattice, interrogated simultaneously by a shared clock laser, and read-out in parallel. By performing synchronized Ramsey interrogations of ensemble pairs we observe atom-atom coherence times up to 26 seconds, a 270-fold improvement over the atom-laser coherence time, demonstrate a relative stability of $9.7(4)\times10^{-18}/\sqrtτ$ (where $τ$ is the averaging time in seconds), and reach a fractional uncertainty of $8.9(3)\times 10^{-20}$ after 3.3 hours of averaging. These results demonstrate that applications requiring ultra-high-precision comparisons between optical atomic clocks need not be limited by the stability of the local oscillator. With multiple ensemble pairs, we realize a miniaturized clock network consisting of 6 atom ensembles, resulting in 15 unique pairwise clock comparisons with relative stabilities below $3\times10^{-17}/\sqrtτ$. Finally, we demonstrate the capability to simultaneously load spatially-resolved, heterogeneous ensemble pairs of all four stable isotopes of strontium in a lattice. The unique capabilities offered by this platform pave the way for future studies of precision isotope shift measurements, spatially resolved characterization of limiting clock systematics, development of clock-based gravitational wave and dark matter detectors, and novel tests of relativity including measurements of the gravitational redshift at sub-centimeter scales.

arXiv:2109.12237•Sep 24, 2021•5 citations

Enhancing Optical Lattice Clock Coherence Times with Erasure Conversion

Shuo Ma, Jonathan Dolde, Xin Zheng +6 more

Increasing coherent interrogation times is central to advancing the precision of optical clocks. Synchronous differential optical clock comparisons have now demonstrated atomic coherence times that far exceed the coherence time of the clock laser. While atom coherence times are then primarily limited by errors induced by lattice Raman scattering, excited clock state radiative decay, and broadening from two-body collisions, many of these errors take the atoms out of the clock transition subspace, and can therefore be converted into “erasure” errors if the appropriate readout scheme is employed. Here we experimentally demonstrate a hyperfine-resolved readout technique for 87 Sr optical lattice clocks that mitigates decoherence from Raman scattering induced by the lattice as well as radiative decay. By employing hyperfine-resolved readout in synchronous differential comparisons between 87 Sr ensembles with both Ramsey and spin-echo spectroscopy sequences, we achieve enhanced atomic coherence times exceeding 100 and 150 s, respectively, enabling longer coherent measurements without a reduction in performance. We anticipate that this hyperfine-resolved readout technique will benefit applications of state-of-the-art optical lattice clock comparisons in which the coherence times are constrained by Raman scattering or radiative decay.

arXiv:2505.06437•PRX Quantum•Nov 19, 2025•2 citations

A Multiplexed Strontium Optical Lattice Clock

Jonathan Dolde

Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.

•May 1, 2026•0 citations

Improved absolute clock stability by the joint interrogation of two atomic ensembles

Weidong Li, Shuyuan Wu, Augusto Smerzi +1 more

Improving the clock stability is of fundamental importance for the development of quantum-enhanced metrology. One of the main limitations arises from the randomly fluctuating local oscillator (LO) frequency, which introduces ``phase slips'' for long interrogation times and hence the failure of the frequency-feedback loop. Here we propose a strategy to improve the stability of atomic clocks by interrogating two atomic ensembles sharing the same LO. The two ensembles are prepared in coherent spin states pointing along orthogonal directions in the Bloch sphere. While standard Ramsey interrogation can only determine phases unambiguously in the interval $[\ensuremath{-}\ensuremath{\pi}/2,\ensuremath{\pi}/2]$, the joint interrogation allows for an extension to $[\ensuremath{-}\ensuremath{\pi},\ensuremath{\pi}]$, resulting in a relaxed restriction of the Ramsey time and improvement of absolute clock stability. Theoretical predictions are supported by ab initio numerical simulation for white and correlated LO noise. While our basic protocol uses uncorrelated atoms, we further extended it to include spin-squeezing and further improving the scaling of clock stability with the number of atoms. Our protocol can be readily tested in current state-of-the-art experiments.

