Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1208.5776 · Applied Physics Letters

Hot electron bolometer heterodyne receiver with a 4.7-THz quantum cascade laser as a local oscillator

Jenna L. Kloosterman, D. J. Hayton, Yuan Ren, Tsung-Yu Kao, J. Niels Hovenier, J. R. Gao, T. M. Klapwijk, Qing Hu, C. K. Walker, John L. Reno

Published Jan 7, 2013• 94 citations
arXivHTMLPDF

Abstract

We report on a heterodyne receiver designed to observe the astrophysically important neutral atomic oxygen [OI] line at 4.7448 THz. The local oscillator is a third-order distributed feedback quantum cascade laser operating in continuous wave mode at 4.741 THz. A quasi-optical, superconducting NbN hot electron bolometer is used as the mixer. We recorded a double sideband receiver noise temperature (TrecDSB) of 815 K, which is ∼7 times the quantum noise limit (hν2kB) and an Allan variance time of 15 s at an effective noise fluctuation bandwidth of 18 MHz. Heterodyne performance was confirmed by measuring a methanol line spectrum.

DOI
10.1063/1.4774085

Related papers

10.6 μm heterodyne receiver based on a superconducting hot-electron bolometer mixer and a quantum cascade laser

Yuan Ren, DaiXi Zhang, Kangmin Zhou +7 more

We report on the development of a heterodyne receiver at mid-infrared wavelength for high-resolution spectroscopy applications. The receiver employs a superconducting NbN hot electron bolometer as a mixer and a room temperature distributed feedback quantum cascade laser operating at 10.6 μm (28.2 THz) as a local oscillator. The stabilization of the heterodyne receiver has been achieved using a feedback loop controlling the output power of the laser. Improved Allan variance times as well as a double sideband receiver noise temperature of 5000 K and a noise bandwidth of 2.8 GHz of the receiver system are demonstrated.

AIP Advances•Jul 1, 2019•13 citations

An Ultra-High-Sensitivity Superconducting Hot-Electron-Bolometer Heterodyne Receiver at 2.5 THz With an Integrated Low-Power-Consumption Quantum Cascade Laser

Wei Miao, Hao Gao, Zheng Lou +8 more

We report on the demonstration of an ultra-high-sensitivity superconducting hot-electron-bolometer (HEB) heterodyne receiver at 2.5 THz with a low-power-consumption quantum cascade laser (QCL) as its local oscillator (LO). The 2.5-THz QCL, with an electrical power dissipation of about 0.9 W in continuous wave mode, is integrated with a spiral-antenna-coupled niobium nitride HEB mixer in a single block. The mixer performance is barely affected by heat dissipation from the QCL when the receiver is cryogenically cooled either by a wet LHe Dewar or by a closed-cycle 4-K pulse-tube cooler. Measured with a vacuum setup, the heterodyne receiver exhibits a double sideband receiver noise temperature of 800 K at 2.5 THz with the IR filter contribution corrected, which is approximately 7hυ/kB. And the Allan variance time at 80-MHz noise bandwidth is found to be about 10 s when a proportional-integral-derivative controller is adopted to control the LO power.

IEEE Transactions on Terahertz Science and Technology•Sep 6, 2018•9 citations

Noise Temperature and Beam Pattern of a Quasioptical Heterodyne Receiver based on NbN Hot Electron Bolometer Mixer at 5.25 THz

W. Zhang, P. Khosropanah, J. R. Gao +4 more

We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. The terahertz (THz) radiation is quasioptically coupled to the HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuum, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature ( ) of 1150 K, which is 4.5 times h/k (the quantum limit). In addition, the measured far field beam patterns of the integrated lens antenna from 2.5 THz to 5.3 THz show collimated beams that make it reliable to measure using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen (OI) line at 4.7 THz. DSB rec T

Softwaretechnik-Trends•Mar 1, 2010•0 citations

Sensitivity of a hot electron bolometer heterodyne receiver at 4.3 THz

P. Khosropanah, W. M. Laauwen, Merlijn Hajenius +2 more

We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3 THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300 K at the optimum local oscillator (LO) power of 330 nW, which is about 12 times the quantum noise (hν/2kB). Our result indicates that there is no sign of degradation of the mixing process at the super-THz frequencies. Also, a measurement method is introduced where the hot/cold response of the receiver is recorded at constant voltage bias of the mixer, while varying the LO power. We argue that this method provides an accurate measurement of the receiver noise temperature, which is not influenced by the LO power fluctuations and the direct detection effect. Moreover, our sensitivity data suggests that one can achieve a receiver noise temperature of 1420 K at the frequency of [OI] line (4.7 THz), which is scaled from the sensitivity at 4.3 THz with frequency.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 6, 2008•0 citations

Noise temperature and beam pattern of an NbN hot electron bolometer mixer at 5.25 THz

W. Zhang, P. Khosropanah, J. R. Gao +4 more

We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. Terahertz (THz) radiation is quasioptically coupled to a HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuo, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature (TrecDSB) of 1150 K, which is nine times hν/2k, where h is the Planck constant, ν the frequency, and k the Boltzmann constant. In addition, the measured far field beam patterns of the integrated lens antenna show nearly collimated beams from 2.5 to 5.3 THz that allow reliable measurement of TrecDSB using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, making it suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen line at 4.7 THz.

