Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1902.09883

Active Interferometry with Gaussian Channels

Richard Howl, Ivette Fuentes

Published Feb 26, 2019• 3 citations
arXivHTMLPDF

Abstract

We consider an interferometer that contains active elements, such as a parametric amplifier, with general two-mode Gaussian unitary channels rather than the usually considered phase-shift channel. We concentrate on a scheme based on the recently proposed pumped-up SU(1,1) active interferometer where all input particles participate in the parameter estimation, and from which a conventional SU(1,1) interferometer is a limiting case. Using the covariance matrix formalism, we derive the quantum Fisher information of this active interferometer with a general two-mode Gaussian unitary channel, as well as the sensitivity for a number-sum measurement scheme, finding simple expressions for the latter. As an example application, we apply our results to Bose-Einstein condensates (BECs), and in particular a BEC gravitational-wave detector based on resonance, finding that the sensitivity of the detector can be improved by several orders of magnitude with this new interferometry scheme.

DOI
10.48550/arxiv.1902.09883

Related papers

Gaussian-state interferometry with passive and active elements

Carlo Sparaciari, Stefano Olivares, Matteo G. A. Paris

We address the precision of optical interferometers fed by quantum and semiclassical Gaussian states involving passive and/or active elements, such as beam splitters, photodetectors, and optical parametric amplifiers. We first address the ultimate bounds to precision by discussing the behavior of the quantum Fisher information. We then consider photodetection at the output and calculate the sensitivity of the interferometers taking into account the nonunit quantum efficiency of the detectors. Our results show that in the ideal case of photon number detectors with unit quantum efficiency the best configuration is the symmetric one, namely, a passive (active) interferometer with a passive (active) detection stage: in this case one may achieve Heisenberg scaling of sensitivity by suitably optimizing over Gaussian states at the input. On the other hand, in the realistic case of detectors with nonunit quantum efficiency, the performances of the passive scheme are unavoidably degraded, whereas detectors involving optical parametric amplifiers allow us to fully compensate for the presence of loss in the detection stage, thus restoring the Heisenberg scaling.

arXiv:1510.07716•Physical Review A•Feb 5, 2016•95 citations

Enhancement of Sensitivity by Initial Phase Matching in SU(1,1) Interferometers*

Xiao Xiao, Hongbin Liang, Guolong Li +1 more

Abstract We derive a general phase-matching condition (PMC) for enhancement of sensitivity in SU(1,1) interferometers. Under this condition, the quantum Fisher information (QFI) of two-mode SU(1,1) interferometry becomes maximal with respect to the relative phase of two modes, for the case of an arbitrary state in one input port and an even (odd) state in the other port, and the phase sensitivity is enhanced. We also find that optimal parameters can let the QFI in some areas achieve the Heisenberg limit for both pure and mixed initial states. As examples, we consider several input states: coherent and even coherent states, squeezed vacuum and even coherent states, squeezed thermal and even coherent states. Furthermore, in the realistic scenario of the photon loss channel, we investigate the effect of photon losses on QFI with numerical studies. We find the PMC remains unchanged and is not affected by the transmission coefficients for the above input states. Our results suggest that the PMC can exist in various kinds of interferometers and the phase-matching is robust to even strong photon losses.

Communications in Theoretical Physics•Jan 1, 2019•10 citations

Pumped-Up SU(1,1) Interferometry

Stuart S. Szigeti, Robert J. Lewis-Swan, Simon A. Haine

Although SU(1,1) interferometry achieves Heisenberg-limited sensitivities, it suffers from one major drawback: Only those particles outcoupled from the pump mode contribute to the phase measurement. Since the number of particles outcoupled to these "side modes" is typically small, this limits the interferometer's absolute sensitivity. We propose an alternative "pumped-up" approach where all the input particles participate in the phase measurement and show how this can be implemented in spinor Bose-Einstein condensates and hybrid atom-light systems-both of which have experimentally realized SU(1,1) interferometry. We demonstrate that pumped-up schemes are capable of surpassing the shot-noise limit with respect to the total number of input particles and are never worse than conventional SU(1,1) interferometry. Finally, we show that pumped-up schemes continue to excel-both absolutely and in comparison to conventional SU(1,1) interferometry-in the presence of particle losses, poor particle-resolution detection, and noise on the relative phase difference between the two side modes. Pumped-up SU(1,1) interferometry therefore pushes the advantages of conventional SU(1,1) interferometry into the regime of high absolute sensitivity, which is a necessary condition for useful quantum-enhanced devices.

