Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1302.2852 · Journal of Applied Physics

Readout of superconducting nanowire single-photon detectors at high count rates

Andrew J. Kerman, Danna Rosenberg, R. J. Molnar, Eric A. Dauler

Published Apr 11, 2013• 109 citations
arXivHTMLPDF

Abstract

Superconducting nanowire single-photon detectors are set apart from other photon counting technologies above all else by their extremely high speed, with few-ten-ps timing resolution, and recovery times τR ≲ 10 ns after a detection event. In this work, however, we identify in the conventional electrical readout scheme a nonlinear interaction between the detector and its readout which can make stable, high-efficiency operation impossible at count rates even an order-of-magnitude less than τR−1. We present detailed experimental confirmation of this, and a theoretical model which quantitatively explains our observations. Finally, we describe an improved readout which circumvents this problem, allowing these detectors to be operated stably at high count rates, with a detection efficiency penalty determined purely by their inductive reset time.

DOI
10.1063/1.4799397

Related papers

High-speed and high-efficiency superconducting nanowire single photon detector array

Danna Rosenberg, Andrew J. Kerman, R. J. Molnar +1 more

Superconducting nanowire single photon detectors (SNSPDs) have separately demonstrated high efficiency, low noise, and extremely high speed when detecting single photons. However, achieving all of these simultaneously has been limited by detector subtleties and tradeoffs. Here, we report an SNSPD system with <80 ps timing resolution, kHz noise count rates, and 76% fiber-coupled system detection efficiency in the low-flux limit at 1550 nm. We present a model for determining the detection efficiency penalty due to the detection recovery time, and we validate our method using experimental data obtained at high count rates. We demonstrate improved performance tradeoffs, such as 68% system detection efficiency, including losses due to detector recovery time, when coupled to a Poisson source emitting 100 million photons per second. Our system can provide limited photon number resolution, continuous cryogen-free operation, and scalability to future imaging and GHz-count-rate applications.

Optics Express•Jan 14, 2013•191 citations

Accurately modeling the recovery time of superconducting nanowire single-photon detectors as a function of bias current

Leo Oshiro, Hudson Jones, Timothy M. Rambo +3 more

Superconducting nanowire single-photon detectors (SNSPDs) are an attractive technology for applications which benefit from high-count rate photon detection such as quantum communication protocols, photon-starved classical communications, metrology of single-emitters, and photonic quantum computing. However, at high-count rates, a significant portion of photons may be incident during recovery intervals following prior detection events. After detection, the device efficiency recovers over nanoseconds to tens of nanoseconds before reaching a steadystate value. Therefore, for a given SNSPD bias current setpoint, a single efficiency and recovery time specification may not be sufficient to characterize the performance of a device at high count rates. Here we present and experimentally validate a model of the recovery time as a function of bias current for any given system efficiency. These results may be used to improve analysis of measurements performed using SNSPDs operating in the high count rate regime.

Quantum Computing, Communication, and Simulation•Mar 19, 2025•2 citations

Characterize the Speed of a Photon-Number-Resolving Superconducting Nanowire Detector

Tao Xu, Hao Hao, Xiang Li +8 more

Superconducting series nanowire single-photon detectors (SNDs) have been used for resolving photon numbers. But it can also exhibit a higher counting rate than a single superconducting nanowire single-photon detector (SNSPD), because the serial architecture allows multiple detectors working in parallel and the inductance of each pixel is reduced. In this paper, we found each pixel of the SND could reset fast although the whole detector took a much longer time for recovering. Therefore, the speed of an SND with a large kinetic inductance of 1.25 μH was characterized and compared to a standard SNSPD with the same total inductance. By measuring the detected photon rate over the input photon rate, we obtained a photon counting rate enhancement by 7.5 times. Meanwhile, the timing jitter of the SND was 63 ps at single photon detection regime. Our results show that the series structure and the readout scheme are quite practical in realizing high speed single-photon detectors besides resolving photon numbers.

