Characterization of alkali metal dispensers and non-evaporable getter pumps in ultrahigh vacuum systems for cold atomic sensors

David R. Scherer, David B. Fenner, Joel M. Hensley

Published Oct 9, 2012• 31 citations
arXivHTMLPDF

Abstract

A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and nonevaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the nonevaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. The authors have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.

DOI
10.1116/1.4757950

Related papers

A passively pumped vacuum package sustaining cold atoms for more than 200 days

Bethany J. Little, Gregory W. Hoth, Justin Christensen +5 more

Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.

arXiv:2101.01051•AVS Quantum Science•Jul 15, 2021•39 citations

Centilitre-scale vacuum chamber for compact ultracold quantum technologies

Oliver S. Burrow, Paul F. Osborn, Edward Boughton +5 more

Compact ultra-high vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress towards a truly portable compact vacuum system, however size, weight and power consumption can be prohibitively large, optical access may be limited, and active pumping is often required. Here, we present a centilitre-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fibre. A cold atom demonstrator based on the vacuum cell delivers $10^7$ laser-cooled $^{87}$Rb atoms per second, using minimal electrical power. With continuous Rb gas emission active pumping yields a $10^{-7}\,$mbar equilibrium pressure, and passive pumping stabilises to $3\times 10^{-6}\,$mbar, with a $17\,$day time constant. A passively-pumped vacuum cell, with no Rb dispensing, has currently kept a similar pressure for a year. The passive-pumping vacuum lifetime is several years, estimated from short-term He throughput, with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.

•Jan 19, 2021•1 citation

Stand-alone vacuum cell for compact ultracold quantum technologies

Oliver S. Burrow, Paul F. Osborn, Edward Boughton +5 more

Compact vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress toward a truly portable compact vacuum system; however, size, weight, and power consumption can be prohibitively large, optical access may be limited, and active pumping is often required. Here, we present a centiliter-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fiber. A cold atom demonstrator based on the vacuum cell delivers 107 laser-cooled 87Rb atoms per second, using minimal electrical power. With continuous Rb gas emission, active pumping yields a 10−7 mbar equilibrium pressure, and passive pumping stabilizes to 3×10−6 mbar with a 17 day time constant. A vacuum cell, with no Rb dispensing and only passive pumping, has currently kept a similar pressure for more than 500 days. The passive-pumping vacuum lifetime is several years, which is estimated from short-term He throughput with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.

arXiv:2101.07851•Applied Physics Letters•Sep 20, 2021•45 citations

Novel rubidium atomic beam with an alkali dispenser source

Timothy Roach, Dwayne Henclewood

We describe a novel atomic beam apparatus with a resistively heated alkali dispenser source and a cold-pumped intermediate chamber. Using laser fluorescence spectroscopy we have measured the atomic density to be 3×1011atoms∕m3 and the total flux to be 5×108atoms∕s in a 0.3cm diameter beam. We have also characterized the velocity distribution of the source based on the Doppler-shifted fluorescence spectrum. The compact geometry, flexibility, and simplicity of the beam may make it useful as an optical frequency reference or for experiments on atom-cooling.

Journal of Vacuum Science & Technology A Vacuum Surfaces and Films•Oct 20, 2004•17 citations

Collimated, single-pass atom source from a pulsed alkali metal dispenser for laser-cooling experiments

Kevin L. Moore, Thomas Purdy, Kater W. Murch +3 more

We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.

arXiv:physics/0409011•Review of Scientific Instruments•Jan 7, 2005•22 citations

Enhanced observation time of magneto-optical traps using micro-machined non-evaporable getter pumps

Rodolphe Boudot, J. P. McGilligan, Kaitlin R. Moore +5 more

We show that micro-machined non-evaporable getter pumps (NEGs) can extend the time over which laser cooled atoms can be produced in a magneto-optical trap (MOT), in the absence of other vacuum pumping mechanisms. In a first study, we incorporate a silicon-glass microfabricated ultra-high vacuum (UHV) cell with silicon etched NEG cavities and alumino-silicate glass (ASG) windows and demonstrate the observation of a repeatedly-loading MOT over a 10 min period with a single laser-activated NEG. In a second study, the capacity of passive pumping with laser activated NEG materials is further investigated in a borosilicate glass-blown cuvette cell containing five NEG tablets. In this cell, the MOT remained visible for over 4 days without any external active pumping system. This MOT observation time exceeds the one obtained in the no-NEG scenario by almost five orders of magnitude. The cell scalability and potential vacuum longevity made possible with NEG materials may enable in the future the development of miniaturized cold-atom instruments.

arXiv:2008.00831•Scientific Reports•Oct 6, 2020•34 citations
A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and nonevaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the nonevaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. The authors have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.
Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.
Compact ultra-high vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress towards a truly portable compact vacuum system, however size, weight and power consumption can be prohibitively large, optical access may be limited, and active pumping is often required. Here, we present a centilitre-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fibre. A cold atom demonstrator based on the vacuum cell delivers 10710^7107 laser-cooled 87^{87}87Rb atoms per second, using minimal electrical power. With continuous Rb gas emission active pumping yields a 10−7 10^{-7}\,10−7mbar equilibrium pressure, and passive pumping stabilises to 3×10−6 3\times 10^{-6}\,3×10−6mbar, with a 17 17\,17day time constant. A passively-pumped vacuum cell, with no Rb dispensing, has currently kept a similar pressure for a year. The passive-pumping vacuum lifetime is several years, estimated from short-term He throughput, with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.
Compact vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress toward a truly portable compact vacuum system; however, size, weight, and power consumption can be prohibitively large, optical access may be limited, and active pumping is often required. Here, we present a centiliter-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fiber. A cold atom demonstrator based on the vacuum cell delivers 107 laser-cooled 87Rb atoms per second, using minimal electrical power. With continuous Rb gas emission, active pumping yields a 10−7 mbar equilibrium pressure, and passive pumping stabilizes to 3×10−6 mbar with a 17 day time constant. A vacuum cell, with no Rb dispensing and only passive pumping, has currently kept a similar pressure for more than 500 days. The passive-pumping vacuum lifetime is several years, which is estimated from short-term He throughput with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.
We describe a novel atomic beam apparatus with a resistively heated alkali dispenser source and a cold-pumped intermediate chamber. Using laser fluorescence spectroscopy we have measured the atomic density to be 3×1011atoms∕m3 and the total flux to be 5×108atoms∕s in a 0.3cm diameter beam. We have also characterized the velocity distribution of the source based on the Doppler-shifted fluorescence spectrum. The compact geometry, flexibility, and simplicity of the beam may make it useful as an optical frequency reference or for experiments on atom-cooling.
We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.
We show that micro-machined non-evaporable getter pumps (NEGs) can extend the time over which laser cooled atoms can be produced in a magneto-optical trap (MOT), in the absence of other vacuum pumping mechanisms. In a first study, we incorporate a silicon-glass microfabricated ultra-high vacuum (UHV) cell with silicon etched NEG cavities and alumino-silicate glass (ASG) windows and demonstrate the observation of a repeatedly-loading MOT over a 10 min period with a single laser-activated NEG. In a second study, the capacity of passive pumping with laser activated NEG materials is further investigated in a borosilicate glass-blown cuvette cell containing five NEG tablets. In this cell, the MOT remained visible for over 4 days without any external active pumping system. This MOT observation time exceeds the one obtained in the no-NEG scenario by almost five orders of magnitude. The cell scalability and potential vacuum longevity made possible with NEG materials may enable in the future the development of miniaturized cold-atom instruments.