Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1911.02935 · Physical Review Applied

General Methods for Suppressing the Light Shift in Atomic Clocks Using Power Modulation

Valeriy I. Yudin, M. Yu. Basalaev, А. В. Тайченачев, J. W. Pollock, Zachary L. Newman, M. Shuker, Azure Hansen, Matthew T. Hummon, Rodolphe Boudot, Elizabeth A. Donley, John E. Kitching

Published Aug 3, 2020• 43 citations
arXivHTMLPDF

Abstract

We show that the light shift in atomic clocks can be suppressed using time variation of the interrogation field intensity. By measuring the clock output at two intensity levels, error signals can be generated that simultaneously stabilize a local oscillator to an atomic transition and correct for the shift of this transition caused by the interrogating optical field. These methods are suitable for optical clocks using one- and two-photon transitions, as well as for microwave clocks based on coherent population trapping or direct interrogation. The proposed methods can be widely used both for high-precision scientific instruments and for a wide range of commercial clocks, including chip-scale atomic clocks.

DOI
10.1103/physrevapplied.14.024001

Related papers

Reduction of light shifts in Ramsey spectroscopy with a combined error signal

M. Shuker, J. W. Pollock, Rodolphe Boudot +4 more

Light-induced frequency shifts can be a key limiting contribution to the mid- and long-term frequency instabilities in atomic clocks. In this letter, we demonstrate the experimental implementation of the combined error signal interrogation protocol to a cold-atom clock based on coherent population trapping (CPT) and Ramsey spectroscopy. The method uses a single error signal that results from the normalized combination of two error signals extracted from two Ramsey sequences of different dark periods. The single combined error signal is used to stabilize the atomic clock frequency. Compared to the standard Ramsey-CPT interrogation, this method reduces the clock frequency sensitivity to light-shift variations by more than one order of magnitude. This method can be applied in various kinds of Ramsey-based atomic clocks, sensors, and instruments.

arXiv:1903.00566•Applied Physics Letters•Apr 8, 2019•29 citations

Active light shift stabilization in modulated CPT clocks.

Vishal Shah, Peter D. D. Schwindt, Vladislav P. Gerginov +3 more

We demonstrate a simple technique to significantly improve the long-term frequency stability in atomic clocks based on coherent population trapping (CPT). In this technique, a servo is used to control the local oscillator power level in such a way that the optical spectrum generates no net light shift. This ensures that the clock frequency is always given by the atomic resonance frequency that is not perturbed by the incident light fields.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2006•9 citations

Protocol for Light-Shift Compensation in a Continuous-Wave Microcell Atomic Clock

Moustafa Abdel Hafiz, Rémy Vicarini, Nicolas Passilly +7 more

Light shifts are known to be an important limitation to the mid- and long-term fractional frequency stability of different types of atomic clocks. In this article, we demonstrate the experimental implementation of an anti-light-shift interrogation protocol onto a continuous-wave (cw) microcell atomic clock based on coherent population trapping (CPT). The method, inspired by the autobalanced Ramsey spectroscopy technique demonstrated in pulsed atomic clocks, consists in the extraction of atomic based information from two successive light-shifted clock frequencies obtained at two different laser-power values. Two error signals, computed from the linear combination of signals acquired along a symmetric sequence, are managed in a dual-loop configuration to generate a clock frequency free from light shift. Using this method, the sensitivity of the clock frequency to both laser-power and microwave-power variations can be reduced by more than an order of magnitude compared to normal operation. In the present experiment, the consideration of the nonlinear light-shift dependence allows enhancement of the light-shift mitigation. The implemented technique allows an improvement of the clock Allan deviation for time scales higher than 1000 s. This method can be applied in various kinds of atomic clocks such as CPT-based atomic clocks, double-resonance $\mathrm{Rb}$ clocks, or cell-stabilized lasers.

arXiv:2005.05096•Physical Review Applied•Sep 8, 2020•40 citations

Reduction of light shifts in a cold-atom CPT clock

Maojie Li, Zhu Ma, Jiatao Wu +5 more

Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.

Journal of Physics B Atomic Molecular and Optical Physics•Apr 23, 2024•4 citations

Active Suppression of the Light Shift in an Atomic Clock Based on Coherent Population Trapping in 87Rb Vapor Using the Phase Jump Technique

Daba A. Radnatarov, Sergey M Kobtsev, Valeriy Andryushkov +4 more

The active suppression of light shift of the reference coherent population trapping (CPT) resonance in 87Rb vapor to improve the long-term stability of compact atomic clocks has been demonstrated experimentally. The approach is based on the phase jump technique used to synthesize an error signal, which is proportional to the light shift of the CPT resonance, from an optical transmission signal. The use of this error signal in an additional feedback loop allows one to stabilize the amplitude of a microwave signal for the phase modulation of laser radiation near a value at which the light shift of the CPT resonance is absent. This technique has made it possible to reduce the long-term instability of CPT atomic clocks in our experiments by a factor of 15 at an integration time of 10 000–20 000 s.

