Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2007.02193 · Physical Review Letters

Lifetime-Limited Interrogation of Two Independent Al + 27 Clocks Using Correlation Spectroscopy

Ethan Clements, May E. Kim, Kaifeng Cui, Aaron M. Hankin, Samuel M. Brewer, Jose Valencia, Jwo-Sy Chen, Chin-Wen Chou, David R. Leibrandt, David B. Hume

Published Dec 9, 2020• 39 citations
arXivHTMLPDF

Abstract

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+}. By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12×10^{15} Hz. The observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s ^{3}P_{0} state lifetime and represents a measurement instability of (1.8±0.5)×10^{-16}/sqrt[τ/s] for averaging periods longer than the probe duration when dead time is negligible.

DOI
10.1103/physrevlett.125.243602

Related papers

Leveraging correlated laser noise to improve optical frequency comparisons

Ethan Clements, M. Bohman, May E. Kim +14 more

Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2022•0 citations

Dynamical decoupling of laser phase noise in compound atomic clocks

Sören Dörscher, Ali Al-Masoudi, Marcin Bober +4 more

Abstract The frequency stability of many optical atomic clocks is limited by the coherence of their local oscillator. Here, we present a measurement protocol that overcomes the laser coherence limit. It relies on engineered dynamical decoupling of laser phase noise and near-synchronous interrogation of two clocks. One clock coarsely tracks the laser phase using dynamical decoupling; the other refines this estimate using a high-resolution phase measurement. While the former needs to have a high signal-to-noise ratio, the latter clock may operate with any number of particles. The protocol effectively enables minute-long Ramsey interrogation for coherence times of few seconds as provided by the current best ultrastable laser systems. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment, where we interrogate for 0.5 s at a laser coherence time of 77 ms. Here, a single lattice clock is used to emulate synchronous interrogation of two separate clocks in the presence of artificial laser frequency noise. We discuss the frequency instability of a single-ion clock that would result from using the protocol for stabilisation, under these conditions and for minute-long interrogation, and find expected instabilities of σy(τ) = 8 × 10−16(τ/s)−1/2 and σy(τ) = 5 × 10−17(τ/s)−1/2, respectively.

Communications Physics•Oct 20, 2020•23 citations

Probing beyond the laser coherence time in optical clock comparisons

David B. Hume, David R. Leibrandt

We develop differential measurement protocols that circumvent the laser noise limit in the stability of optical clock comparisons by synchronous probing of two clocks using phase-locked local oscillators. This allows for probe times longer than the laser coherence time, avoids the Dick effect, and supports Heisenberg-limited measurement precision. We present protocols for such frequency comparisons and develop numerical simulations of the protocols with realistic noise sources. These methods provide a route to reduce frequency ratio measurement durations by more than an order of magnitude.

arXiv:1508.05129•Physical Review A•Mar 30, 2016•43 citations

Spin squeezing can only improve clocks with small atom number

Marius Schulte, Christian Lisdat, Piet O. Schmidt +2 more

We show that the stability of an optical atomic clock can only be improved by spin squeezed states for ensembles below a critical particle number. This limitation results from a trade-off between measurement noise and instabilities due to limited laser coherence. Our results apply to the case of cyclic Ramsey interrogations on a single atomic ensemble with dead time between each measurement. The combination of analytical models for projection noise, dead time noise (Dick effect) and laser phase noise allows quantitative predictions of the critical particle number and the optimal clock stability for a given dead time and laser noise. Our analytical predictions are confirmed by numerical simulations of the closed servo loop of an optical atomic clock.

•Nov 3, 2019•0 citations

Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level

Xiao-Yong Liu, Peng Liu, Jie Li +20 more

Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.

Physical Review Letters•Nov 26, 2025•9 citations

Frequency comparison of optical lattice clocks

Masao Takamoto, T. Takano, Hidetoshi Katori

We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 8, 2011•0 citations
Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+}. By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12×10^{15} Hz. The observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s ^{3}P_{0} state lifetime and represents a measurement instability of (1.8±0.5)×10^{-16}/sqrt[τ/s] for averaging periods longer than the probe duration when dead time is negligible.
Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.
Abstract The frequency stability of many optical atomic clocks is limited by the coherence of their local oscillator. Here, we present a measurement protocol that overcomes the laser coherence limit. It relies on engineered dynamical decoupling of laser phase noise and near-synchronous interrogation of two clocks. One clock coarsely tracks the laser phase using dynamical decoupling; the other refines this estimate using a high-resolution phase measurement. While the former needs to have a high signal-to-noise ratio, the latter clock may operate with any number of particles. The protocol effectively enables minute-long Ramsey interrogation for coherence times of few seconds as provided by the current best ultrastable laser systems. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment, where we interrogate for 0.5 s at a laser coherence time of 77 ms. Here, a single lattice clock is used to emulate synchronous interrogation of two separate clocks in the presence of artificial laser frequency noise. We discuss the frequency instability of a single-ion clock that would result from using the protocol for stabilisation, under these conditions and for minute-long interrogation, and find expected instabilities of σy(τ) = 8 × 10−16(τ/s)−1/2 and σy(τ) = 5 × 10−17(τ/s)−1/2, respectively.
We develop differential measurement protocols that circumvent the laser noise limit in the stability of optical clock comparisons by synchronous probing of two clocks using phase-locked local oscillators. This allows for probe times longer than the laser coherence time, avoids the Dick effect, and supports Heisenberg-limited measurement precision. We present protocols for such frequency comparisons and develop numerical simulations of the protocols with realistic noise sources. These methods provide a route to reduce frequency ratio measurement durations by more than an order of magnitude.
We show that the stability of an optical atomic clock can only be improved by spin squeezed states for ensembles below a critical particle number. This limitation results from a trade-off between measurement noise and instabilities due to limited laser coherence. Our results apply to the case of cyclic Ramsey interrogations on a single atomic ensemble with dead time between each measurement. The combination of analytical models for projection noise, dead time noise (Dick effect) and laser phase noise allows quantitative predictions of the critical particle number and the optimal clock stability for a given dead time and laser noise. Our analytical predictions are confirmed by numerical simulations of the closed servo loop of an optical atomic clock.
Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.
We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.