AIP Advances

10.6 μm heterodyne receiver based on a superconducting hot-electron bolometer mixer and a quantum cascade laser

Yuan Ren, DaiXi Zhang, Kangmin Zhou, Wei Miao, Wen Zhang, Sheng‐Cai Shi, Vitaly Seleznev, Ivan V. Pentin, Yury B. Vakhtomin, Смирнов Константин Владимирович

Published Jul 1, 2019• 13 citations
Publisher

Abstract

We report on the development of a heterodyne receiver at mid-infrared wavelength for high-resolution spectroscopy applications. The receiver employs a superconducting NbN hot electron bolometer as a mixer and a room temperature distributed feedback quantum cascade laser operating at 10.6 μm (28.2 THz) as a local oscillator. The stabilization of the heterodyne receiver has been achieved using a feedback loop controlling the output power of the laser. Improved Allan variance times as well as a double sideband receiver noise temperature of 5000 K and a noise bandwidth of 2.8 GHz of the receiver system are demonstrated.

DOI
10.1063/1.5090132

Related papers

Compact heterodyne receiver at 2.8 THz based on a quantum cascade laser and a superconducting bolometer

Zhenyu Yang, Merlijn Hajenius, J. Niels Hovenier +10 more

We report here a sensitivity measurement of an all solid-state heterodyne receiver which uses a twin slot antenna coupled, small superconducting NbN hot electron bolometer as mixer and a semiconductor quantum cascade laser operating at 2.8 THz as local oscillator. We measure a double sideband receiver noise temperature of 3200 K at 2.8 THz and 4.2 K. We find that the optimal LO power is 33 nW measured at HEB and 1.3 /spl mu/W estimated at the QCL, much lower than the output power of the QCL. Such a receiver can be used for high-resolution spectroscopy above 2 THz and is particularly suitable for space-based observatories.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Jan 18, 2006•3 citations

Hot electron bolometer heterodyne receiver with a 4.7-THz quantum cascade laser as a local oscillator

Jenna L. Kloosterman, D. J. Hayton, Yuan Ren +7 more

We report on a heterodyne receiver designed to observe the astrophysically important neutral atomic oxygen [OI] line at 4.7448 THz. The local oscillator is a third-order distributed feedback quantum cascade laser operating in continuous wave mode at 4.741 THz. A quasi-optical, superconducting NbN hot electron bolometer is used as the mixer. We recorded a double sideband receiver noise temperature (TrecDSB) of 815 K, which is ∼7 times the quantum noise limit (hν2kB) and an Allan variance time of 15 s at an effective noise fluctuation bandwidth of 18 MHz. Heterodyne performance was confirmed by measuring a methanol line spectrum.

arXiv:1208.5776•Applied Physics Letters•Jan 7, 2013•94 citations

An Ultra-High-Sensitivity Superconducting Hot-Electron-Bolometer Heterodyne Receiver at 2.5 THz With an Integrated Low-Power-Consumption Quantum Cascade Laser

Wei Miao, Hao Gao, Zheng Lou +8 more

We report on the demonstration of an ultra-high-sensitivity superconducting hot-electron-bolometer (HEB) heterodyne receiver at 2.5 THz with a low-power-consumption quantum cascade laser (QCL) as its local oscillator (LO). The 2.5-THz QCL, with an electrical power dissipation of about 0.9 W in continuous wave mode, is integrated with a spiral-antenna-coupled niobium nitride HEB mixer in a single block. The mixer performance is barely affected by heat dissipation from the QCL when the receiver is cryogenically cooled either by a wet LHe Dewar or by a closed-cycle 4-K pulse-tube cooler. Measured with a vacuum setup, the heterodyne receiver exhibits a double sideband receiver noise temperature of 800 K at 2.5 THz with the IR filter contribution corrected, which is approximately 7hυ/kB. And the Allan variance time at 80-MHz noise bandwidth is found to be about 10 s when a proportional-integral-derivative controller is adopted to control the LO power.

IEEE Transactions on Terahertz Science and Technology•Sep 6, 2018•9 citations

Terahertz-frequency waveguide NbN hot-electron bolometer mixer

Jonathan H. Kawamura, Edward Tong, R. Blundell +5 more

We have developed a low-noise waveguide heterodyne receiver for operation near 1 THz using phonon-cooled NbN hot-electron bolometers. The mixer elements are submicron-sized microbridges of 4 nm-thick NbN film fabricated on a quartz substrate. Operating at a bath temperature of 4.2 K, the double-sideband receiver noise temperature is 760 K at 1.02 THz and 1100 K at 1.26 THz. The local oscillator is provided by solid-state sources, and power measured at the source is less than 1 /spl mu/W. The intermediate frequency bandwidth exceeds 2 GHz. The receiver was used to make the first ground-based heterodyne detection of a celestial spectroscopic line above 1 THz.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•24 citations

Low noise HEB/QCL integrated heterodyne receiver at 2.7 THz

Hao Gao, W. Miao, Z. Lou +6 more

In this paper, we present a low noise integrated heterodyne receiver at 2.7 THz. This heterodyne receiver is based on a superconducting hot electron bolometer (HEB) mixer and a low power consumption quantum cascade laser (QCL) that are both integrated on the same 4 K stage of a pulse tube cooler. We measured the noise temperature of the HEB/QCL integrated heterodyne receiver by using hot and cold blackbody loads in vacuum. The lowest double sideband receiver noise temperature is about 1000 K at 2.7 THz, and reduced to 500 K after eliminating the quasi-optical losses. In addition, the HEB/QCL integrated heterodyne receiver demonstrates an intermediate frequency (IF) noise bandwidth of 4 GHz.

