Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1709.01697

An application of the measurement of expectation values for the photon annihilation and creation operators

Kouji Nakamura, Masa‐Katsu Fujimoto

Published Sep 6, 2017• 2 citations
arXivHTMLPDF

Abstract

Motivated by the readout scheme in interferometric gravitational-wave detectors, we consider the device which measures the expectation value of the photon annihilation and creation operators for output optical field from the main interferometer. As the result, the eight-port homodyne detection is rediscovered as such a device. We evaluate the noise spectral density in this measurement. We also briefly discuss on the application of our results to the readout scheme of gravitational-wave detectors. We call this measurement scheme to measure these expectation values as "double balanced homodyne detection."

DOI
10.48550/arxiv.1709.01697

Related papers

Double balanced homodyne detection

Kouji Nakamura, Masa‐Katsu Fujimoto

In the context of the readout scheme for gravitational-wave detectors, the "double balanced homodyne detection" proposed in [K.~Nakamura and M.-K.~Fujimoto, arXiv:1709.01697.] is discussed in detail. This double balanced homodyne detection enables us to measure the expectation values of the photon creation and annihilation operators. Although it has been said that the operator $\hat{b}_θ:=\cosθ\hat{b}_{1}+\sinθ\hat{b}_{2}$ can be measured through the homodyne detection in literature, we first show that the expectation value of the operator $\hat{b}_θ$ cannot be measured as the linear combination of the upper- and lower-sidebands from the output of the balanced homodyne detection. Here, the operators $\hat{b}_{1}$ and $\hat{b}_{2}$ are the amplitude and phase quadrature in the two-photon formulation, respectively. On the other hand, it is shown that the above double balanced homodyne detection enables us to measure the expectation value of the operator $\hat{b}_θ$ if we can appropriately prepare the complex amplitude of the coherent state from the local oscillator. It is also shown that the interferometer set up of the eight-port homodyne detection realizes our idea of the double balanced homodyne detection. We also evaluate the noise-spectral density of the gravitational-wave detectors when our double balanced homodyne detection is applied as their readout scheme. Some requirements for the coherent state from the local oscillator to realize the double balanced homodyne detection are also discussed.

arXiv:1711.03713•Nov 10, 2017•3 citations

Quantum noise and vacuum fluctuations in balanced homodyne detections through ideal multi-mode detectors

Kouji Nakamura

Abstract The balanced homodyne detection as a readout scheme of gravitational-wave detectors is carefully examined from the quantum field theoretical point of view. The readout scheme in gravitational-wave detectors specifies the directly measured quantum operator in the detection. This specification is necessary when we apply the recently developed quantum measurement theory to gravitational-wave detections. We examine the two models of measurement. One is the model in which the directly measured quantum operator at the photodetector is Glauber’s photon number operator, and the other is the model in which the power operator of the optical field is directly measured. These two are regarded as ideal models of photodetectors. We first show these two models yield the same expectation value of the measurement. Since there is consensus in the gravitational-wave community that vacuum fluctuations contribute to the noises in the detectors, we also clarify the contributions of vacuum fluctuations to the quantum noise spectral density without using the two-photon formulation which is used in the gravitational-wave community. We found that the conventional noise spectral density in the two-photon formulation includes vacuum fluctuations from the main interferometer but does not include those from the local oscillator. Although the contribution of vacuum fluctuations from the local oscillator theoretically yields the difference between the above two models in the noise spectral densities, this difference is negligible in realistic situations.

arXiv:2107.05614•Progress of Theoretical and Experimental Physics•Sep 6, 2021•2 citations

Vacuum fluctuations and balanced homodyne detection through ideal multi-mode photon number or power counting detectors

Kouji Nakamura

The balanced homodyne detection as a readout scheme of gravitational-wave detectors is carefully examined, which specifies the directly measured quantum operator in the detection. This specification is necessary to apply the quantum measurement theory to gravitational-wave detections. We clarify the contribution of vacuum fluctuations to the noise spectral density without using the two-photon formulation. We found that the noise spectral density in the two-photon formulation includes vacuum fluctuations from the main interferometer but does not includes those from the local oscillator which depends on the directly measured operators.

arXiv:2101.11838•Jan 28, 2021•0 citations

Input spectrum for heterodyne detection in advanced gravitational wave detectors without non-stationary shot-noise

P. T. Beyersdorf

Future interferometric gravitational wave detectors will make use of the coupling between shot noise and radiation pressure noise that produces a squeezed output for the quantum noise at the dark-port of the interferometer allowing these interferometers to operate with a sensitivity that exceeds the standard quantum limit at certain frequencies. The ability of the detector to take advantage of this squeezed output state depends in part on the readout system used. With the phase modulated laser input planned for these interferometers the quantum-noise limited sensitivity is slightly better when homodyne (rather than heterodyne) detection is used. We show that by modifying the laser input spectrum for these interferometers, readout with heterodyne detection can be made to have the same quantum-noise limited sensitivity as readout with homodyne detection.

arXiv:gr-qc/0609113•Sep 25, 2006•0 citations

The use of squeezed states and balanced homodyne for detecting gravitational waves

Y. Ben-Aryeh

The possibility of using squeezed states and balanced homodyne detection of gravitational waves is discussed. It is shown that the quantum noise due to high laser intensities in Michelson interferometer for gravitational waves detection can be reduced by sending squeezed vacuum states to the 'dark' port of the interferometer. The present analysis describes photon statistics measurements effects related to quadrature balanced homodyne detection showing the advantage of using this scheme for detecting gravitational waves.

arXiv:1010.0848•Oct 5, 2010•0 citations

Local-oscillator noise coupling in balanced homodyne readout for advanced gravitational wave detectors