IEEE photonics journal•Jul 28, 2020•12 citations

Counting rate enhancements in superconducting nanowire single-photon detectors with improved readout circuits

Qingyuan Zhao, Tao Jia, Min Gu +6 more

Counting rates of superconducting nanowire single-photon detectors are usually estimated at hundreds of MHz by their kinetic-inductive reset time. This maximum is also limited by capacitor coupling effects in conventional readout circuits. In this Letter, we design and demonstrate an improved readout circuit that reduces the reset time and removes circuit limits. The counting rate at the 3 dB compression point is increased by four times for a large active area detector. We also discuss nonlinear dependences of the counting rate on the incident continuous-wave optical power and give a numerical model to explain our observations.

Optics Letters•Mar 20, 2014•49 citations

Analysis of the detection response of waveguide-integrated superconducting nanowire single-photon detectors at high count rate

Simone Ferrari, Vadim V. Kovalyuk, Andreas Vetter +5 more

Nanophotonic circuitry and superconducting nanowires have been successfully combined for detecting single photons, propagating in an integrated photonic circuit, with high efficiency and low noise and timing uncertainty. Waveguide-integrated superconducting nanowire single-photon detectors (SNSPDs) can nowadays be engineered to achieve subnanosecond recovery times and can potentially be adopted for applications requiring Gcps count rates. However, particular attention shall be paid to such an extreme count rate regime since artifacts in the detector functionality emerge. In particular, a count-rate dependent detection efficiency has been encountered that can compromise the accuracy of quantum detector tomography experiments. Here, we investigate the response of waveguide-integrated SNSPDs at high photon flux and identify the presence of parasitic currents due to the accumulation of charge in the readout electronics to cause the above-mentioned artifact in the detection efficiency. Our approach allows us to determine the maximum photon count rate at which the detector can be operated without adverse effects. Our findings are particularly important to avoid artifacts when applying SNSPDs for quantum tomography.

Applied Physics Letters•Sep 2, 2019•13 citations

High-speed detection of 1550 nm single photons with superconducting nanowire detectors

Ioana Craiciu, Boris A. Korzh, Andrew D. Beyer +8 more

Superconducting nanowire single-photon detectors are a key technology for quantum information and science due to their high efficiency, low timing jitter, and low dark counts. In this work, we present a detector for single 1550 nm photons with up to 78% detection efficiency, timing jitter below 50 ps FWHM, 158 counts/s dark count rate, as well as a maximum count rate of 1.5 giga-counts/s at 3 dB compression. The PEACOQ detector (Performance-Enhanced Array for Counting Optical Quanta) comprises a linear array of 32 straight superconducting niobium nitride nanowires that span the mode of an optical fiber. This design supports high count rates with minimal penalties for detection efficiency and timing jitter. We show how these trade-offs can be mitigated by implementing independent readout for each nanowire and by using a temporal walk correction technique to reduce count-rate dependent timing jitter. These detectors make quantum communication practical on a 10 GHz clock.