IEEE International Workshop on Electromagnetics: Applications and Student Innovation Competition•May 1, 2016•1 citation

Heterodyne detection at near-infrared wavelengths with a superconducting NbN hot-electron bolometer mixer

Yury Lobanov, Michael Shcherbatenko, Alexander S. Shurakov +12 more

We report on the development of a highly sensitive optical receiver for heterodyne IR spectroscopy at the communication wavelength of 1.5 μm (200 THz) by use of a superconducting hot-electron bolometer. The results are important for the resolution of narrow spectral molecular lines in the near-IR range for the study of astronomical objects, as well as for quantum optical tomography and fiber-optic sensing. Receiver configuration as well as fiber-to-detector light coupling designs are discussed. Light absorption of the superconducting detectors was enhanced by nano-optical antennas, which were coupled to optical fibers. An intermediate frequency (IF) bandwidth of about 3 GHz was found in agreement with measurements at 300 GHz, and a noise figure of about 25 dB was obtained that was only 10 dB above the quantum limit.

Optics Letters•Mar 5, 2014•15 citations
We report on the development of a heterodyne receiver at mid-infrared wavelength for high-resolution spectroscopy applications. The receiver employs a superconducting NbN hot electron bolometer as a mixer and a room temperature distributed feedback quantum cascade laser operating at 10.6 μm (28.2 THz) as a local oscillator. The stabilization of the heterodyne receiver has been achieved using a feedback loop controlling the output power of the laser. Improved Allan variance times as well as a double sideband receiver noise temperature of 5000 K and a noise bandwidth of 2.8 GHz of the receiver system are demonstrated.
We report here a sensitivity measurement of an all solid-state heterodyne receiver which uses a twin slot antenna coupled, small superconducting NbN hot electron bolometer as mixer and a semiconductor quantum cascade laser operating at 2.8 THz as local oscillator. We measure a double sideband receiver noise temperature of 3200 K at 2.8 THz and 4.2 K. We find that the optimal LO power is 33 nW measured at HEB and 1.3 /spl mu/W estimated at the QCL, much lower than the output power of the QCL. Such a receiver can be used for high-resolution spectroscopy above 2 THz and is particularly suitable for space-based observatories.
We report on a heterodyne receiver designed to observe the astrophysically important neutral atomic oxygen [OI] line at 4.7448 THz. The local oscillator is a third-order distributed feedback quantum cascade laser operating in continuous wave mode at 4.741 THz. A quasi-optical, superconducting NbN hot electron bolometer is used as the mixer. We recorded a double sideband receiver noise temperature (TrecDSB) of 815 K, which is ∼7 times the quantum noise limit (hν2kB) and an Allan variance time of 15 s at an effective noise fluctuation bandwidth of 18 MHz. Heterodyne performance was confirmed by measuring a methanol line spectrum.
We report on the demonstration of an ultra-high-sensitivity superconducting hot-electron-bolometer (HEB) heterodyne receiver at 2.5 THz with a low-power-consumption quantum cascade laser (QCL) as its local oscillator (LO). The 2.5-THz QCL, with an electrical power dissipation of about 0.9 W in continuous wave mode, is integrated with a spiral-antenna-coupled niobium nitride HEB mixer in a single block. The mixer performance is barely affected by heat dissipation from the QCL when the receiver is cryogenically cooled either by a wet LHe Dewar or by a closed-cycle 4-K pulse-tube cooler. Measured with a vacuum setup, the heterodyne receiver exhibits a double sideband receiver noise temperature of 800 K at 2.5 THz with the IR filter contribution corrected, which is approximately 7hυ/kB. And the Allan variance time at 80-MHz noise bandwidth is found to be about 10 s when a proportional-integral-derivative controller is adopted to control the LO power.
We have developed a low-noise waveguide heterodyne receiver for operation near 1 THz using phonon-cooled NbN hot-electron bolometers. The mixer elements are submicron-sized microbridges of 4 nm-thick NbN film fabricated on a quartz substrate. Operating at a bath temperature of 4.2 K, the double-sideband receiver noise temperature is 760 K at 1.02 THz and 1100 K at 1.26 THz. The local oscillator is provided by solid-state sources, and power measured at the source is less than 1 /spl mu/W. The intermediate frequency bandwidth exceeds 2 GHz. The receiver was used to make the first ground-based heterodyne detection of a celestial spectroscopic line above 1 THz.
In this paper, we present a low noise integrated heterodyne receiver at 2.7 THz. This heterodyne receiver is based on a superconducting hot electron bolometer (HEB) mixer and a low power consumption quantum cascade laser (QCL) that are both integrated on the same 4 K stage of a pulse tube cooler. We measured the noise temperature of the HEB/QCL integrated heterodyne receiver by using hot and cold blackbody loads in vacuum. The lowest double sideband receiver noise temperature is about 1000 K at 2.7 THz, and reduced to 500 K after eliminating the quasi-optical losses. In addition, the HEB/QCL integrated heterodyne receiver demonstrates an intermediate frequency (IF) noise bandwidth of 4 GHz.
We report on the development of a highly sensitive optical receiver for heterodyne IR spectroscopy at the communication wavelength of 1.5 μm (200 THz) by use of a superconducting hot-electron bolometer. The results are important for the resolution of narrow spectral molecular lines in the near-IR range for the study of astronomical objects, as well as for quantum optical tomography and fiber-optic sensing. Receiver configuration as well as fiber-to-detector light coupling designs are discussed. Light absorption of the superconducting detectors was enhanced by nano-optical antennas, which were coupled to optical fibers. An intermediate frequency (IF) bandwidth of about 3 GHz was found in agreement with measurements at 300 GHz, and a noise figure of about 25 dB was obtained that was only 10 dB above the quantum limit.