arXiv:1310.8333 · Applied Physics B

Sub-micron positioning of trapped ions with respect to the absolute center of a standing-wave cavity field

Rasmus B. Linnet, Ian D. Leroux, Aurélien Dantan, Michael Drewsen

Published Oct 8, 2013• 6 citations
arXivHTMLPDF
DOI
10.1007/s00340-013-5666-0

Related papers

Sub-wavelength resolution of optical fields probed by single atoms

Jürgen Eschner

The paper summarizes on the results of several experiments on single trapped ions which have been used to map optical fields. In these experiments, the ion was placed either in front of a (distant) mirror or in an optical cavity. Sub-wavelength resolution is achieved because the position of the ion relative to the mirror(s) is well-controlled and the ion's spatial wavefunction is confined to a region much smaller than the optical wavelength (400 to 800 nm). This strong localization is due to the trapping potential of a Paul-type ion trap, and laser cooling. In the three experiments the ions were Doppler-cooled, and a resolution between about 10 and 50 nm was achieved. With this resolution, the spatial variation of an optical standing-wave field was detected by shifting the single ion through the field structure.

European Quantum Electronics Conference (EQEC)•Jan 1, 2003•0 citations

Precision measurements in ion traps using slowly moving standing waves

A. Walther, U. Poschinger, K. Singer +1 more

arXiv:1105.1710•Applied Physics B•Oct 10, 2011•11 citations

Theoretical and numerical analysis of the positions of cold trapped ions

Todd P. Meyrath, Daniel F. V. James

APS•May 1, 1998•0 citations

Deterministic ion-photon interaction in a cavity

Matthias Keller, Gerhard R. Guthöhrlein, Birgit Lange +3 more

Summary form only given. In a recent experiment, we have investigated the interaction between a single /sup 40/Ca/sup +/-ion stored in a radio-frequency trap and the field of an optical cavity. One mode of the cavity was tuned to the S/sub 1/2/ to P/sub 1/2/ transition of singly ionized calcium at a wavelength of /spl lambda/ = 397 nm. Using laser Doppler cooling in conjunction with the strong confinement of the ion in an effective harmonic potential (frequency 1.1 MHz), the extension of the ion's wave packet was reduced to 60 nm, corresponding to /spl lambda//7, in the direction of the cavity axis. The position of the ion in the cavity was determined by observing the fluorescent light emitted by the ion after excitation in the cavity field. A large fluorescent rate indicated a position of high intracavity intensity. An image of the standing wave pattern obtained in this way is shown. Note that throughout the measurement the ion remains stationary and the cavity is moved to scan the relative position of ion and field.

Quantum Electronics and Laser Science Conference•Jun 25, 2003•0 citations

Theoretical and numerical studies of the positions of cold trapped ions

Todd P. Meyrath, Daniel F. V. James

Physics Letters A•Mar 1, 1998•11 citations

Laser addressing unit for a 50 Qbit ion trap in quantum computing

Erik Beckert, Bernd Höfer, Marcus Babin +2 more

A laser adressing unit at 729 nm for up to 10 Ca40+ ions in a 1D-array was developed, focusing down to ca. 1 micron FWHM at a variable pitch of a few microns and allowing for an individual manipulation of each ion arounds its centered position at lowest cross-talk between neighbouring channels. The optical engine comprises of a wave-guide for defining the pitch between the different channels, moveable steering prisms in a telecentric setup and a final common objective to focus onto the ion trap within a vacuum chamber. This unit was now scaled up towards 50 ions, by placing and aligning several of the units precisely with respect to each other, still using the same high performant objective.

Quantum Computing, Communication, and Simulation•Mar 9, 2022•0 citations
The paper summarizes on the results of several experiments on single trapped ions which have been used to map optical fields. In these experiments, the ion was placed either in front of a (distant) mirror or in an optical cavity. Sub-wavelength resolution is achieved because the position of the ion relative to the mirror(s) is well-controlled and the ion's spatial wavefunction is confined to a region much smaller than the optical wavelength (400 to 800 nm). This strong localization is due to the trapping potential of a Paul-type ion trap, and laser cooling. In the three experiments the ions were Doppler-cooled, and a resolution between about 10 and 50 nm was achieved. With this resolution, the spatial variation of an optical standing-wave field was detected by shifting the single ion through the field structure.
Summary form only given. In a recent experiment, we have investigated the interaction between a single /sup 40/Ca/sup +/-ion stored in a radio-frequency trap and the field of an optical cavity. One mode of the cavity was tuned to the S/sub 1/2/ to P/sub 1/2/ transition of singly ionized calcium at a wavelength of /spl lambda/ = 397 nm. Using laser Doppler cooling in conjunction with the strong confinement of the ion in an effective harmonic potential (frequency 1.1 MHz), the extension of the ion's wave packet was reduced to 60 nm, corresponding to /spl lambda//7, in the direction of the cavity axis. The position of the ion in the cavity was determined by observing the fluorescent light emitted by the ion after excitation in the cavity field. A large fluorescent rate indicated a position of high intracavity intensity. An image of the standing wave pattern obtained in this way is shown. Note that throughout the measurement the ion remains stationary and the cavity is moved to scan the relative position of ion and field.
A laser adressing unit at 729 nm for up to 10 Ca40+ ions in a 1D-array was developed, focusing down to ca. 1 micron FWHM at a variable pitch of a few microns and allowing for an individual manipulation of each ion arounds its centered position at lowest cross-talk between neighbouring channels. The optical engine comprises of a wave-guide for defining the pitch between the different channels, moveable steering prisms in a telecentric setup and a final common objective to focus onto the ion trap within a vacuum chamber. This unit was now scaled up towards 50 ions, by placing and aligning several of the units precisely with respect to each other, still using the same high performant objective.