Письма в Журнал экспериментальной и теоретической физики•Apr 15, 2023•0 citations

Active Suppression of the Light Shift in an Atomic Clock Based on Coherent Population Trapping in 87Rb Vapor Using the Phase Jump Technique

Daba A. Radnatarov, Sergey M Kobtsev, Valeriy Andryushkov +4 more

The active suppression of light shift of the reference coherent population trapping (CPT) resonance in87Rb vapor to improve the long-term stability of compact atomic clocks has been demonstrated experimentally. The approach is based on the phase jump technique used to synthesize an error signal, which is proportional to the light shift of the CPT resonance, from an optical transmission signal. The use of this error signal in an additional feedback loop allows one to stabilize the amplitude of a microwave signal for the phase modulation of laser radiation near a value at which the light shift of the CPT resonance is absent. This technique has made it possible to reduce the long-term instability of CPT atomic clocks in our experiments by a factor of 15 at an integration time of 10 000–20 000 s.

Journal of Experimental and Theoretical Physics Letters•Apr 1, 2023•11 citations
We show that the light shift in atomic clocks can be suppressed using time variation of the interrogation field intensity. By measuring the clock output at two intensity levels, error signals can be generated that simultaneously stabilize a local oscillator to an atomic transition and correct for the shift of this transition caused by the interrogating optical field. These methods are suitable for optical clocks using one- and two-photon transitions, as well as for microwave clocks based on coherent population trapping or direct interrogation. The proposed methods can be widely used both for high-precision scientific instruments and for a wide range of commercial clocks, including chip-scale atomic clocks.
Light-induced frequency shifts can be a key limiting contribution to the mid- and long-term frequency instabilities in atomic clocks. In this letter, we demonstrate the experimental implementation of the combined error signal interrogation protocol to a cold-atom clock based on coherent population trapping (CPT) and Ramsey spectroscopy. The method uses a single error signal that results from the normalized combination of two error signals extracted from two Ramsey sequences of different dark periods. The single combined error signal is used to stabilize the atomic clock frequency. Compared to the standard Ramsey-CPT interrogation, this method reduces the clock frequency sensitivity to light-shift variations by more than one order of magnitude. This method can be applied in various kinds of Ramsey-based atomic clocks, sensors, and instruments.
Light shifts are known to be an important limitation to the mid- and long-term fractional frequency stability of different types of atomic clocks. In this article, we demonstrate the experimental implementation of an anti-light-shift interrogation protocol onto a continuous-wave (cw) microcell atomic clock based on coherent population trapping (CPT). The method, inspired by the autobalanced Ramsey spectroscopy technique demonstrated in pulsed atomic clocks, consists in the extraction of atomic based information from two successive light-shifted clock frequencies obtained at two different laser-power values. Two error signals, computed from the linear combination of signals acquired along a symmetric sequence, are managed in a dual-loop configuration to generate a clock frequency free from light shift. Using this method, the sensitivity of the clock frequency to both laser-power and microwave-power variations can be reduced by more than an order of magnitude compared to normal operation. In the present experiment, the consideration of the nonlinear light-shift dependence allows enhancement of the light-shift mitigation. The implemented technique allows an improvement of the clock Allan deviation for time scales higher than 1000 s. This method can be applied in various kinds of atomic clocks such as CPT-based atomic clocks, double-resonance Rb\mathrm{Rb}Rb clocks, or cell-stabilized lasers.
Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.
The active suppression of light shift of the reference coherent population trapping (CPT) resonance in 87Rb vapor to improve the long-term stability of compact atomic clocks has been demonstrated experimentally. The approach is based on the phase jump technique used to synthesize an error signal, which is proportional to the light shift of the CPT resonance, from an optical transmission signal. The use of this error signal in an additional feedback loop allows one to stabilize the amplitude of a microwave signal for the phase modulation of laser radiation near a value at which the light shift of the CPT resonance is absent. This technique has made it possible to reduce the long-term instability of CPT atomic clocks in our experiments by a factor of 15 at an integration time of 10 000–20 000 s.
The active suppression of light shift of the reference coherent population trapping (CPT) resonance in87Rb vapor to improve the long-term stability of compact atomic clocks has been demonstrated experimentally. The approach is based on the phase jump technique used to synthesize an error signal, which is proportional to the light shift of the CPT resonance, from an optical transmission signal. The use of this error signal in an additional feedback loop allows one to stabilize the amplitude of a microwave signal for the phase modulation of laser radiation near a value at which the light shift of the CPT resonance is absent. This technique has made it possible to reduce the long-term instability of CPT atomic clocks in our experiments by a factor of 15 at an integration time of 10 000–20 000 s.