Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Counting rate enhancements in superconducting nanowire single-photon detectors with improved readout circuits

Qingyuan Zhao, Tao Jia, Min Gu, Chao Wan, Labao Zhang, Weiwei Xu, Lin Kang, Jian Chen, Peiheng Wu

Published Mar 20, 2014• 49 citations
Publisher

Abstract

Counting rates of superconducting nanowire single-photon detectors are usually estimated at hundreds of MHz by their kinetic-inductive reset time. This maximum is also limited by capacitor coupling effects in conventional readout circuits. In this Letter, we design and demonstrate an improved readout circuit that reduces the reset time and removes circuit limits. The counting rate at the 3 dB compression point is increased by four times for a large active area detector. We also discuss nonlinear dependences of the counting rate on the incident continuous-wave optical power and give a numerical model to explain our observations.

DOI
10.1364/ol.39.001869

Related papers

Improving maximum count rate of superconducting nanowire single-photon detector with small active area using series attenuator

Chaolin Lv, Weijun Zhang, Lixing You +9 more

Maximum count rate is a crucial parameter of superconducting nanowire single-photon detector (SNSPD) for quantum communication and laser communication. However, when increasing the incident photon flux, the SNSPD device with small active area is apt to latch due to the AC coupling of room temperature amplifier in the readout circuit, which limits SNSPD to reach a high count rate. We proposed a simple way by inserting an electrical attenuator in series with small-active area SNSPD to avoid the latching effect, thus improving maximum count rate effectively. The count rate with the system detection efficiency reduced by half increased by 6 times for SNSPD with an active area of Φ15 μm.

AIP Advances•Oct 1, 2018•14 citations

Readout of superconducting nanowire single-photon detectors at high count rates

Andrew J. Kerman, Danna Rosenberg, R. J. Molnar +1 more

Superconducting nanowire single-photon detectors are set apart from other photon counting technologies above all else by their extremely high speed, with few-ten-ps timing resolution, and recovery times τR ≲ 10 ns after a detection event. In this work, however, we identify in the conventional electrical readout scheme a nonlinear interaction between the detector and its readout which can make stable, high-efficiency operation impossible at count rates even an order-of-magnitude less than τR−1. We present detailed experimental confirmation of this, and a theoretical model which quantitatively explains our observations. Finally, we describe an improved readout which circumvents this problem, allowing these detectors to be operated stably at high count rates, with a detection efficiency penalty determined purely by their inductive reset time.

arXiv:1302.2852•Journal of Applied Physics•Apr 11, 2013•109 citations

Practical High-Efficiency SNSPD Balanced High Speed and Low Jitter on Filter Circuit

Changmin Li, Guangzhao Xu, Xingyu Zhang +7 more

Superconducting nanowire single-photon detectors (SNSPDs) are integral to the fields of quantum information and quantum communication, offering high efficiency, low dark count rate, high count rate, and minimal timing jitter. However, a common challenge with SNSPDs is their propensity for latching and nonlinear count rate increase under high incident photon fluxes due to the traditional external readout circuitry. This issue is primarily caused by large dynamic inductance and the ac-coupled effects of the bias and amplifier capacitors. In this study, we carefully selected a commercial SNSPD with an efficiency of over 95%. To address the aforementioned challenges, we implemented a resistor–inductor-type filter structure, which is directly coupled to a low-temperature amplifier, and their operating temperature is 40 K. Experimental results revealed that the enhanced SNSPD readout circuit achieves a count rate that is approximately 3.5 times greater than that of the traditional circuit. Moreover, the timing jitter of the SNSPD was optimized, decreasing by approximately 3.6 times under high incident photon fluxes. These performance enhancements could significantly improve high-speed optical communication and quantum precision measurement.

