Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Computing, Communication, and Simulation

Accurately modeling the recovery time of superconducting nanowire single-photon detectors as a function of bias current

Leo Oshiro, Hudson Jones, Timothy M. Rambo, J. Cassada, Stephanie Boyd, Aaron Miller

Published Mar 19, 2025• 2 citations
Publisher

Abstract

Superconducting nanowire single-photon detectors (SNSPDs) are an attractive technology for applications which benefit from high-count rate photon detection such as quantum communication protocols, photon-starved classical communications, metrology of single-emitters, and photonic quantum computing. However, at high-count rates, a significant portion of photons may be incident during recovery intervals following prior detection events. After detection, the device efficiency recovers over nanoseconds to tens of nanoseconds before reaching a steadystate value. Therefore, for a given SNSPD bias current setpoint, a single efficiency and recovery time specification may not be sufficient to characterize the performance of a device at high count rates. Here we present and experimentally validate a model of the recovery time as a function of bias current for any given system efficiency. These results may be used to improve analysis of measurements performed using SNSPDs operating in the high count rate regime.

DOI
10.1117/12.3040258

Related papers

Investigations of afterpulsing and detection efficiency recovery in superconducting nanowire single-photon detectors

Viacheslav Burenkov, He Xu, Bing Qi +2 more

We report on the observation of a non-uniform dark count rate in Superconducting Nanowire Single Photon Detectors (SNSPDs), specifically focusing on an afterpulsing effect present when the SNSPD is operated at a high bias current regime. The afterpulsing exists for real detection events (triggered by input photons) as well as for dark counts (no laser input). In our standard set-up, the afterpulsing is most likely to occur at around 180 ns following a detection event, for both real counts and dark counts. We characterize the afterpulsing behavior and speculate that it is not due to the SNSPD itself but rather the amplifiers used to boost the electrical output signal from the SNSPD. We show that the afterpulsing indeed disappears when we use a different amplifier with a better low frequency response. We also examine the short-lived enhancement of detection efficiency during the recovery of the SNSPD due to temporary perturbation of the bias and grounding conditions.

arXiv:1306.3749•Journal of Applied Physics•Jun 3, 2013•22 citations

Statistical analysis of the temporal single-photon response of superconducting nanowire single photon detection

Y. H. He, Chao-Lin Lü, W.-J. Zhang +5 more

Counting rate is a key parameter of superconducting nanowire single photon detectors (SNSPD) and is determined by the current recovery time of an SNSPD after a detection event. We propose a new method to study the transient detection efficiency (DE) and pulse amplitude during the current recovery process by statistically analyzing the single photon response of an SNSPD under photon illumination with a high repetition rate. The transient DE results match well with the DEs deduced from the static current dependence of DE combined with the waveform of a single-photon detection event. This proves that the static measurement results can be used to analyze the transient current recovery process after a detection event. The results are relevant for understanding the current recovery process of SNSPDs after a detection event and for determining the counting rate of SNSPDs.

arXiv:1506.07919•Jun 25, 2015•0 citations

High-speed and high-efficiency superconducting nanowire single photon detector array

Danna Rosenberg, Andrew J. Kerman, R. J. Molnar +1 more

Superconducting nanowire single photon detectors (SNSPDs) have separately demonstrated high efficiency, low noise, and extremely high speed when detecting single photons. However, achieving all of these simultaneously has been limited by detector subtleties and tradeoffs. Here, we report an SNSPD system with <80 ps timing resolution, kHz noise count rates, and 76% fiber-coupled system detection efficiency in the low-flux limit at 1550 nm. We present a model for determining the detection efficiency penalty due to the detection recovery time, and we validate our method using experimental data obtained at high count rates. We demonstrate improved performance tradeoffs, such as 68% system detection efficiency, including losses due to detector recovery time, when coupled to a Poisson source emitting 100 million photons per second. Our system can provide limited photon number resolution, continuous cryogen-free operation, and scalability to future imaging and GHz-count-rate applications.

Optics Express•Jan 14, 2013•191 citations

Statistical analysis of the temporal single-photon response of superconducting nanowire single photon detection

何宇昊, 吕超林, 张伟君 +5 more

A new method to study the transient detection efficiency(DE) and pulse amplitude of superconducting nanowire single photon detectors(SNSPD) during the current recovery process is proposed — statistically analyzing the single photon response under photon illumination with a high repetition rate.The transient DE results match well with the DEs deduced from the static current dependence of DE combined with the waveform of a single-photon detection event.This proves that static measurement results can be used to analyze the transient current recovery process after a detection event.The results are relevant for understanding the current recovery process of SNSPDs after a detection event and for determining the counting rate of SNSPDs.

中国物理B:英文版•Jan 1, 2015•0 citations

Direct measurement of the recovery time of superconducting nanowire single-photon detectors

Claire Autebert, Gaëtan Gras, Emna Amri +4 more

One of the key properties of single-photon detectors is their recovery time, i.e. the time required for the detector to recover its nominal efficiency. In the case of superconducting nanowire single-photon detectors (SNSPDs), which can feature extremely short recovery times in free-running mode, a precise characterization of this recovery time and its time dynamics is essential for many quantum optics or quantum communication experiments. We introduce a fast and simple method to characterize precisely the recovery time of SNSPDs. It provides full information about the recovery of the efficiency in time for a single or several consecutive detections. We also show how the method can be used to gain insight into the behavior of the bias current inside the nanowire after a detection, which allows predicting the behavior of the detector and its efficiency in any practical experiment using these detectors.

