Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1103.5253 · New Journal of Physics

High-fidelity state detection and tomography of a single-ion Zeeman qubit

Anna Keselman, Yinnon Glickman, N Akerman, Shlomi Kotler, Roee Ozeri

Published Jul 21, 2011• 40 citations
arXivHTMLPDF

Abstract

We demonstrate high-fidelity Zeeman qubit state detection in a single trapped 88 Sr + ion. Qubit readout is performed by shelving one of the qubit states to a metastable level using a narrow linewidth diode laser at 674 nm, followed by state-selective fluorescence detection. The average fidelity reached for the readout of the qubit state is 0.9989(1). We then measure the fidelity of state tomography, averaged over all possible single-qubit states, which is 0.9979(2). We also fully characterize the detection process using quantum process tomography. This readout fidelity is compatible with recent estimates of the detection error threshold required for fault-tolerant computation, whereas high-fidelity state tomography opens the way for high-precision quantum process tomography.

DOI
10.1088/1367-2630/13/7/073027

Related papers

High fidelity readout of trapped ion qubits

Alice Heather Burrell

This thesis describes experimental demonstrations of high-fidelity readout of trapped ion quantum bits ("qubits") for quantum information processing. We present direct single-shot measurement of an "optical" qubit stored in a single calcium-40 ion by the process of resonance fluorescence with a fidelity of 99.991(1)% (surpassing the level necessary for fault-tolerant quantum computation). A time-resolved maximum likelihood method is used to discriminate efficiently between the two qubit states based on photon-counting information, even in the presence of qubit decay from one state to the other. It also screens out errors due to cosmic ray events in the detector, a phenomenon investigated in this work. An adaptive method allows the 99.99% level to be reached in 145us average detection time. The readout fidelity is asymmetric: 99.9998% is possible for the "bright" qubit state, while retaining 99.98% for the "dark" state. This asymmetry could be exploited in quantum error correction (by encoding the "no-error" syndrome of the ancilla qubits in the "bright" state), as could the likelihood values computed (which quantify confidence in the measurement outcome). We then extend the work to parallel readout of a four-ion string using a CCD camera and achieve the same 99.99% net fidelity, limited by qubit decay in the 400us exposure time. The behaviour of the camera is characterised by fitting experimental data with a model. The additional readout error due to cross-talk between ion images on the CCD is measured in an experiment designed to remove the effect of qubit decay; a spatial maximum likelihood technique is used to reduce this error to only 0.2(1)x10^{-4} per qubit, despite the presence of ~4% optical cross-talk between neighbouring qubits. Studies of the cross-talk indicate that the readout method would scale with negligible loss of fidelity to parallel readout of ~10,000 qubits with a readout time of ~3us per qubit. Monte-Carlo simulations of the readout process are presented for comparison with experimental data; these are also used to explore the parameter space associated with fluorescence detection and to optimise experimental and analysis parameters. Applications of the analysis methods to readout of other atomic and solid-state qubits are discussed.

•Jan 1, 2010•8 citations

High-Fidelity Readout of Trapped-Ion Qubits

A. H. Myerson, D. J. Szwer, S. C. Webster +7 more

We demonstrate single-shot qubit readout with a fidelity sufficient for fault-tolerant quantum computation. For an optical qubit stored in 40Ca+ we achieve 99.991(1)% average readout fidelity in 10(6) trials, using time-resolved photon counting. An adaptive measurement technique allows 99.99% fidelity to be reached in 145 micros average detection time. For 43Ca+, we propose and implement an optical pumping scheme to transfer a long-lived hyperfine qubit to the optical qubit, capable of a theoretical fidelity of 99.95% in 10 micros. We achieve 99.87(4)% transfer fidelity and 99.77(3)% net readout fidelity.

arXiv:0802.1684•Physical Review Letters•May 23, 2008•334 citations

High-Fidelity Ion State Detection Using Trap-Integrated Avalanche Photodiodes

David Reens, Michael Collins, Joseph S. Ciampi +12 more

Integrated technologies greatly enhance the prospects for practical quantum information processing and sensing devices based on trapped ions. High-speed and high-fidelity ion state readout is critical for any such application. Integrated detectors offer significant advantages for system portability and can also greatly facilitate parallel operations if a separate detector can be incorporated at each ion-trapping location. Here, we demonstrate ion quantum state detection at room temperature utilizing single-photon avalanche diodes (SPADs) integrated directly into the substrate of silicon ion trapping chips. We detect the state of a trapped Sr^{+} ion via fluorescence collection with the SPAD, achieving 99.92(1)% average fidelity in 450 μs, opening the door to the application of integrated state detection to quantum computing and sensing utilizing arrays of trapped ions.

