Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1604.07692 · Physical Review Letters

Evading Vacuum Noise: Wigner Projections or Husimi Samples?

C. R. Müller, Christian Peuntinger, Thomas Dirmeier, Imran Khan, Ulrich Vogl, Christoph Marquardt, Gerd Leuchs, Luis Lorenzo Sánchez-Soto, Yong Siah Teo, Z. Hradil, Jaroslav Řeháček

Published Aug 11, 2016• 25 citations
arXivHTMLPDF

Abstract

The accuracy in determining the quantum state of a system depends on the type of measurement performed. Homodyne and heterodyne detection are the two main schemes in continuous-variable quantum information. The former leads to a direct reconstruction of the Wigner function of the state, whereas the latter samples its Husimi Q function. We experimentally demonstrate that heterodyne detection outperforms homodyne detection for almost all Gaussian states, the details of which depend on the squeezing strength and thermal noise.

DOI
10.1103/physrevlett.117.070801

Related papers

Overcoming Vacuum Noise: The Unforeseen Benefits of Quantum Heterodyne Detection

C. R. Müller, Christian Peuntinger, Thomas Dirmeier +8 more

Homodyne tomography and heterodyne detection are principal measurement schemes in continuous-variable quantum information and provide different accuracies in determining the quantum state of a system. The former allows for a tomographic reconstruction of the Wigner function of the state, whereas the latter directly samples its Husimi Q-function. We experimentally demonstrate that contrary to a common belief, heterodyne detection outperforms homodyne tomography for almost all Gaussian states.

Frontiers in Optics•Jan 1, 2016•0 citations

Homodyne versus heterodyne detection for classifying families of optical quantum states from finite records of detection events

Franciszek Grzywa, Sebastian Dolata, Karol Bartkiewicz

Neural networks can identify an optical quantum state from an image of its phase-space function, but a real measurement gives a finite record of $N$ detection events. Heterodyne detection samples the Husimi $Q$ function directly, whereas homodyne detection gives the Wigner function only after a reconstruction from several phases. We ask which scheme better identifies one of seven families of states, including Gottesman-Kitaev-Preskill (GKP) states, under loss, dephasing and Gaussian noise. We simulate finite records on identical states for two sets of families, one with equal mean photon number and one built from the code of Ahmed et al. For convolutional networks, heterodyne detection outperforms homodyne detection with filtered back-projection by 14.1 percentage points at $N=100$ events and 20% dephasing in the first set (adjusted $p=0.003$ over $24$ cells across training runs), and it depends on the number of phases and on the reconstruction. At $N=10^3$ and $10^4$ no difference is significant, but the intervals are wide. At $N=100$, a homodyne network without reconstruction does not differ significantly from heterodyne detection in the first set and is nominally worse in the second. Near thermal states we show to leading order that heterodyne detection damps phase-space structure of order $n$ exponentially, whereas homodyne detection shares unit weight among $n+1$ angular components, a local result that does not explain the finite-record differences. Experimental records of a GKP state, photon-subtracted squeezed states and one mode of an Einstein-Podolsky-Rosen source are classified like simulated ones, but these low-power tests probe our counting-noise model, not the seven-class accuracy. A likelihood-ratio observer shows no such gap at $N=100$, so our evidence concerns a reconstruction-based pipeline, not homodyne detection in general.

quant-pharXiv:2610.38671•Oct 30, 2026•0 citations

Witnessing quantum squeezing with binary homodyne detection

Christian R. Muller, Kaushik Parasuram Seshadreesan, Christian Peuntinger +2 more

Homodyne detection is a typical continuous-variable measurement scheme, ubiquitously used in quantum optics and quantum information. A conventional homodyne detector performs a projective measurement onto a quadrature of the electromagnetic field mode, thus yielding a continuously distributed measurement outcome. The outcome distribution is the marginal of the Wigner function of the state. Homodyne detection also forms the basis of heterodyne, or “dual homodyne” detection, which corresponds to measuring the Q function of the state.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

Comparing Homodyne and Heterodyne Tomography of Quantum States of Light

Rhea P. Fernandes, Andrew J. Pizzimenti, Christos N. Gagatsos +1 more

Non-Gaussian quantum states are critical resources in photonic quantum information processing, rendering their generation and characterization of increasing importance in quantum optics. In this work, we theoretically and numerically analyze the relative efficiency of homodyne versus heterodyne measurements for reconstructing non-Gaussian states, a major outstanding question in continuous-variable tomography. Combining a Fisher information-based formalism with simulated experiments, we find homodyne tomography to outperform heterodyne measurements for all non-Gaussian states tested, although the separation between the two modalities proves significantly narrower than suggested by the asymptotic Cramer-Rao lower bound. Our results should find use for optimizing measurement strategies in practical continuous-variable quantum systems.

quant-pharXiv:2512.17031•Dec 22, 2025•0 citations

Engineering and certification of multimode non Gaussian states of light

Niels Tripier-Mondancin, Ganaël Roeland, Yann Bouchereau +5 more

We use double homodyne detection to sample the Q-Husimi function of a photon-subtracted mutlimode squeezed vacuum state. Thereafter, we perform a fidelity estimation protocol to certify the Wigner negativity and stellar rank of the generated state.