•Jan 1, 2020•21 citations

Direct measurement of the recovery time of superconducting nanowire single-photon detectors

Claire Autebert, Gaëtan Gras, Emna Amri +4 more

One of the key properties of single-photon detectors is their recovery time, i.e., the time required for the detector to recover its nominal efficiency. In the case of superconducting nanowire single-photon detectors (SNSPDs), which can feature extremely short recovery times in free-running mode, a precise characterization of this recovery time and its time dynamics is essential for many quantum optics or quantum communication experiments. We introduce a fast and simple method to characterize precisely the recovery time of SNSPDs. It provides full information about the recovery of the efficiency in time for a single or several consecutive detections. We also show how the method can be used to gain insight into the behavior of the bias current inside the nanowire after a detection, which allows predicting the behavior of the detector and its efficiency in any practical experiment using these detectors.

arXiv:2003.06290•Journal of Applied Physics•Aug 20, 2020•28 citations
Superconducting nanowire single-photon detectors (SNSPDs) are an attractive technology for applications which benefit from high-count rate photon detection such as quantum communication protocols, photon-starved classical communications, metrology of single-emitters, and photonic quantum computing. However, at high-count rates, a significant portion of photons may be incident during recovery intervals following prior detection events. After detection, the device efficiency recovers over nanoseconds to tens of nanoseconds before reaching a steadystate value. Therefore, for a given SNSPD bias current setpoint, a single efficiency and recovery time specification may not be sufficient to characterize the performance of a device at high count rates. Here we present and experimentally validate a model of the recovery time as a function of bias current for any given system efficiency. These results may be used to improve analysis of measurements performed using SNSPDs operating in the high count rate regime.
We report on the observation of a non-uniform dark count rate in Superconducting Nanowire Single Photon Detectors (SNSPDs), specifically focusing on an afterpulsing effect present when the SNSPD is operated at a high bias current regime. The afterpulsing exists for real detection events (triggered by input photons) as well as for dark counts (no laser input). In our standard set-up, the afterpulsing is most likely to occur at around 180 ns following a detection event, for both real counts and dark counts. We characterize the afterpulsing behavior and speculate that it is not due to the SNSPD itself but rather the amplifiers used to boost the electrical output signal from the SNSPD. We show that the afterpulsing indeed disappears when we use a different amplifier with a better low frequency response. We also examine the short-lived enhancement of detection efficiency during the recovery of the SNSPD due to temporary perturbation of the bias and grounding conditions.
Counting rate is a key parameter of superconducting nanowire single photon detectors (SNSPD) and is determined by the current recovery time of an SNSPD after a detection event. We propose a new method to study the transient detection efficiency (DE) and pulse amplitude during the current recovery process by statistically analyzing the single photon response of an SNSPD under photon illumination with a high repetition rate. The transient DE results match well with the DEs deduced from the static current dependence of DE combined with the waveform of a single-photon detection event. This proves that the static measurement results can be used to analyze the transient current recovery process after a detection event. The results are relevant for understanding the current recovery process of SNSPDs after a detection event and for determining the counting rate of SNSPDs.
Superconducting nanowire single photon detectors (SNSPDs) have separately demonstrated high efficiency, low noise, and extremely high speed when detecting single photons. However, achieving all of these simultaneously has been limited by detector subtleties and tradeoffs. Here, we report an SNSPD system with <80 ps timing resolution, kHz noise count rates, and 76% fiber-coupled system detection efficiency in the low-flux limit at 1550 nm. We present a model for determining the detection efficiency penalty due to the detection recovery time, and we validate our method using experimental data obtained at high count rates. We demonstrate improved performance tradeoffs, such as 68% system detection efficiency, including losses due to detector recovery time, when coupled to a Poisson source emitting 100 million photons per second. Our system can provide limited photon number resolution, continuous cryogen-free operation, and scalability to future imaging and GHz-count-rate applications.
A new method to study the transient detection efficiency(DE) and pulse amplitude of superconducting nanowire single photon detectors(SNSPD) during the current recovery process is proposed — statistically analyzing the single photon response under photon illumination with a high repetition rate.The transient DE results match well with the DEs deduced from the static current dependence of DE combined with the waveform of a single-photon detection event.This proves that static measurement results can be used to analyze the transient current recovery process after a detection event.The results are relevant for understanding the current recovery process of SNSPDs after a detection event and for determining the counting rate of SNSPDs.
One of the key properties of single-photon detectors is their recovery time, i.e. the time required for the detector to recover its nominal efficiency. In the case of superconducting nanowire single-photon detectors (SNSPDs), which can feature extremely short recovery times in free-running mode, a precise characterization of this recovery time and its time dynamics is essential for many quantum optics or quantum communication experiments. We introduce a fast and simple method to characterize precisely the recovery time of SNSPDs. It provides full information about the recovery of the efficiency in time for a single or several consecutive detections. We also show how the method can be used to gain insight into the behavior of the bias current inside the nanowire after a detection, which allows predicting the behavior of the detector and its efficiency in any practical experiment using these detectors.
One of the key properties of single-photon detectors is their recovery time, i.e., the time required for the detector to recover its nominal efficiency. In the case of superconducting nanowire single-photon detectors (SNSPDs), which can feature extremely short recovery times in free-running mode, a precise characterization of this recovery time and its time dynamics is essential for many quantum optics or quantum communication experiments. We introduce a fast and simple method to characterize precisely the recovery time of SNSPDs. It provides full information about the recovery of the efficiency in time for a single or several consecutive detections. We also show how the method can be used to gain insight into the behavior of the bias current inside the nanowire after a detection, which allows predicting the behavior of the detector and its efficiency in any practical experiment using these detectors.