arXiv:1610.07689•Physical Review Letters•Apr 11, 2017•137 citations

Precision of Parameter Estimation in Quantum Metrology

Chenglong You

The fundamental precision limit of an interferometer is crucial since it bounds the best possible sensitivity one could achieve using such a device. This thesis will focus on several different interferometers and try to give the ultimate precision bounds by carefully counting all the resources used in the interferometers. The thesis begins with the basics of the quantum state of light. The fundamentals of quantum metrology are also reviewed and discussed. More specifically, the terminology of classical and quantum Cram\'er-Rao bound and classical and quantum Fisher information are introduced. Chapter 3 discusses the conclusive precision bounds in two-mode interferometer such as Mach-Zehnder interferometer (MZI) and SU(1,1) interferometer. I revisit the quantum Fisher information approach of these two interferometers and show the discrepancy of phase sensitivity on the physically same setup. Then I establish fundamental precision estimation bounds for such device, due to the reason that many works of literature fail to accurately count the resources and knowledge of phase-to-be-estimated used in the interferometers. The analysis suggests that for a MZI, one can never do better than SNL in phase sensitivity, when an input to one of the two ports is the vacuum. If one does not allow the detector to use any external phase reference or power resource, then the precision is limited by the SNL. For a SU(1,1) interferometer, firstly, when one of the input states is restricted to be a vacuum state, I showed that by using either the phase-averaging method or the quantum Fisher information matrix method, different phase configurations of the SU(1,1) interferometer result in the same QFI. Secondly, I compared the results of the phase-averaging method and the quantum Fisher information matrix method, and then I argued that for an SU(1,1) interferometer, phase averaging or quantum Fisher information matrix method is generally required, and they are equivalent. Finally, I used the quantum Fisher information matrix method to calculate the precision limit for other common input states, such as two coherent state inputs or coherent state with squeezed vacuum inputs. In chapter 4, I will consider a passive multi-mode interferometer for multiparameter phase estimation. It was suggested that optical networks with relatively inexpensive overhead---single photon Fock states, passive optical elements, and single photon detection---can show significant improvements over classical strategies for single-parameter estimation, when the number of modes in the network is small. In this chapter, I analytically compute the quantum Cramer-Rao bound to show these

Civil War Book Review•Mar 18, 2019•0 citations

Multiparameter Gaussian quantum metrology

Rosanna Nichols, Pietro Liuzzo-Scorpo, Paul A. Knott +1 more

We investigate the ultimate precision achievable in Gaussian quantum metrology. We derive general analytical expressions for the quantum Fisher information matrix and for the measurement compatibility condition, ensuring asymptotic saturability of the quantum Cram\'er-Rao bound, for the estimation of multiple parameters encoded in multimode Gaussian states. We then apply our results to the joint estimation of a phase shift and two parameters characterizing Gaussian phase covariant noise in optical interferometry. In such a scheme, we show that two-mode displaced squeezed input probes with optimally tuned squeezing and displacement fulfill the measurement compatibility condition and enable the simultaneous estimation of all three parameters, with an advantage over individual estimation schemes that quickly rises with increasing mean energy of the probes.

arXiv:1711.09132•Physical Review A•Jul 11, 2018•137 citations

Bounds to precision for quantum interferometry with Gaussian states and operations

