Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Spin squeezing can only improve clocks with small atom number

Marius Schulte, Christian Lisdat, Piet O. Schmidt, Uwe Sterr, Klemens Hammerer

Published Nov 3, 2019• 0 citations
OpenAlex

Abstract

We show that the stability of an optical atomic clock can only be improved by spin squeezed states for ensembles below a critical particle number. This limitation results from a trade-off between measurement noise and instabilities due to limited laser coherence. Our results apply to the case of cyclic Ramsey interrogations on a single atomic ensemble with dead time between each measurement. The combination of analytical models for projection noise, dead time noise (Dick effect) and laser phase noise allows quantitative predictions of the critical particle number and the optimal clock stability for a given dead time and laser noise. Our analytical predictions are confirmed by numerical simulations of the closed servo loop of an optical atomic clock.

Related papers

Prospects and challenges for squeezing-enhanced optical atomic clocks

Marius Schulte, Christian Lisdat, Piet O. Schmidt +2 more

Optical atomic clocks are a driving force for precision measurements due to the high accuracy and stability demonstrated in recent years. While further improvements to the stability have been envisioned by using entangled atoms, squeezing the quantum mechanical projection noise, evaluating the overall gain must incorporate essential features of an atomic clock. Here, we investigate the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we report here quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in good agreement with numerical simulations of the closed servo-loop. We find that for usual cyclic Ramsey interrogation of single atomic ensembles with dead time, even with the current most stable lasers spin squeezing can only improve the clock stability for ensembles below a critical atom number of about one thousand in an optical Sr lattice clock. Even with a future improvement of the laser performance by one order of magnitude the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers.

arXiv:1911.00882•Nature Communications•Nov 24, 2020•56 citations

Prospects and challenges for squeezing-enhanced optical atomic clocks

Schulte, Marius, Christian Lisdat, Piet O. Schmidt +2 more

Optical atomic clocks are a driving force for precision measurements due to the high accuracy and stability demonstrated in recent years. While further improvements to the stability have been envisioned by using entangled atoms, squeezing the quantum mechanical projection noise, evaluating the overall gain must incorporate essential features of an atomic clock. Here, we investigate the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we report here quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in good agreement with numerical simulations of the closed servo-loop. We find that for usual cyclic Ramsey interrogation of single atomic ensembles with dead time, even with the current most stable lasers spin squeezing can only improve the clock stability for ensembles below a critical atom number of about one thousand in an optical Sr lattice clock. Even with a future improvement of the laser performance by one order of magnitude the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers. © 2020, The Author(s).

•Jan 1, 2020•44 citations

Heisenberg-Limited Noisy Atomic Clock Using a Hybrid Coherent and Squeezed State Protocol

Luca Pezzè, Augusto Smerzi

We propose a hybrid quantum-classical atomic clock where the interrogation of atoms prepared in a spin-coherent (or weakly squeezed) state is used to feed back one or more highly spin-squeezed atomic states toward their optimal phase-sensitivity point. The hybrid clock overcomes the stability of a single Ramsey clock using coherent or optimal spin-squeezed states and reaches a Heisenberg-limited stability while avoiding nondestructive measurements. When optimized with respect to the total number of particles, the protocol surpasses the state-of-the-art proposals that use Greenberger-Horne-Zeilinger or NOON states. We compare analytical predictions with numerical simulations of clock operations, including correlated 1/f local oscillator noise.

arXiv:2003.10943•Physical Review Letters•Nov 19, 2020•56 citations

Improved absolute clock stability by the joint interrogation of two atomic ensembles

Weidong Li, Shuyuan Wu, Augusto Smerzi +1 more

Improving the clock stability is of fundamental importance for the development of quantum-enhanced metrology. One of the main limitations arises from the randomly fluctuating local oscillator (LO) frequency, which introduces ``phase slips'' for long interrogation times and hence the failure of the frequency-feedback loop. Here we propose a strategy to improve the stability of atomic clocks by interrogating two atomic ensembles sharing the same LO. The two ensembles are prepared in coherent spin states pointing along orthogonal directions in the Bloch sphere. While standard Ramsey interrogation can only determine phases unambiguously in the interval $[\ensuremath{-}\ensuremath{\pi}/2,\ensuremath{\pi}/2]$, the joint interrogation allows for an extension to $[\ensuremath{-}\ensuremath{\pi},\ensuremath{\pi}]$, resulting in a relaxed restriction of the Ramsey time and improvement of absolute clock stability. Theoretical predictions are supported by ab initio numerical simulation for white and correlated LO noise. While our basic protocol uses uncorrelated atoms, we further extended it to include spin-squeezing and further improving the scaling of clock stability with the number of atoms. Our protocol can be readily tested in current state-of-the-art experiments.

arXiv:2104.14309•Physical Review A•May 19, 2022•8 citations

Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level

Xiao-Yong Liu, Peng Liu, Jie Li +20 more

Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.