arXiv:2202.01715•Physical Review Letters•Sep 2, 2022•34 citations

High-Fidelity Preparation, Gates, Memory, and Readout of a Trapped-Ion Quantum Bit

T. P. Harty, D. T. C. Allcock, Christopher J. Ballance +5 more

We implement all single-qubit operations with fidelities significantly above the minimum threshold required for fault-tolerant quantum computing, using a trapped-ion qubit stored in hyperfine "atomic clock" states of ^{43}Ca^{+}. We measure a combined qubit state preparation and single-shot readout fidelity of 99.93%, a memory coherence time of T_{2}^{*}=50 sec, and an average single-qubit gate fidelity of 99.9999%. These results are achieved in a room-temperature microfabricated surface trap, without the use of magnetic field shielding or dynamic decoupling techniques to overcome technical noise.

arXiv:1403.1524•Physical Review Letters•Nov 24, 2014•632 citations

High-Fidelity Detection of a 171 Yb + Qubit via Leakage-Suppressed Shelving

Xinyu Mai, Liyun Zhang, Longxin Wen +1 more

Abstract High-fidelity quantum state detection is essential for quantum information processing, yet in trapped-ion systems it is fundamentally limited by state leakage arising from off-resonant excitation during fluorescence detection. Here, we demonstrate a leakage-suppressed detection scheme for 171 Yb + qubits based on stateselective shelving to a metastable 2 D 3/2 manifold. This approach effectively suppresses population leakage and significantly enhances detection fidelity. We achieve an average detection fidelity of 99.88(2)%, representing a significant improvement over conventional methods. The scheme requires minimal additional experimental resources and is compatible with existing qubit-control configurations, supporting mid-circuit measurement in trapped-ion systems. With state-of-the-art total photon detection efficiency, a detection fidelity of 99.98% is projected, highlighting its potential for scalable quantum information processing.

Chinese Physics B•May 22, 2026•0 citations

High-fidelity mixed species entanglement of trapped ions

K. Thirumalai

Harnessing quantum mechanics to solve problems intractable on classical computers is one of the foremost goals of applied physics. Trapped ions make an excellent physical platform for such a quantum computer, as they have demonstrated unparalleled qubit operation fidelities and memory times, but significant challenges remain in scaling up these systems. A promising scalable architecture is a photonically connected network of mixed element trapped ion nodes, each containing a few ions of two species. Poor quality remote entanglement links between nodes can be tolerated, if entanglement between ions in the same node can be achieved with high fidelity. While local gates have been repeatedly demonstrated between ions of the same species, the fidelity of mixed element quantum gates have not previously surpassed the fault tolerant threshold, above which errors can in principle be corrected. In this thesis we demonstrate an entangling operation between 43Ca+, useful for its long lived qubits, and 88Sr+, well suited for remote entanglement, using a novel mechanism requiring only one laser to manipulate both species. This relatively simple scheme, which is independent of either qubit frequency, allows us to achieve Bell state fidelities of F = 99.8(1)%. We assess the operation of the gate further with state and process tomography, which achieve Bell state fidelity F = 98.1% and average gate fidelity F̅ = 99.05(6)% respectively, though they are hampered by experimental drifts during the long data collection. Finally, we use interleaved randomised benchmarking to get the best estimate of our gate errors, finding an average gate fidelity of F̅ = 99.62(3)% for a sequence of 60 interleaved gates. Along with a demonstration of entanglement between two 88Sr+ ions, achieved with fidelity F = 95.9(4)%, this work paves the way towards demonstrating an elementary mixed species quantum network in future experiments.