Optica•Dec 20, 2022•73 citations
Superconducting nanowire single-photon detectors are set apart from other photon counting technologies above all else by their extremely high speed, with few-ten-ps timing resolution, and recovery times τR ≲ 10 ns after a detection event. In this work, however, we identify in the conventional electrical readout scheme a nonlinear interaction between the detector and its readout which can make stable, high-efficiency operation impossible at count rates even an order-of-magnitude less than τR−1. We present detailed experimental confirmation of this, and a theoretical model which quantitatively explains our observations. Finally, we describe an improved readout which circumvents this problem, allowing these detectors to be operated stably at high count rates, with a detection efficiency penalty determined purely by their inductive reset time.
Superconducting nanowire single photon detectors (SNSPDs) have separately demonstrated high efficiency, low noise, and extremely high speed when detecting single photons. However, achieving all of these simultaneously has been limited by detector subtleties and tradeoffs. Here, we report an SNSPD system with <80 ps timing resolution, kHz noise count rates, and 76% fiber-coupled system detection efficiency in the low-flux limit at 1550 nm. We present a model for determining the detection efficiency penalty due to the detection recovery time, and we validate our method using experimental data obtained at high count rates. We demonstrate improved performance tradeoffs, such as 68% system detection efficiency, including losses due to detector recovery time, when coupled to a Poisson source emitting 100 million photons per second. Our system can provide limited photon number resolution, continuous cryogen-free operation, and scalability to future imaging and GHz-count-rate applications.
Superconducting nanowire single-photon detectors (SNSPDs) are an attractive technology for applications which benefit from high-count rate photon detection such as quantum communication protocols, photon-starved classical communications, metrology of single-emitters, and photonic quantum computing. However, at high-count rates, a significant portion of photons may be incident during recovery intervals following prior detection events. After detection, the device efficiency recovers over nanoseconds to tens of nanoseconds before reaching a steadystate value. Therefore, for a given SNSPD bias current setpoint, a single efficiency and recovery time specification may not be sufficient to characterize the performance of a device at high count rates. Here we present and experimentally validate a model of the recovery time as a function of bias current for any given system efficiency. These results may be used to improve analysis of measurements performed using SNSPDs operating in the high count rate regime.
Superconducting series nanowire single-photon detectors (SNDs) have been used for resolving photon numbers. But it can also exhibit a higher counting rate than a single superconducting nanowire single-photon detector (SNSPD), because the serial architecture allows multiple detectors working in parallel and the inductance of each pixel is reduced. In this paper, we found each pixel of the SND could reset fast although the whole detector took a much longer time for recovering. Therefore, the speed of an SND with a large kinetic inductance of 1.25 μH was characterized and compared to a standard SNSPD with the same total inductance. By measuring the detected photon rate over the input photon rate, we obtained a photon counting rate enhancement by 7.5 times. Meanwhile, the timing jitter of the SND was 63 ps at single photon detection regime. Our results show that the series structure and the readout scheme are quite practical in realizing high speed single-photon detectors besides resolving photon numbers.
Counting rates of superconducting nanowire single-photon detectors are usually estimated at hundreds of MHz by their kinetic-inductive reset time. This maximum is also limited by capacitor coupling effects in conventional readout circuits. In this Letter, we design and demonstrate an improved readout circuit that reduces the reset time and removes circuit limits. The counting rate at the 3 dB compression point is increased by four times for a large active area detector. We also discuss nonlinear dependences of the counting rate on the incident continuous-wave optical power and give a numerical model to explain our observations.
Nanophotonic circuitry and superconducting nanowires have been successfully combined for detecting single photons, propagating in an integrated photonic circuit, with high efficiency and low noise and timing uncertainty. Waveguide-integrated superconducting nanowire single-photon detectors (SNSPDs) can nowadays be engineered to achieve subnanosecond recovery times and can potentially be adopted for applications requiring Gcps count rates. However, particular attention shall be paid to such an extreme count rate regime since artifacts in the detector functionality emerge. In particular, a count-rate dependent detection efficiency has been encountered that can compromise the accuracy of quantum detector tomography experiments. Here, we investigate the response of waveguide-integrated SNSPDs at high photon flux and identify the presence of parasitic currents due to the accumulation of charge in the readout electronics to cause the above-mentioned artifact in the detection efficiency. Our approach allows us to determine the maximum photon count rate at which the detector can be operated without adverse effects. Our findings are particularly important to avoid artifacts when applying SNSPDs for quantum tomography.
Superconducting nanowire single-photon detectors are a key technology for quantum information and science due to their high efficiency, low timing jitter, and low dark counts. In this work, we present a detector for single 1550 nm photons with up to 78% detection efficiency, timing jitter below 50 ps FWHM, 158 counts/s dark count rate, as well as a maximum count rate of 1.5 giga-counts/s at 3 dB compression. The PEACOQ detector (Performance-Enhanced Array for Counting Optical Quanta) comprises a linear array of 32 straight superconducting niobium nitride nanowires that span the mode of an optical fiber. This design supports high count rates with minimal penalties for detection efficiency and timing jitter. We show how these trade-offs can be mitigated by implementing independent readout for each nanowire and by using a temporal walk correction technique to reduce count-rate dependent timing jitter. These detectors make quantum communication practical on a 10 GHz clock.