AIP Advances
10.6 μm heterodyne receiver based on a superconducting hot-electron bolometer mixer and a quantum cascade laser
Yuan Ren, DaiXi Zhang, Kangmin Zhou, Wei Miao, Wen Zhang, Sheng‐Cai Shi, Vitaly Seleznev, Ivan V. Pentin, Yury B. Vakhtomin, Смирнов Константин Владимирович
Abstract
We report on the development of a heterodyne receiver at mid-infrared wavelength for high-resolution spectroscopy applications. The receiver employs a superconducting NbN hot electron bolometer as a mixer and a room temperature distributed feedback quantum cascade laser operating at 10.6 μm (28.2 THz) as a local oscillator. The stabilization of the heterodyne receiver has been achieved using a feedback loop controlling the output power of the laser. Improved Allan variance times as well as a double sideband receiver noise temperature of 5000 K and a noise bandwidth of 2.8 GHz of the receiver system are demonstrated.