Journal of Applied Physics•Nov 1, 2010•42 citations

3.1-THz Heterodyne Receiver Using an NbTiN Hot-Electron Bolometer Mixer and a Quantum Cascade Laser

Shoichi Shiba, Yoshihisa Irimajiri, T. Yamakura +4 more

We have developed the 3.1-THz heterodyne receiver using an NbTiN Hot-Electron Bolometer (HEB) mixer and a THz Quantum Cascade Laser (THz-QCL) as a local oscillator. A quasi optical twin-slot antenna is adopted for the coupling of the RF signal with the mixer. The receiver noise temperature is measured to be 5600 K in DSB. When the optical loss is corrected, it is as low as 2100 K. This result demonstrates that the NbTiN HEB mixer works with the equivalent level of performance at 3.1 THz in comparison with the NbN HEB mixers usually employed in this frequency region.

IEEE Transactions on Terahertz Science and Technology•Dec 6, 2011•18 citations
We report on a heterodyne receiver designed to observe the astrophysically important neutral atomic oxygen [OI] line at 4.7448 THz. The local oscillator is a third-order distributed feedback quantum cascade laser operating in continuous wave mode at 4.741 THz. A quasi-optical, superconducting NbN hot electron bolometer is used as the mixer. We recorded a double sideband receiver noise temperature (TrecDSB) of 815 K, which is ∼7 times the quantum noise limit (hν2kB) and an Allan variance time of 15 s at an effective noise fluctuation bandwidth of 18 MHz. Heterodyne performance was confirmed by measuring a methanol line spectrum.
We report on the development of a heterodyne receiver at mid-infrared wavelength for high-resolution spectroscopy applications. The receiver employs a superconducting NbN hot electron bolometer as a mixer and a room temperature distributed feedback quantum cascade laser operating at 10.6 μm (28.2 THz) as a local oscillator. The stabilization of the heterodyne receiver has been achieved using a feedback loop controlling the output power of the laser. Improved Allan variance times as well as a double sideband receiver noise temperature of 5000 K and a noise bandwidth of 2.8 GHz of the receiver system are demonstrated.
We report on the demonstration of an ultra-high-sensitivity superconducting hot-electron-bolometer (HEB) heterodyne receiver at 2.5 THz with a low-power-consumption quantum cascade laser (QCL) as its local oscillator (LO). The 2.5-THz QCL, with an electrical power dissipation of about 0.9 W in continuous wave mode, is integrated with a spiral-antenna-coupled niobium nitride HEB mixer in a single block. The mixer performance is barely affected by heat dissipation from the QCL when the receiver is cryogenically cooled either by a wet LHe Dewar or by a closed-cycle 4-K pulse-tube cooler. Measured with a vacuum setup, the heterodyne receiver exhibits a double sideband receiver noise temperature of 800 K at 2.5 THz with the IR filter contribution corrected, which is approximately 7hυ/kB. And the Allan variance time at 80-MHz noise bandwidth is found to be about 10 s when a proportional-integral-derivative controller is adopted to control the LO power.
We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. The terahertz (THz) radiation is quasioptically coupled to the HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuum, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature ( ) of 1150 K, which is 4.5 times h/k (the quantum limit). In addition, the measured far field beam patterns of the integrated lens antenna from 2.5 THz to 5.3 THz show collimated beams that make it reliable to measure using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen (OI) line at 4.7 THz. DSB rec T
We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3 THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300 K at the optimum local oscillator (LO) power of 330 nW, which is about 12 times the quantum noise (hν/2kB). Our result indicates that there is no sign of degradation of the mixing process at the super-THz frequencies. Also, a measurement method is introduced where the hot/cold response of the receiver is recorded at constant voltage bias of the mixer, while varying the LO power. We argue that this method provides an accurate measurement of the receiver noise temperature, which is not influenced by the LO power fluctuations and the direct detection effect. Moreover, our sensitivity data suggests that one can achieve a receiver noise temperature of 1420 K at the frequency of [OI] line (4.7 THz), which is scaled from the sensitivity at 4.3 THz with frequency.
We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. Terahertz (THz) radiation is quasioptically coupled to a HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuo, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature (TrecDSB) of 1150 K, which is nine times hν/2k, where h is the Planck constant, ν the frequency, and k the Boltzmann constant. In addition, the measured far field beam patterns of the integrated lens antenna show nearly collimated beams from 2.5 to 5.3 THz that allow reliable measurement of TrecDSB using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, making it suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen line at 4.7 THz.
We have developed the 3.1-THz heterodyne receiver using an NbTiN Hot-Electron Bolometer (HEB) mixer and a THz Quantum Cascade Laser (THz-QCL) as a local oscillator. A quasi optical twin-slot antenna is adopted for the coupling of the RF signal with the mixer. The receiver noise temperature is measured to be 5600 K in DSB. When the optical loss is corrected, it is as low as 2100 K. This result demonstrates that the NbTiN HEB mixer works with the equivalent level of performance at 3.1 THz in comparison with the NbN HEB mixers usually employed in this frequency region.