Physical Review Letters•Nov 26, 2025•9 citations

Entanglement in Ramsey interferometry, optical atomic clocks and trapped ions

Schulte, Marius

This thesis describes new results on the entanglement of atomic spins in Ramsey interferometry, optical atomic clocks and trapped ions. It is divided into three parts: First, we investigate improvements to conventional Ramsey interferometry with entanglement and adding only rotations of the collective spin to adjust the signal and measurement directions. The geometric degrees of freedom, connected to the rotations, are analytically optimized for a large class of generalized Ramsey protocols to allow efficient optimization of all parameters. Besides a unification of existing approaches, the main result is that there is only one new protocol, where a previously unused double inversion is applied. Studies of the local sensitivity show that this protocol reaches the fundamental quantum Fisher information limit and is yet robust against errors during preparation and measurement. In the second section we investigate the conditions under which optical atomic clocks exhibit increased long-term stability when applying weakly entangled, spin squeezed states. We discuss the common case of an atomic clock with a single ensemble, typical Brownian frequency noise and finite dead time. Theoretical modelling of the servo loop allows quantitative predictions of the optimal stability for given values of dead time and laser noise, in very good agreement with numerical simulations of the closed feedback loop. The main result is that, even with the current most stable lasers, the clock stability can only be improved for ensembles below a critical atom number of about one thousand in optical Sr lattice clocks. Even with a future improvement of the laser performance by one order of magnitude, the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers. Thus the last section considers the robust generation of entanglement in ion traps. An error budget including relevant experimental error sources is calculated for state-of-the-art quantum gates, driven by oscillating microwave gradients in surface traps. Amplitude modulation of the driving fields is shown to efficiently counteract the current limitations from motional mode instability. The predicted increase of the gate quality was demonstrated by the group of C. Ospelkaus at PTB Braunschweig, who measured gates with errors as low as ~ 10^(-3). In a similar approach, interactions between spin and motion can also be generated by combining oscillating rf-fields with a static magnetic field gradient. Penning traps designed for precision spectroscopy already feature large magnetic field gradients at the edge of a magnetic bottle configuration. We present parameters and conditions under which laser-free coupling of spin and quantized motion for (anti-)protons is possible at these points, in a step towards quantum logic spectroscopy for (anti-)protons.

