Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1610.07689 · Physical Review Letters

Pumped-Up SU(1,1) Interferometry

Stuart S. Szigeti, Robert J. Lewis-Swan, Simon A. Haine

Published Apr 11, 2017• 135 citations
arXivHTMLPDF

Abstract

Although SU(1,1) interferometry achieves Heisenberg-limited sensitivities, it suffers from one major drawback: Only those particles outcoupled from the pump mode contribute to the phase measurement. Since the number of particles outcoupled to these "side modes" is typically small, this limits the interferometer's absolute sensitivity. We propose an alternative "pumped-up" approach where all the input particles participate in the phase measurement and show how this can be implemented in spinor Bose-Einstein condensates and hybrid atom-light systems-both of which have experimentally realized SU(1,1) interferometry. We demonstrate that pumped-up schemes are capable of surpassing the shot-noise limit with respect to the total number of input particles and are never worse than conventional SU(1,1) interferometry. Finally, we show that pumped-up schemes continue to excel-both absolutely and in comparison to conventional SU(1,1) interferometry-in the presence of particle losses, poor particle-resolution detection, and noise on the relative phase difference between the two side modes. Pumped-up SU(1,1) interferometry therefore pushes the advantages of conventional SU(1,1) interferometry into the regime of high absolute sensitivity, which is a necessary condition for useful quantum-enhanced devices.

DOI
10.1103/physrevlett.118.150401

Related papers

SU(1,1) interferometry via four-wave mixing in Rb

Travis Horrom, Brian E. Anderson, Prasoon Gupta +1 more

Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].

•Jan 1, 2015•3 citations

Spin-Mixing Interferometry with Bose-Einstein Condensates

Marco Gabbrielli, Luca Pezzè, Augusto Smerzi

Unstable spinor Bose-Einstein condensates are ideal candidates to create nonlinear three-mode interferometers. Our analysis goes beyond the standard SU(1,1) parametric approach and therefore provides the regime of parameters where sub-shot-noise sensitivities can be reached with respect to the input total average number of particles. Decoherence due to particle losses and finite detection efficiency are also considered.

arXiv:1503.08582•Physical Review Letters•Oct 16, 2015•93 citations

Ultrasensitive Two-Mode Interferometry with Single-Mode Number Squeezing

Luca Pezzè, Augusto Smerzi

A major challenge of the phase estimation problem is the engineering of high-intensity entangled probe states. The goal is to significantly enhance above the shot-noise limit the sensitivity of two-mode interferometers. Here we show that this can be achieved by squeezing in input, and then measuring in output, the population fluctuations of a single mode. The second input mode can be left as an arbitrary nonvacuum (e.g., a bright coherent) state. This two-mode state belongs to a novel class of particle-entangled states which are not spin squeezed. Already a 2.4 db gain above shot noise can be obtained when just a single-particle Fock state is injected into the empty input port of a classical interferometer configuration. Higher gains, up to the Heisenberg limit, can be reached with squeezed states of a larger number of particles. We finally study the robustness of this protocol with respect to detection noise.

Physical Review Letters•Apr 16, 2013•132 citations

Hybrid SU(1,1) Interferometry in Optomechanics

Chao Meng, Emil Zeuthen, Polina R. Sharapova

In nondegenerate SU(1,1) interferometers, beam splitters are replaced by two-mode squeezers, enabling sub-shot-noise sensitivity without input squeezing and robustness to detection losses by quantum entanglement. We propose a hybrid implementation in optomechanics where one "arm" is a mechanical mode undergoing two consecutive, mode-matched interactions with a traveling optical field (constituting the other arm). Such engineered interactions allow for sub-shot-noise phase detection even in the presence of mechanical thermal noise and optical losses, advancing precision interferometry in hybrid systems.

arXiv:2509.22248•Physical Review Letters•Apr 23, 2026•0 citations

Effect of losses on the performance of an SU(1,1) interferometer

Alberto M. Marino, Neil Corzo, Paul D. Lett

We study the effect of losses on the phase sensitivity of the SU(1,1) interferometer for different configurations. We find that this type of interferometer is robust against losses that result from an inefficient detection system. This type of loss only introduces an overall prefactor to the sensitivity but does not change the $1/n$ scaling, where $n$ is the average number of particles inside the interferometer, characteristic of the Heisenberg limit. In addition, we show that under some conditions the SU(1,1) interferometer with coherent state inputs is also robust against internal losses. These results show that the SU(1,1) interferometer is a viable candidate for experimentally reaching the Heisenberg limit with current technology. Possible implementations of this interferometer using four-wave mixing in atomic vapors or an atom interferometer in a spinor Bose-Einstein condensate are compared.