arXiv:2104.14309•Physical Review A•May 19, 2022•8 citations

Dynamical decoupling of laser phase noise in compound atomic clocks

Sören Dörscher, Ali Al-Masoudi, Marcin Bober +4 more

Abstract The frequency stability of many optical atomic clocks is limited by the coherence of their local oscillator. Here, we present a measurement protocol that overcomes the laser coherence limit. It relies on engineered dynamical decoupling of laser phase noise and near-synchronous interrogation of two clocks. One clock coarsely tracks the laser phase using dynamical decoupling; the other refines this estimate using a high-resolution phase measurement. While the former needs to have a high signal-to-noise ratio, the latter clock may operate with any number of particles. The protocol effectively enables minute-long Ramsey interrogation for coherence times of few seconds as provided by the current best ultrastable laser systems. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment, where we interrogate for 0.5 s at a laser coherence time of 77 ms. Here, a single lattice clock is used to emulate synchronous interrogation of two separate clocks in the presence of artificial laser frequency noise. We discuss the frequency instability of a single-ion clock that would result from using the protocol for stabilisation, under these conditions and for minute-long interrogation, and find expected instabilities of σy(τ) = 8 × 10−16(τ/s)−1/2 and σy(τ) = 5 × 10−17(τ/s)−1/2, respectively.

Communications Physics•Oct 20, 2020•23 citations

Optical coherence between atomic species at the second scale: improved clock comparisons via differential spectroscopy

May E. Kim, William F. McGrew, Nicholas V. Nardelli +9 more

Comparisons of high-accuracy optical atomic clocks \cite{Ludlow2015} are essential for precision tests of fundamental physics \cite{Safronova2018}, relativistic geodesy \cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \cite{Schioppo2017} Yb optical lattice clock with an Al$^+$ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.