S. Steinlechner, B. Barr, A. S. Bell +13 more

The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum backaction noise. Several backaction evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature space of the output light field, balanced homodyne detection is generally expected to replace the currently used DC readout. Up to now, little investigation has been undertaken into how balanced homodyne detection can be successfully transferred from its ubiquitous application in tabletop quantum optics experiments to large-scale interferometers with suspended optics. Here we derive implementation requirements with respect to local-oscillator noise couplings and highlight potential issues with the example of the Glasgow Sagnac Speed Meter experiment, as well as for a future upgrade to the Advanced LIGO detectors.

arXiv:1506.07308•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Oct 20, 2015•23 citations
Motivated by the readout scheme in interferometric gravitational-wave detectors, we consider the device which measures the expectation value of the photon annihilation and creation operators for output optical field from the main interferometer. As the result, the eight-port homodyne detection is rediscovered as such a device. We evaluate the noise spectral density in this measurement. We also briefly discuss on the application of our results to the readout scheme of gravitational-wave detectors. We call this measurement scheme to measure these expectation values as "double balanced homodyne detection."
In the context of the readout scheme for gravitational-wave detectors, the "double balanced homodyne detection" proposed in [K.~Nakamura and M.-K.~Fujimoto, arXiv:1709.01697.] is discussed in detail. This double balanced homodyne detection enables us to measure the expectation values of the photon creation and annihilation operators. Although it has been said that the operator b^θ:=cos⁡θb^1+sin⁡θb^2\hat{b}_θ:=\cosθ\hat{b}_{1}+\sinθ\hat{b}_{2}b^θ​:=cosθb^1​+sinθb^2​ can be measured through the homodyne detection in literature, we first show that the expectation value of the operator b^θ\hat{b}_θb^θ​ cannot be measured as the linear combination of the upper- and lower-sidebands from the output of the balanced homodyne detection. Here, the operators b^1\hat{b}_{1}b^1​ and b^2\hat{b}_{2}b^2​ are the amplitude and phase quadrature in the two-photon formulation, respectively. On the other hand, it is shown that the above double balanced homodyne detection enables us to measure the expectation value of the operator b^θ\hat{b}_θb^θ​ if we can appropriately prepare the complex amplitude of the coherent state from the local oscillator. It is also shown that the interferometer set up of the eight-port homodyne detection realizes our idea of the double balanced homodyne detection. We also evaluate the noise-spectral density of the gravitational-wave detectors when our double balanced homodyne detection is applied as their readout scheme. Some requirements for the coherent state from the local oscillator to realize the double balanced homodyne detection are also discussed.
Abstract The balanced homodyne detection as a readout scheme of gravitational-wave detectors is carefully examined from the quantum field theoretical point of view. The readout scheme in gravitational-wave detectors specifies the directly measured quantum operator in the detection. This specification is necessary when we apply the recently developed quantum measurement theory to gravitational-wave detections. We examine the two models of measurement. One is the model in which the directly measured quantum operator at the photodetector is Glauber’s photon number operator, and the other is the model in which the power operator of the optical field is directly measured. These two are regarded as ideal models of photodetectors. We first show these two models yield the same expectation value of the measurement. Since there is consensus in the gravitational-wave community that vacuum fluctuations contribute to the noises in the detectors, we also clarify the contributions of vacuum fluctuations to the quantum noise spectral density without using the two-photon formulation which is used in the gravitational-wave community. We found that the conventional noise spectral density in the two-photon formulation includes vacuum fluctuations from the main interferometer but does not include those from the local oscillator. Although the contribution of vacuum fluctuations from the local oscillator theoretically yields the difference between the above two models in the noise spectral densities, this difference is negligible in realistic situations.
The balanced homodyne detection as a readout scheme of gravitational-wave detectors is carefully examined, which specifies the directly measured quantum operator in the detection. This specification is necessary to apply the quantum measurement theory to gravitational-wave detections. We clarify the contribution of vacuum fluctuations to the noise spectral density without using the two-photon formulation. We found that the noise spectral density in the two-photon formulation includes vacuum fluctuations from the main interferometer but does not includes those from the local oscillator which depends on the directly measured operators.
Future interferometric gravitational wave detectors will make use of the coupling between shot noise and radiation pressure noise that produces a squeezed output for the quantum noise at the dark-port of the interferometer allowing these interferometers to operate with a sensitivity that exceeds the standard quantum limit at certain frequencies. The ability of the detector to take advantage of this squeezed output state depends in part on the readout system used. With the phase modulated laser input planned for these interferometers the quantum-noise limited sensitivity is slightly better when homodyne (rather than heterodyne) detection is used. We show that by modifying the laser input spectrum for these interferometers, readout with heterodyne detection can be made to have the same quantum-noise limited sensitivity as readout with homodyne detection.
The possibility of using squeezed states and balanced homodyne detection of gravitational waves is discussed. It is shown that the quantum noise due to high laser intensities in Michelson interferometer for gravitational waves detection can be reduced by sending squeezed vacuum states to the 'dark' port of the interferometer. The present analysis describes photon statistics measurements effects related to quadrature balanced homodyne detection showing the advantage of using this scheme for detecting gravitational waves.
The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum backaction noise. Several backaction evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature space of the output light field, balanced homodyne detection is generally expected to replace the currently used DC readout. Up to now, little investigation has been undertaken into how balanced homodyne detection can be successfully transferred from its ubiquitous application in tabletop quantum optics experiments to large-scale interferometers with suspended optics. Here we derive implementation requirements with respect to local-oscillator noise couplings and highlight potential issues with the example of the Glasgow Sagnac Speed Meter experiment, as well as for a future upgrade to the Advanced LIGO detectors.