Carlo Sparaciari, Stefano Olivares, Matteo G. A. Paris

We address high-precision measurements by active and passive interferometric schemes based on Gaussian states and operations. In particular, we look for the best states to be injected into their ports according to the quantum Cramér–Rao bound, i.e., maximizing the quantum Fisher information over all the involved parameters, given a constraint on the overall mean number of photons entering into the interferometer. We found that for passive interferometers involving only beam splitters, the optimal input leading to Heisenberg scaling is a pair of identical squeezed-coherent states with at most one-third of the total energy employed in squeezing. For active interfer-ometers involving optical amplifiers, input coherent signals are enough to achieve Heisenberg scaling, given an optimal value of the amplification gain. For passive schemes our results clarify the role of squeezing in improving both the reference phase and the signal phase of an interferometer. © 2015 Optical Society of America OCIS codes: (270.6570) Squeezed states; (270.5570) Quantum detectors; (190.4970) Parametric oscillators and amplifiers; (120.3180) Interferometry.

Journal of the Optical Society of America B•Jun 5, 2015•63 citations
We consider an interferometer that contains active elements, such as a parametric amplifier, with general two-mode Gaussian unitary channels rather than the usually considered phase-shift channel. We concentrate on a scheme based on the recently proposed pumped-up SU(1,1) active interferometer where all input particles participate in the parameter estimation, and from which a conventional SU(1,1) interferometer is a limiting case. Using the covariance matrix formalism, we derive the quantum Fisher information of this active interferometer with a general two-mode Gaussian unitary channel, as well as the sensitivity for a number-sum measurement scheme, finding simple expressions for the latter. As an example application, we apply our results to Bose-Einstein condensates (BECs), and in particular a BEC gravitational-wave detector based on resonance, finding that the sensitivity of the detector can be improved by several orders of magnitude with this new interferometry scheme.
We address the precision of optical interferometers fed by quantum and semiclassical Gaussian states involving passive and/or active elements, such as beam splitters, photodetectors, and optical parametric amplifiers. We first address the ultimate bounds to precision by discussing the behavior of the quantum Fisher information. We then consider photodetection at the output and calculate the sensitivity of the interferometers taking into account the nonunit quantum efficiency of the detectors. Our results show that in the ideal case of photon number detectors with unit quantum efficiency the best configuration is the symmetric one, namely, a passive (active) interferometer with a passive (active) detection stage: in this case one may achieve Heisenberg scaling of sensitivity by suitably optimizing over Gaussian states at the input. On the other hand, in the realistic case of detectors with nonunit quantum efficiency, the performances of the passive scheme are unavoidably degraded, whereas detectors involving optical parametric amplifiers allow us to fully compensate for the presence of loss in the detection stage, thus restoring the Heisenberg scaling.
Abstract We derive a general phase-matching condition (PMC) for enhancement of sensitivity in SU(1,1) interferometers. Under this condition, the quantum Fisher information (QFI) of two-mode SU(1,1) interferometry becomes maximal with respect to the relative phase of two modes, for the case of an arbitrary state in one input port and an even (odd) state in the other port, and the phase sensitivity is enhanced. We also find that optimal parameters can let the QFI in some areas achieve the Heisenberg limit for both pure and mixed initial states. As examples, we consider several input states: coherent and even coherent states, squeezed vacuum and even coherent states, squeezed thermal and even coherent states. Furthermore, in the realistic scenario of the photon loss channel, we investigate the effect of photon losses on QFI with numerical studies. We find the PMC remains unchanged and is not affected by the transmission coefficients for the above input states. Our results suggest that the PMC can exist in various kinds of interferometers and the phase-matching is robust to even strong photon losses.
Although SU(1,1) interferometry achieves Heisenberg-limited sensitivities, it suffers from one major drawback: Only those particles outcoupled from the pump mode contribute to the phase measurement. Since the number of particles outcoupled to these "side modes" is typically small, this limits the interferometer's absolute sensitivity. We propose an alternative "pumped-up" approach where all the input particles participate in the phase measurement and show how this can be implemented in spinor Bose-Einstein condensates and hybrid atom-light systems-both of which have experimentally realized SU(1,1) interferometry. We demonstrate that pumped-up schemes are capable of surpassing the shot-noise limit with respect to the total number of input particles and are never worse than conventional SU(1,1) interferometry. Finally, we show that pumped-up schemes continue to excel-both absolutely and in comparison to conventional SU(1,1) interferometry-in the presence of particle losses, poor particle-resolution detection, and noise on the relative phase difference between the two side modes. Pumped-up SU(1,1) interferometry therefore pushes the advantages of conventional SU(1,1) interferometry into the regime of high absolute sensitivity, which is a necessary condition for useful quantum-enhanced devices.