arXiv:2109.09540•Sep 20, 2021•3 citations
The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening the coherent interrogation times, and introducing entanglement to push beyond the standard quantum limit. In this work, we experimentally demonstrate an alternative approach to reducing clock instability using a phase estimation approach based on individually controlled atomic ensembles in a strontium (Sr) optical lattice clock. We first demonstrate joint Ramsey interrogation of two spatially resolved atom ensembles that are out of phase with respect to each other, which we call “quadrature Ramsey spectroscopy,” resulting in a factor of 1.36(5) reduction in absolute clock instability as measured with interleaved self-comparisons. We then leverage the rich hyperfine structure of Sr87 to realize independent coherent control over multiple ensembles with only global laser addressing. Finally, we utilize this independent control over four atom ensembles to implement a form of phase estimation, achieving a factor of greater than 3 enhancement in coherent interrogation time and a factor of 2.08(6) reduction in instability over an otherwise identical single-ensemble clock with the same local oscillator and the same number of atoms. We expect that multiensemble protocols similar to those demonstrated here will result in reduction in the instability of any optical lattice clock with an interrogation time limited by the local oscillator. Published by the American Physical Society 2024
Rapid progress in the precision and accuracy of optical atomic clocks over the last decade has advanced the frontiers of timekeeping, metrology, and quantum science. However, the stabilities of most optical clocks remain limited by the local oscillator rather than the atoms themselves, leaving room for further progress. Here we implement a "multiplexed" one-dimensional optical lattice clock, in which spatially-resolved, movable ensembles of ultra-cold strontium atoms are trapped in the same optical lattice, interrogated simultaneously by a shared clock laser, and read-out in parallel. By performing synchronized Ramsey interrogations of ensemble pairs we observe atom-atom coherence times up to 26 seconds, a 270-fold improvement over the atom-laser coherence time, demonstrate a relative stability of 9.7(4)×10−18/τ9.7(4)\times10^{-18}/\sqrtτ9.7(4)×10−18/τ​ (where τττ is the averaging time in seconds), and reach a fractional uncertainty of 8.9(3)×10−208.9(3)\times 10^{-20}8.9(3)×10−20 after 3.3 hours of averaging. These results demonstrate that applications requiring ultra-high-precision comparisons between optical atomic clocks need not be limited by the stability of the local oscillator. With multiple ensemble pairs, we realize a miniaturized clock network consisting of 6 atom ensembles, resulting in 15 unique pairwise clock comparisons with relative stabilities below 3×10−17/τ3\times10^{-17}/\sqrtτ3×10−17/τ​. Finally, we demonstrate the capability to simultaneously load spatially-resolved, heterogeneous ensemble pairs of all four stable isotopes of strontium in a lattice. The unique capabilities offered by this platform pave the way for future studies of precision isotope shift measurements, spatially resolved characterization of limiting clock systematics, development of clock-based gravitational wave and dark matter detectors, and novel tests of relativity including measurements of the gravitational redshift at sub-centimeter scales.
Increasing coherent interrogation times is central to advancing the precision of optical clocks. Synchronous differential optical clock comparisons have now demonstrated atomic coherence times that far exceed the coherence time of the clock laser. While atom coherence times are then primarily limited by errors induced by lattice Raman scattering, excited clock state radiative decay, and broadening from two-body collisions, many of these errors take the atoms out of the clock transition subspace, and can therefore be converted into “erasure” errors if the appropriate readout scheme is employed. Here we experimentally demonstrate a hyperfine-resolved readout technique for 87 Sr optical lattice clocks that mitigates decoherence from Raman scattering induced by the lattice as well as radiative decay. By employing hyperfine-resolved readout in synchronous differential comparisons between 87 Sr ensembles with both Ramsey and spin-echo spectroscopy sequences, we achieve enhanced atomic coherence times exceeding 100 and 150 s, respectively, enabling longer coherent measurements without a reduction in performance. We anticipate that this hyperfine-resolved readout technique will benefit applications of state-of-the-art optical lattice clock comparisons in which the coherence times are constrained by Raman scattering or radiative decay.
Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.
Improving the clock stability is of fundamental importance for the development of quantum-enhanced metrology. One of the main limitations arises from the randomly fluctuating local oscillator (LO) frequency, which introduces ``phase slips'' for long interrogation times and hence the failure of the frequency-feedback loop. Here we propose a strategy to improve the stability of atomic clocks by interrogating two atomic ensembles sharing the same LO. The two ensembles are prepared in coherent spin states pointing along orthogonal directions in the Bloch sphere. While standard Ramsey interrogation can only determine phases unambiguously in the interval $[\ensuremath{-}\ensuremath{\pi}/2,\ensuremath{\pi}/2]$, the joint interrogation allows for an extension to $[\ensuremath{-}\ensuremath{\pi},\ensuremath{\pi}]$, resulting in a relaxed restriction of the Ramsey time and improvement of absolute clock stability. Theoretical predictions are supported by ab initio numerical simulation for white and correlated LO noise. While our basic protocol uses uncorrelated atoms, we further extended it to include spin-squeezing and further improving the scaling of clock stability with the number of atoms. Our protocol can be readily tested in current state-of-the-art experiments.
Abstract The frequency stability of many optical atomic clocks is limited by the coherence of their local oscillator. Here, we present a measurement protocol that overcomes the laser coherence limit. It relies on engineered dynamical decoupling of laser phase noise and near-synchronous interrogation of two clocks. One clock coarsely tracks the laser phase using dynamical decoupling; the other refines this estimate using a high-resolution phase measurement. While the former needs to have a high signal-to-noise ratio, the latter clock may operate with any number of particles. The protocol effectively enables minute-long Ramsey interrogation for coherence times of few seconds as provided by the current best ultrastable laser systems. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment, where we interrogate for 0.5 s at a laser coherence time of 77 ms. Here, a single lattice clock is used to emulate synchronous interrogation of two separate clocks in the presence of artificial laser frequency noise. We discuss the frequency instability of a single-ion clock that would result from using the protocol for stabilisation, under these conditions and for minute-long interrogation, and find expected instabilities of σy(τ) = 8 × 10−16(τ/s)−1/2 and σy(τ) = 5 × 10−17(τ/s)−1/2, respectively.
Comparisons of high-accuracy optical atomic clocks \cite{Ludlow2015} are essential for precision tests of fundamental physics \cite{Safronova2018}, relativistic geodesy \cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \cite{Schioppo2017} Yb optical lattice clock with an Al+^++ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.