Quantum 2.0 Conference and Exhibition•Jan 1, 2024•1 citation

Estimation of the Wigner distribution of single-mode Gaussian states: A comparative study

Chandan Kumar, Arvind

In this work, we consider the estimation of single-mode Gaussian states using four different measurement schemes, namely, (1) homodyne measurement, (2) heterodyne measurement, (3) sequential measurement scheme, and (4) the Arthurs-Kelly measurement scheme, with a view to compare their relative performance. To this end, we work in the phase space formalism, specifically at the covariance matrix level, which provides an elegant and intuitive way to explicitly carry out the involved calculations. We show that the optimal performance of the Arthurs-Kelly and sequential measurement schemes is equal to the heterodyne measurement. While the heterodyne measurement outperforms the homodyne measurement in the mean estimation of squeezed state ensembles, the homodyne measurement outperforms the heterodyne measurement for variance estimation of squeezed state ensembles up to a certain range of the squeezing parameter. We then modify the Hamiltonian in the Arthurs-Kelly measurement scheme, such that the two meters can have correlations and show that the optimal performance is achieved when the meters are uncorrelated. We expect that these results will be useful in various quantum information and quantum communication protocols.

arXiv:2109.13674•Physical Review A•Apr 12, 2022•2 citations
The accuracy in determining the quantum state of a system depends on the type of measurement performed. Homodyne and heterodyne detection are the two main schemes in continuous-variable quantum information. The former leads to a direct reconstruction of the Wigner function of the state, whereas the latter samples its Husimi Q function. We experimentally demonstrate that heterodyne detection outperforms homodyne detection for almost all Gaussian states, the details of which depend on the squeezing strength and thermal noise.
Neural networks can identify an optical quantum state from an image of its phase-space function, but a real measurement gives a finite record of NNN detection events. Heterodyne detection samples the Husimi QQQ function directly, whereas homodyne detection gives the Wigner function only after a reconstruction from several phases. We ask which scheme better identifies one of seven families of states, including Gottesman-Kitaev-Preskill (GKP) states, under loss, dephasing and Gaussian noise. We simulate finite records on identical states for two sets of families, one with equal mean photon number and one built from the code of Ahmed et al. For convolutional networks, heterodyne detection outperforms homodyne detection with filtered back-projection by 14.1 percentage points at N=100N=100N=100 events and 20% dephasing in the first set (adjusted p=0.003p=0.003p=0.003 over 242424 cells across training runs), and it depends on the number of phases and on the reconstruction. At N=103N=10^3N=103 and 10410^4104 no difference is significant, but the intervals are wide. At N=100N=100N=100, a homodyne network without reconstruction does not differ significantly from heterodyne detection in the first set and is nominally worse in the second. Near thermal states we show to leading order that heterodyne detection damps phase-space structure of order nnn exponentially, whereas homodyne detection shares unit weight among n+1n+1n+1 angular components, a local result that does not explain the finite-record differences. Experimental records of a GKP state, photon-subtracted squeezed states and one mode of an Einstein-Podolsky-Rosen source are classified like simulated ones, but these low-power tests probe our counting-noise model, not the seven-class accuracy. A likelihood-ratio observer shows no such gap at N=100N=100N=100, so our evidence concerns a reconstruction-based pipeline, not homodyne detection in general.
Homodyne detection is a typical continuous-variable measurement scheme, ubiquitously used in quantum optics and quantum information. A conventional homodyne detector performs a projective measurement onto a quadrature of the electromagnetic field mode, thus yielding a continuously distributed measurement outcome. The outcome distribution is the marginal of the Wigner function of the state. Homodyne detection also forms the basis of heterodyne, or “dual homodyne” detection, which corresponds to measuring the Q function of the state.
Non-Gaussian quantum states are critical resources in photonic quantum information processing, rendering their generation and characterization of increasing importance in quantum optics. In this work, we theoretically and numerically analyze the relative efficiency of homodyne versus heterodyne measurements for reconstructing non-Gaussian states, a major outstanding question in continuous-variable tomography. Combining a Fisher information-based formalism with simulated experiments, we find homodyne tomography to outperform heterodyne measurements for all non-Gaussian states tested, although the separation between the two modalities proves significantly narrower than suggested by the asymptotic Cramer-Rao lower bound. Our results should find use for optimizing measurement strategies in practical continuous-variable quantum systems.
In this work, we consider the estimation of single-mode Gaussian states using four different measurement schemes, namely, (1) homodyne measurement, (2) heterodyne measurement, (3) sequential measurement scheme, and (4) the Arthurs-Kelly measurement scheme, with a view to compare their relative performance. To this end, we work in the phase space formalism, specifically at the covariance matrix level, which provides an elegant and intuitive way to explicitly carry out the involved calculations. We show that the optimal performance of the Arthurs-Kelly and sequential measurement schemes is equal to the heterodyne measurement. While the heterodyne measurement outperforms the homodyne measurement in the mean estimation of squeezed state ensembles, the homodyne measurement outperforms the heterodyne measurement for variance estimation of squeezed state ensembles up to a certain range of the squeezing parameter. We then modify the Hamiltonian in the Arthurs-Kelly measurement scheme, such that the two meters can have correlations and show that the optimal performance is achieved when the meters are uncorrelated. We expect that these results will be useful in various quantum information and quantum communication protocols.