The fundamental precision limit of an interferometer is crucial since it bounds the best possible sensitivity one could achieve using such a device. This thesis will focus on several different interferometers and try to give the ultimate precision bounds by carefully counting all the resources used in the interferometers. The thesis begins with the basics of the quantum state of light. The fundamentals of quantum metrology are also reviewed and discussed. More specifically, the terminology of classical and quantum Cram\'er-Rao bound and classical and quantum Fisher information are introduced. Chapter 3 discusses the conclusive precision bounds in two-mode interferometer such as Mach-Zehnder interferometer (MZI) and SU(1,1) interferometer. I revisit the quantum Fisher information approach of these two interferometers and show the discrepancy of phase sensitivity on the physically same setup. Then I establish fundamental precision estimation bounds for such device, due to the reason that many works of literature fail to accurately count the resources and knowledge of phase-to-be-estimated used in the interferometers. The analysis suggests that for a MZI, one can never do better than SNL in phase sensitivity, when an input to one of the two ports is the vacuum. If one does not allow the detector to use any external phase reference or power resource, then the precision is limited by the SNL. For a SU(1,1) interferometer, firstly, when one of the input states is restricted to be a vacuum state, I showed that by using either the phase-averaging method or the quantum Fisher information matrix method, different phase configurations of the SU(1,1) interferometer result in the same QFI. Secondly, I compared the results of the phase-averaging method and the quantum Fisher information matrix method, and then I argued that for an SU(1,1) interferometer, phase averaging or quantum Fisher information matrix method is generally required, and they are equivalent. Finally, I used the quantum Fisher information matrix method to calculate the precision limit for other common input states, such as two coherent state inputs or coherent state with squeezed vacuum inputs. In chapter 4, I will consider a passive multi-mode interferometer for multiparameter phase estimation. It was suggested that optical networks with relatively inexpensive overhead---single photon Fock states, passive optical elements, and single photon detection---can show significant improvements over classical strategies for single-parameter estimation, when the number of modes in the network is small. In this chapter, I analytically compute the quantum Cramer-Rao bound to show these
We investigate the ultimate precision achievable in Gaussian quantum metrology. We derive general analytical expressions for the quantum Fisher information matrix and for the measurement compatibility condition, ensuring asymptotic saturability of the quantum Cram\'er-Rao bound, for the estimation of multiple parameters encoded in multimode Gaussian states. We then apply our results to the joint estimation of a phase shift and two parameters characterizing Gaussian phase covariant noise in optical interferometry. In such a scheme, we show that two-mode displaced squeezed input probes with optimally tuned squeezing and displacement fulfill the measurement compatibility condition and enable the simultaneous estimation of all three parameters, with an advantage over individual estimation schemes that quickly rises with increasing mean energy of the probes.
We address high-precision measurements by active and passive interferometric schemes based on Gaussian states and operations. In particular, we look for the best states to be injected into their ports according to the quantum Cramér–Rao bound, i.e., maximizing the quantum Fisher information over all the involved parameters, given a constraint on the overall mean number of photons entering into the interferometer. We found that for passive interferometers involving only beam splitters, the optimal input leading to Heisenberg scaling is a pair of identical squeezed-coherent states with at most one-third of the total energy employed in squeezing. For active interfer-ometers involving optical amplifiers, input coherent signals are enough to achieve Heisenberg scaling, given an optimal value of the amplification gain. For passive schemes our results clarify the role of squeezing in improving both the reference phase and the signal phase of an interferometer. © 2015 Optical Society of America OCIS codes: (270.6570) Squeezed states; (270.5570) Quantum detectors; (190.4970) Parametric oscillators and amplifiers; (120.3180) Interferometry.