arXiv:1106.5013 · Applied Physics B

On the application of radio frequency voltages to ion traps via helical resonators

James Siverns, L. R. Simkins, Sebastian Weidt, W. K. Hensinger

Published Jan 16, 2012• 82 citations
arXivHTMLPDF
DOI
10.1007/s00340-011-4837-0

Related papers

Ion transport in macroscopic RF linear traps

J. Pedregosa-Gutierrez, C. Champenois, Marius Romuald Kamsap +1 more

arXiv:1403.2568•International Journal of Mass Spectrometry•Apr 9, 2015•15 citations

A New Measurement Method for High Voltages Applied to an Ion Trap Generated by an RF Resonator

Yunjae Park, Changhyun Jung, Myeongseok Seong +3 more

A new method is proposed to measure unknown amplitudes of radio frequency (RF) voltages applied to ion traps, using a pre-calibrated voltage divider with RF shielding. In contrast to previous approaches that estimate the applied voltage by comparing the measured secular frequencies with a numerical simulation, we propose using a pre-calibrated voltage divider to determine the absolute amplitude of large RF voltages amplified by a helical resonator. The proposed method does not require measurement of secular frequencies and completely removes uncertainty caused by limitations of numerical simulations. To experimentally demonstrate our method, we first obtained a functional relation between measured secular frequencies and large amplitudes of RF voltages using the calibrated voltage divider. A comparison of measured relations and simulation results without any fitting parameters confirmed the validity of the proposed method. Our method can be applied to most ion trap experiments. In particular, it will be an essential tool for surface ion traps which are extremely vulnerable to unknown large RF voltages and for improving the accuracy of numerical simulations for ion trap experiments.

Sensors•Feb 6, 2021•4 citations

Miniature RF Traps for Strong Ion Confinement

Xinxin Zhao, Nan Yu, HANS G. DEHMELT +2 more

APS•May 1, 1996•0 citations

Low power high-performance radio frequency oscillator for driving ion traps

Yuan‐Yu Jau, Francisco Benito, Heather L. Partner +1 more

We report a simple, efficient, high voltage radio frequency (RF) generator powered by a single voltage source (1.5-7 V) to resonantly drive ion traps or other capacitive loads. Our circuit is able to deliver RF voltages > 500 V(p-p) at frequencies ranging from 0.1 to 10 MHz. This RF oscillator uses low-cost, commercially available components, and can be easily assembled onto a circuit board of a few cm(2). Because of its simplicity and good efficiency, this circuit is useful in applications requiring small size and low power consumption such as portable ion trap systems where the duration of operation under battery power is of concern.

Review of Scientific Instruments•Feb 1, 2011•11 citations

Compact radio-frequency resonator for cryogenic ion traps

Davide Gandolfi, M. Niedermayr, M. Kumph +2 more

We report on the investigation and implementation of a lumped-component, radio-frequency resonator used in a cryogenic vacuum environment to drive an ion trap. The resonator was required to achieve the voltages necessary to trap (~100 V), while dissipating very little power. Ultimately, for an input voltage of 1.35 V, a voltage gain of 100 was measured at 5.7 K, using a design which dissipated only 18 mW. The resonator operated at a frequency of 7.64 MHz and had a Q of 700. Single (40)Ca(+) ions were confined in a trap driven by this device, providing proof of successful resonator operation at low temperature.

arXiv:1204.5004•Review of Scientific Instruments•Aug 1, 2012•20 citations

Towards a field-free junction for a network of radio-frequency surface electrode ion traps

R. J ordens, Ulrich Warring, Roman Schmied +4 more

Bulletin of the American Physical Society•Jun 7, 2012•0 citations
A new method is proposed to measure unknown amplitudes of radio frequency (RF) voltages applied to ion traps, using a pre-calibrated voltage divider with RF shielding. In contrast to previous approaches that estimate the applied voltage by comparing the measured secular frequencies with a numerical simulation, we propose using a pre-calibrated voltage divider to determine the absolute amplitude of large RF voltages amplified by a helical resonator. The proposed method does not require measurement of secular frequencies and completely removes uncertainty caused by limitations of numerical simulations. To experimentally demonstrate our method, we first obtained a functional relation between measured secular frequencies and large amplitudes of RF voltages using the calibrated voltage divider. A comparison of measured relations and simulation results without any fitting parameters confirmed the validity of the proposed method. Our method can be applied to most ion trap experiments. In particular, it will be an essential tool for surface ion traps which are extremely vulnerable to unknown large RF voltages and for improving the accuracy of numerical simulations for ion trap experiments.
We report a simple, efficient, high voltage radio frequency (RF) generator powered by a single voltage source (1.5-7 V) to resonantly drive ion traps or other capacitive loads. Our circuit is able to deliver RF voltages > 500 V(p-p) at frequencies ranging from 0.1 to 10 MHz. This RF oscillator uses low-cost, commercially available components, and can be easily assembled onto a circuit board of a few cm(2). Because of its simplicity and good efficiency, this circuit is useful in applications requiring small size and low power consumption such as portable ion trap systems where the duration of operation under battery power is of concern.
We report on the investigation and implementation of a lumped-component, radio-frequency resonator used in a cryogenic vacuum environment to drive an ion trap. The resonator was required to achieve the voltages necessary to trap (~100 V), while dissipating very little power. Ultimately, for an input voltage of 1.35 V, a voltage gain of 100 was measured at 5.7 K, using a design which dissipated only 18 mW. The resonator operated at a frequency of 7.64 MHz and had a Q of 700. Single (40)Ca(+) ions were confined in a trap driven by this device, providing proof of successful resonator operation at low temperature.