IEEE Transactions on Applied Superconductivity•Jul 15, 2024•3 citations

Scalable cryogenic readout circuit for a superconducting nanowire single-photon detector system

Clinton Cahall, Daniel J. Gauthier, Jungsang Kim

The superconducting nanowire single-photon detector (SNSPD) is a leading technology for quantum information science applications using photons, and is finding increasing uses in photon-starved classical imaging applications. Critical detector characteristics, such as timing resolution (jitter), reset time, and maximum count rate, are heavily influenced by the readout electronics that sense and amplify the photon detection signal. We describe a readout circuit for SNSPDs using commercial off-the-shelf amplifiers operating at cryogenic temperatures. Our design demonstrates a 35 ps timing resolution and a maximum count rate of over 2 × 107 counts per second, while maintaining <3 mW power consumption per channel, making it suitable for a multichannel readout.

arXiv:1710.04684•Review of Scientific Instruments•Jun 1, 2018•28 citations

Characterize the Speed of a Photon-Number-Resolving Superconducting Nanowire Detector

Tao Xu, Hao Hao, Xiang Li +8 more

Superconducting series nanowire single-photon detectors (SNDs) have been used for resolving photon numbers. But it can also exhibit a higher counting rate than a single superconducting nanowire single-photon detector (SNSPD), because the serial architecture allows multiple detectors working in parallel and the inductance of each pixel is reduced. In this paper, we found each pixel of the SND could reset fast although the whole detector took a much longer time for recovering. Therefore, the speed of an SND with a large kinetic inductance of 1.25 μH was characterized and compared to a standard SNSPD with the same total inductance. By measuring the detected photon rate over the input photon rate, we obtained a photon counting rate enhancement by 7.5 times. Meanwhile, the timing jitter of the SND was 63 ps at single photon detection regime. Our results show that the series structure and the readout scheme are quite practical in realizing high speed single-photon detectors besides resolving photon numbers.

IEEE photonics journal•Jul 28, 2020•12 citations

High speed superconducting nanowire single-photon detector with nine interleaved nanowires

Jia Huang, Weijun Zhang, Lixing You +6 more

Abstract Count rate (CR) is one of the key parameters of superconducting nanowire single-photon detectors (SNSPDs). The practical SNSPDs usually have a CR of a few MHz to a few tens of MHz owing to the large kinetic inductance originating from the long nanowire, which is necessary for effectively coupling the photons. A feasible approach to decrease the kinetic inductance and consequently increase the detection speed is to replace a long single nanowire with multiple individual nanowires in an array. In this study, we report an SNSPD of nine interleaved nanowires with 70% system detection efficiency (SDE) and 200 Hz dark count rate at the low-photon-flux limit of 1550 nm. Owing to the small dead time (<6 ns) of each nanowire, the SNSPD achieved a maximum CR of 0.93 GHz at a photon flux of 1.26 × 10 10 photons s −1 with an SDE of ∼7.4%, and a CR of 200 MHz with an SDE of over 50%. Furthermore, a photon number resolvability of up to nine photons was also demonstrated.