Physical Review A•Aug 24, 2012•179 citations

Spinor Bose-Einstein-condensate phase-sensitive amplifier for SU(1,1) interferometry

Jonathan Wrubel, Arne Schwettmann, Donald P. Fahey +6 more

The SU(1,1) interferometer was originally conceived as a Mach-Zehnder interferometer with the beam splitters replaced by parametric amplifiers. The parametric amplifiers produce states with correlations that result in enhanced phase sensitivity. $F=1$ spinor Bose-Einstein condensates (BECs) can serve as the parametric amplifiers for an atomic version of such an interferometer by collisionally producing entangled pairs of $|F=1,m=\ifmmode\pm\else\textpm\fi{}1\ensuremath{\rangle}$ atoms. We simulate the effect of single- and double-sided seeding of the inputs to the amplifier using the truncated-Wigner approximation. We find that single-sided seeding degrades the performance of the interferometer exactly at the phase the unseeded interferometer should operate the best. Double-sided seeding results in a phase-sensitive amplifier, where the maximal sensitivity is a function of the phase relationship between the input states of the amplifier. In both single- and double-sided seeding we find there exists an optimal phase shift that achieves sensitivity beyond the standard quantum limit. Experimentally, we demonstrate a spinor phase-sensitive amplifier using a BEC of $^{23}\mathrm{Na}$ in an optical dipole trap. This configuration could be used as an input to such an interferometer. We are able to control the initial phase of the double-seeded amplifier and demonstrate sensitivity to initial population fractions as small as 0.1%.