•Jan 1, 2020•1 citation
We show that the stability of an optical atomic clock can only be improved by spin squeezed states for ensembles below a critical particle number. This limitation results from a trade-off between measurement noise and instabilities due to limited laser coherence. Our results apply to the case of cyclic Ramsey interrogations on a single atomic ensemble with dead time between each measurement. The combination of analytical models for projection noise, dead time noise (Dick effect) and laser phase noise allows quantitative predictions of the critical particle number and the optimal clock stability for a given dead time and laser noise. Our analytical predictions are confirmed by numerical simulations of the closed servo loop of an optical atomic clock.
Optical atomic clocks are a driving force for precision measurements due to the high accuracy and stability demonstrated in recent years. While further improvements to the stability have been envisioned by using entangled atoms, squeezing the quantum mechanical projection noise, evaluating the overall gain must incorporate essential features of an atomic clock. Here, we investigate the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we report here quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in good agreement with numerical simulations of the closed servo-loop. We find that for usual cyclic Ramsey interrogation of single atomic ensembles with dead time, even with the current most stable lasers spin squeezing can only improve the clock stability for ensembles below a critical atom number of about one thousand in an optical Sr lattice clock. Even with a future improvement of the laser performance by one order of magnitude the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers.
Optical atomic clocks are a driving force for precision measurements due to the high accuracy and stability demonstrated in recent years. While further improvements to the stability have been envisioned by using entangled atoms, squeezing the quantum mechanical projection noise, evaluating the overall gain must incorporate essential features of an atomic clock. Here, we investigate the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we report here quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in good agreement with numerical simulations of the closed servo-loop. We find that for usual cyclic Ramsey interrogation of single atomic ensembles with dead time, even with the current most stable lasers spin squeezing can only improve the clock stability for ensembles below a critical atom number of about one thousand in an optical Sr lattice clock. Even with a future improvement of the laser performance by one order of magnitude the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers. © 2020, The Author(s).
We propose a hybrid quantum-classical atomic clock where the interrogation of atoms prepared in a spin-coherent (or weakly squeezed) state is used to feed back one or more highly spin-squeezed atomic states toward their optimal phase-sensitivity point. The hybrid clock overcomes the stability of a single Ramsey clock using coherent or optimal spin-squeezed states and reaches a Heisenberg-limited stability while avoiding nondestructive measurements. When optimized with respect to the total number of particles, the protocol surpasses the state-of-the-art proposals that use Greenberger-Horne-Zeilinger or NOON states. We compare analytical predictions with numerical simulations of clock operations, including correlated 1/f local oscillator noise.
Improving the clock stability is of fundamental importance for the development of quantum-enhanced metrology. One of the main limitations arises from the randomly fluctuating local oscillator (LO) frequency, which introduces ``phase slips'' for long interrogation times and hence the failure of the frequency-feedback loop. Here we propose a strategy to improve the stability of atomic clocks by interrogating two atomic ensembles sharing the same LO. The two ensembles are prepared in coherent spin states pointing along orthogonal directions in the Bloch sphere. While standard Ramsey interrogation can only determine phases unambiguously in the interval $[\ensuremath{-}\ensuremath{\pi}/2,\ensuremath{\pi}/2]$, the joint interrogation allows for an extension to $[\ensuremath{-}\ensuremath{\pi},\ensuremath{\pi}]$, resulting in a relaxed restriction of the Ramsey time and improvement of absolute clock stability. Theoretical predictions are supported by ab initio numerical simulation for white and correlated LO noise. While our basic protocol uses uncorrelated atoms, we further extended it to include spin-squeezing and further improving the scaling of clock stability with the number of atoms. Our protocol can be readily tested in current state-of-the-art experiments.
Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.
This thesis describes new results on the entanglement of atomic spins in Ramsey interferometry, optical atomic clocks and trapped ions. It is divided into three parts: First, we investigate improvements to conventional Ramsey interferometry with entanglement and adding only rotations of the collective spin to adjust the signal and measurement directions. The geometric degrees of freedom, connected to the rotations, are analytically optimized for a large class of generalized Ramsey protocols to allow efficient optimization of all parameters. Besides a unification of existing approaches, the main result is that there is only one new protocol, where a previously unused double inversion is applied. Studies of the local sensitivity show that this protocol reaches the fundamental quantum Fisher information limit and is yet robust against errors during preparation and measurement. In the second section we investigate the conditions under which optical atomic clocks exhibit increased long-term stability when applying weakly entangled, spin squeezed states. We discuss the common case of an atomic clock with a single ensemble, typical Brownian frequency noise and finite dead time. Theoretical modelling of the servo loop allows quantitative predictions of the optimal stability for given values of dead time and laser noise, in very good agreement with numerical simulations of the closed feedback loop. The main result is that, even with the current most stable lasers, the clock stability can only be improved for ensembles below a critical atom number of about one thousand in optical Sr lattice clocks. Even with a future improvement of the laser performance by one order of magnitude, the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers. Thus the last section considers the robust generation of entanglement in ion traps. An error budget including relevant experimental error sources is calculated for state-of-the-art quantum gates, driven by oscillating microwave gradients in surface traps. Amplitude modulation of the driving fields is shown to efficiently counteract the current limitations from motional mode instability. The predicted increase of the gate quality was demonstrated by the group of C. Ospelkaus at PTB Braunschweig, who measured gates with errors as low as ~ 10^(-3). In a similar approach, interactions between spin and motion can also be generated by combining oscillating rf-fields with a static magnetic field gradient. Penning traps designed for precision spectroscopy already feature large magnetic field gradients at the edge of a magnetic bottle configuration. We present parameters and conditions under which laser-free coupling of spin and quantized motion for (anti-)protons is possible at these points, in a step towards quantum logic spectroscopy for (anti-)protons.