Superconductor Science and Technology•May 1, 2018•37 citations
Counting rates of superconducting nanowire single-photon detectors are usually estimated at hundreds of MHz by their kinetic-inductive reset time. This maximum is also limited by capacitor coupling effects in conventional readout circuits. In this Letter, we design and demonstrate an improved readout circuit that reduces the reset time and removes circuit limits. The counting rate at the 3 dB compression point is increased by four times for a large active area detector. We also discuss nonlinear dependences of the counting rate on the incident continuous-wave optical power and give a numerical model to explain our observations.
Maximum count rate is a crucial parameter of superconducting nanowire single-photon detector (SNSPD) for quantum communication and laser communication. However, when increasing the incident photon flux, the SNSPD device with small active area is apt to latch due to the AC coupling of room temperature amplifier in the readout circuit, which limits SNSPD to reach a high count rate. We proposed a simple way by inserting an electrical attenuator in series with small-active area SNSPD to avoid the latching effect, thus improving maximum count rate effectively. The count rate with the system detection efficiency reduced by half increased by 6 times for SNSPD with an active area of Φ15 μm.
Superconducting nanowire single-photon detectors are set apart from other photon counting technologies above all else by their extremely high speed, with few-ten-ps timing resolution, and recovery times τR ≲ 10 ns after a detection event. In this work, however, we identify in the conventional electrical readout scheme a nonlinear interaction between the detector and its readout which can make stable, high-efficiency operation impossible at count rates even an order-of-magnitude less than τR−1. We present detailed experimental confirmation of this, and a theoretical model which quantitatively explains our observations. Finally, we describe an improved readout which circumvents this problem, allowing these detectors to be operated stably at high count rates, with a detection efficiency penalty determined purely by their inductive reset time.
Superconducting nanowire single-photon detectors (SNSPDs) are integral to the fields of quantum information and quantum communication, offering high efficiency, low dark count rate, high count rate, and minimal timing jitter. However, a common challenge with SNSPDs is their propensity for latching and nonlinear count rate increase under high incident photon fluxes due to the traditional external readout circuitry. This issue is primarily caused by large dynamic inductance and the ac-coupled effects of the bias and amplifier capacitors. In this study, we carefully selected a commercial SNSPD with an efficiency of over 95%. To address the aforementioned challenges, we implemented a resistor–inductor-type filter structure, which is directly coupled to a low-temperature amplifier, and their operating temperature is 40 K. Experimental results revealed that the enhanced SNSPD readout circuit achieves a count rate that is approximately 3.5 times greater than that of the traditional circuit. Moreover, the timing jitter of the SNSPD was optimized, decreasing by approximately 3.6 times under high incident photon fluxes. These performance enhancements could significantly improve high-speed optical communication and quantum precision measurement.
The superconducting nanowire single-photon detector (SNSPD) is a leading technology for quantum information science applications using photons, and is finding increasing uses in photon-starved classical imaging applications. Critical detector characteristics, such as timing resolution (jitter), reset time, and maximum count rate, are heavily influenced by the readout electronics that sense and amplify the photon detection signal. We describe a readout circuit for SNSPDs using commercial off-the-shelf amplifiers operating at cryogenic temperatures. Our design demonstrates a 35 ps timing resolution and a maximum count rate of over 2 × 107 counts per second, while maintaining <3 mW power consumption per channel, making it suitable for a multichannel readout.
Superconducting series nanowire single-photon detectors (SNDs) have been used for resolving photon numbers. But it can also exhibit a higher counting rate than a single superconducting nanowire single-photon detector (SNSPD), because the serial architecture allows multiple detectors working in parallel and the inductance of each pixel is reduced. In this paper, we found each pixel of the SND could reset fast although the whole detector took a much longer time for recovering. Therefore, the speed of an SND with a large kinetic inductance of 1.25 μH was characterized and compared to a standard SNSPD with the same total inductance. By measuring the detected photon rate over the input photon rate, we obtained a photon counting rate enhancement by 7.5 times. Meanwhile, the timing jitter of the SND was 63 ps at single photon detection regime. Our results show that the series structure and the readout scheme are quite practical in realizing high speed single-photon detectors besides resolving photon numbers.
Abstract Count rate (CR) is one of the key parameters of superconducting nanowire single-photon detectors (SNSPDs). The practical SNSPDs usually have a CR of a few MHz to a few tens of MHz owing to the large kinetic inductance originating from the long nanowire, which is necessary for effectively coupling the photons. A feasible approach to decrease the kinetic inductance and consequently increase the detection speed is to replace a long single nanowire with multiple individual nanowires in an array. In this study, we report an SNSPD of nine interleaved nanowires with 70% system detection efficiency (SDE) and 200 Hz dark count rate at the low-photon-flux limit of 1550 nm. Owing to the small dead time (<6 ns) of each nanowire, the SNSPD achieved a maximum CR of 0.93 GHz at a photon flux of 1.26 × 10 10 photons s −1 with an SDE of ∼7.4%, and a CR of 200 MHz with an SDE of over 50%. Furthermore, a photon number resolvability of up to nine photons was also demonstrated.