arXiv:1807.06676•Physical Review A•Aug 16, 2018•22 citations
Although SU(1,1) interferometry achieves Heisenberg-limited sensitivities, it suffers from one major drawback: Only those particles outcoupled from the pump mode contribute to the phase measurement. Since the number of particles outcoupled to these "side modes" is typically small, this limits the interferometer's absolute sensitivity. We propose an alternative "pumped-up" approach where all the input particles participate in the phase measurement and show how this can be implemented in spinor Bose-Einstein condensates and hybrid atom-light systems-both of which have experimentally realized SU(1,1) interferometry. We demonstrate that pumped-up schemes are capable of surpassing the shot-noise limit with respect to the total number of input particles and are never worse than conventional SU(1,1) interferometry. Finally, we show that pumped-up schemes continue to excel-both absolutely and in comparison to conventional SU(1,1) interferometry-in the presence of particle losses, poor particle-resolution detection, and noise on the relative phase difference between the two side modes. Pumped-up SU(1,1) interferometry therefore pushes the advantages of conventional SU(1,1) interferometry into the regime of high absolute sensitivity, which is a necessary condition for useful quantum-enhanced devices.
Quantum-enhanced precision measurements have emerged as one of the most useful applications of quantum optics. Exploiting quantum states of light and quantum processes, classical measurement limits can be surpassed, leading to improvements in areas including clocks, spectroscopy, magnetometry, and imaging. One measurement where straightforward quantum enhancements are possible is phase sensing with an interferometer. One can inject squeezed vacuum states into the dark port of the beamsplitter in a traditional interferometer to reduce the quantum noise and reach phase sensitivities beyond the shot noise limit. An alternate approach is to replace the beamsplitters of an interferometer with nonlinear parametric amplifiers, which produce nonclassical states of light that can be used to surpass classical performance. This so called SU(1,1) interferometer can theoretically approach sensitivities that scale as 1/n, the Heisenberg limit where n is the interior phase sensing photon number, compared to the shot noise limit of 1/ √ n for a traditional interferometer [1]. I will present our group’s experimental progress in testing a Mach-Zender SU(1,1) interferometer using four-wave mixers (4WMs) in hot Rb atoms as the parametric beamsplitters. The 4WM process generates entangled twin beams which serve as the two arms of the interferometer, and are then recombined in a second 4WM cell, resulting in a phase-sensitive output. We will extend the work done on this interferometer [2, 3] by performing a detailed analysis of the output signal to noise through homodyne measurements, and will attempt to observe the better-than-shot-noise scaling of the sensitivity. We will also consider the various difficulties of this optical interferometer such as the susceptibility to loss and imperfect mode-matching within the interferometer. Our group is also considering an analogous SU(1,1) interferometer in a cold atom system. Collisions in a spinor Bose-Einstein condensate of sodium atoms give rise to a 4WM process that produces spin states of the atoms which are entangled in atom number. These interactions can be controlled to set up an SU(1,1) atom interferometer, where the relevant measurements are now atomic population differences rather than photon intensities. These enhancements can lead to drastic improvements in atomic spin interferometry [3, 4].
A major challenge of the phase estimation problem is the engineering of high-intensity entangled probe states. The goal is to significantly enhance above the shot-noise limit the sensitivity of two-mode interferometers. Here we show that this can be achieved by squeezing in input, and then measuring in output, the population fluctuations of a single mode. The second input mode can be left as an arbitrary nonvacuum (e.g., a bright coherent) state. This two-mode state belongs to a novel class of particle-entangled states which are not spin squeezed. Already a 2.4 db gain above shot noise can be obtained when just a single-particle Fock state is injected into the empty input port of a classical interferometer configuration. Higher gains, up to the Heisenberg limit, can be reached with squeezed states of a larger number of particles. We finally study the robustness of this protocol with respect to detection noise.
In nondegenerate SU(1,1) interferometers, beam splitters are replaced by two-mode squeezers, enabling sub-shot-noise sensitivity without input squeezing and robustness to detection losses by quantum entanglement. We propose a hybrid implementation in optomechanics where one "arm" is a mechanical mode undergoing two consecutive, mode-matched interactions with a traveling optical field (constituting the other arm). Such engineered interactions allow for sub-shot-noise phase detection even in the presence of mechanical thermal noise and optical losses, advancing precision interferometry in hybrid systems.
We study the effect of losses on the phase sensitivity of the SU(1,1) interferometer for different configurations. We find that this type of interferometer is robust against losses that result from an inefficient detection system. This type of loss only introduces an overall prefactor to the sensitivity but does not change the 1/n1/n1/n scaling, where nnn is the average number of particles inside the interferometer, characteristic of the Heisenberg limit. In addition, we show that under some conditions the SU(1,1) interferometer with coherent state inputs is also robust against internal losses. These results show that the SU(1,1) interferometer is a viable candidate for experimentally reaching the Heisenberg limit with current technology. Possible implementations of this interferometer using four-wave mixing in atomic vapors or an atom interferometer in a spinor Bose-Einstein condensate are compared.
The SU(1,1) interferometer was originally conceived as a Mach-Zehnder interferometer with the beam splitters replaced by parametric amplifiers. The parametric amplifiers produce states with correlations that result in enhanced phase sensitivity. F=1F=1F=1 spinor Bose-Einstein condensates (BECs) can serve as the parametric amplifiers for an atomic version of such an interferometer by collisionally producing entangled pairs of $|F=1,m=\ifmmode\pm\else\textpm\fi{}1\ensuremath{\rangle}$ atoms. We simulate the effect of single- and double-sided seeding of the inputs to the amplifier using the truncated-Wigner approximation. We find that single-sided seeding degrades the performance of the interferometer exactly at the phase the unseeded interferometer should operate the best. Double-sided seeding results in a phase-sensitive amplifier, where the maximal sensitivity is a function of the phase relationship between the input states of the amplifier. In both single- and double-sided seeding we find there exists an optimal phase shift that achieves sensitivity beyond the standard quantum limit. Experimentally, we demonstrate a spinor phase-sensitive amplifier using a BEC of 23Na^{23}\mathrm{Na}23Na in an optical dipole trap. This configuration could be used as an input to such an interferometer. We are able to control the initial phase of the double-seeded amplifier and demonstrate sensitivity to initial population fractions as small as 0.1%.