arXiv:1310.4297 · Nature Photonics

Enhanced two-photon excited fluorescence from imaging agents using true thermal light

Andreas Jechow, Michael Seefeldt, Henning Kurzke, Axel Heuer, Ralf Menzel

Published Oct 5, 2013• 84 citations
arXivHTMLPDF
DOI
10.1038/nphoton.2013.271

Related papers

Enhancing two-photon excited fluorescence by using thermal light

Andreas Jechow, Michael Seefeldt, Henning Kurzke +2 more

Two-photon excited fluorescence (TPEF) has become a standard technique in modern microscopy but it is still affected by photo-damage of the probe owed to high excitation intensities. This work reports on utilizing the photon bunching effect in thermal light to enhance the efficiency of TPEF under continuous wave excitation. A super-luminescence diode (SLD) was used as thermal light source and compared it to coherent excitation from a DFB diode laser emitting at the same wavelength. The degree of second order coherence g(2)of both sources was measured. The SLD showed photon bunching with g(2)= 1.90±0.2 as expected for thermal light, while the DFB diode laser emitted coherent light exhibiting no photon bunching at g(2)= 1.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2013•0 citations

Two-photon resonance fluorescence

Constantine Mavroyannis

Optics Communications•Sep 1, 1978•25 citations

Two-Photon Resonance Fluorescence

T. H. Cheung

Chinese Journal of Physics•Feb 1, 1983•0 citations

Quantum Light-Enhanced Two-Photon Imaging of Breast Cancer Cells

Oleg P. Varnavski, Carolyn E. Gunthardt, Aasia O. Rehman +2 more

Correct biological interpretation from cell imaging can be achieved only if the observed phenomena proceed with negligible perturbation from the imaging system. Herein, we demonstrate microscopic images of breast cancer cells created by the fluorescence selectively excited in the process of entangled two-photon absorption in a scanning microscope at an excitation intensity orders of magnitude lower than that used for classical two-photon microscopy. Quantum enhanced entangled two-photon microscopy has shown cell imaging capabilities at an unprecedented low excitation intensity of ∼3.6 × 10 7 photons/s, which is a million times lower than the excitation level for the classical two-photon fluorescence image obtained in the same microscope. The extremely low light probe intensity demonstrated in entangled two-photon microscopy is of critical importance to minimize photobleaching during repetitive imaging and damage to cells in live-cell applications. This technology opens new avenues in cell investigations with light microscopy, such as enhanced selectivity and time–frequency resolution.

The Journal of Physical Chemistry Letters•Mar 23, 2022•43 citations

Two-atom two-photon resonance fluorescence

Constantine Mavroyannis

Optics Communications•Dec 1, 1978•14 citations

Impact of Photon Statistics on Two-Photon Excited Fluorescence

Henning Kurzke, Andreas Jechow, Michael Seefeldt +3 more

We report on utilizing the photon bunching effect in thermal light to enhance the efficiency of Two-Photon Excited Fluorescence (TPEF) under continuous wave illumination. This has potential applications in microscopy.

•Jan 1, 2014•0 citations
Two-photon excited fluorescence (TPEF) has become a standard technique in modern microscopy but it is still affected by photo-damage of the probe owed to high excitation intensities. This work reports on utilizing the photon bunching effect in thermal light to enhance the efficiency of TPEF under continuous wave excitation. A super-luminescence diode (SLD) was used as thermal light source and compared it to coherent excitation from a DFB diode laser emitting at the same wavelength. The degree of second order coherence g(2)of both sources was measured. The SLD showed photon bunching with g(2)= 1.90±0.2 as expected for thermal light, while the DFB diode laser emitted coherent light exhibiting no photon bunching at g(2)= 1.
Correct biological interpretation from cell imaging can be achieved only if the observed phenomena proceed with negligible perturbation from the imaging system. Herein, we demonstrate microscopic images of breast cancer cells created by the fluorescence selectively excited in the process of entangled two-photon absorption in a scanning microscope at an excitation intensity orders of magnitude lower than that used for classical two-photon microscopy. Quantum enhanced entangled two-photon microscopy has shown cell imaging capabilities at an unprecedented low excitation intensity of ∼3.6 × 10 7 photons/s, which is a million times lower than the excitation level for the classical two-photon fluorescence image obtained in the same microscope. The extremely low light probe intensity demonstrated in entangled two-photon microscopy is of critical importance to minimize photobleaching during repetitive imaging and damage to cells in live-cell applications. This technology opens new avenues in cell investigations with light microscopy, such as enhanced selectivity and time–frequency resolution.