•Jan 1, 2019•3 citations
We demonstrate high-fidelity Zeeman qubit state detection in a single trapped 88 Sr + ion. Qubit readout is performed by shelving one of the qubit states to a metastable level using a narrow linewidth diode laser at 674 nm, followed by state-selective fluorescence detection. The average fidelity reached for the readout of the qubit state is 0.9989(1). We then measure the fidelity of state tomography, averaged over all possible single-qubit states, which is 0.9979(2). We also fully characterize the detection process using quantum process tomography. This readout fidelity is compatible with recent estimates of the detection error threshold required for fault-tolerant computation, whereas high-fidelity state tomography opens the way for high-precision quantum process tomography.
This thesis describes experimental demonstrations of high-fidelity readout of trapped ion quantum bits ("qubits") for quantum information processing. We present direct single-shot measurement of an "optical" qubit stored in a single calcium-40 ion by the process of resonance fluorescence with a fidelity of 99.991(1)% (surpassing the level necessary for fault-tolerant quantum computation). A time-resolved maximum likelihood method is used to discriminate efficiently between the two qubit states based on photon-counting information, even in the presence of qubit decay from one state to the other. It also screens out errors due to cosmic ray events in the detector, a phenomenon investigated in this work. An adaptive method allows the 99.99% level to be reached in 145us average detection time. The readout fidelity is asymmetric: 99.9998% is possible for the "bright" qubit state, while retaining 99.98% for the "dark" state. This asymmetry could be exploited in quantum error correction (by encoding the "no-error" syndrome of the ancilla qubits in the "bright" state), as could the likelihood values computed (which quantify confidence in the measurement outcome). We then extend the work to parallel readout of a four-ion string using a CCD camera and achieve the same 99.99% net fidelity, limited by qubit decay in the 400us exposure time. The behaviour of the camera is characterised by fitting experimental data with a model. The additional readout error due to cross-talk between ion images on the CCD is measured in an experiment designed to remove the effect of qubit decay; a spatial maximum likelihood technique is used to reduce this error to only 0.2(1)x10^{-4} per qubit, despite the presence of ~4% optical cross-talk between neighbouring qubits. Studies of the cross-talk indicate that the readout method would scale with negligible loss of fidelity to parallel readout of ~10,000 qubits with a readout time of ~3us per qubit. Monte-Carlo simulations of the readout process are presented for comparison with experimental data; these are also used to explore the parameter space associated with fluorescence detection and to optimise experimental and analysis parameters. Applications of the analysis methods to readout of other atomic and solid-state qubits are discussed.
We demonstrate single-shot qubit readout with a fidelity sufficient for fault-tolerant quantum computation. For an optical qubit stored in 40Ca+ we achieve 99.991(1)% average readout fidelity in 10(6) trials, using time-resolved photon counting. An adaptive measurement technique allows 99.99% fidelity to be reached in 145 micros average detection time. For 43Ca+, we propose and implement an optical pumping scheme to transfer a long-lived hyperfine qubit to the optical qubit, capable of a theoretical fidelity of 99.95% in 10 micros. We achieve 99.87(4)% transfer fidelity and 99.77(3)% net readout fidelity.
Integrated technologies greatly enhance the prospects for practical quantum information processing and sensing devices based on trapped ions. High-speed and high-fidelity ion state readout is critical for any such application. Integrated detectors offer significant advantages for system portability and can also greatly facilitate parallel operations if a separate detector can be incorporated at each ion-trapping location. Here, we demonstrate ion quantum state detection at room temperature utilizing single-photon avalanche diodes (SPADs) integrated directly into the substrate of silicon ion trapping chips. We detect the state of a trapped Sr^{+} ion via fluorescence collection with the SPAD, achieving 99.92(1)% average fidelity in 450 μs, opening the door to the application of integrated state detection to quantum computing and sensing utilizing arrays of trapped ions.
We implement all single-qubit operations with fidelities significantly above the minimum threshold required for fault-tolerant quantum computing, using a trapped-ion qubit stored in hyperfine "atomic clock" states of ^{43}Ca^{+}. We measure a combined qubit state preparation and single-shot readout fidelity of 99.93%, a memory coherence time of T_{2}^{*}=50 sec, and an average single-qubit gate fidelity of 99.9999%. These results are achieved in a room-temperature microfabricated surface trap, without the use of magnetic field shielding or dynamic decoupling techniques to overcome technical noise.
Abstract High-fidelity quantum state detection is essential for quantum information processing, yet in trapped-ion systems it is fundamentally limited by state leakage arising from off-resonant excitation during fluorescence detection. Here, we demonstrate a leakage-suppressed detection scheme for 171 Yb + qubits based on stateselective shelving to a metastable 2 D 3/2 manifold. This approach effectively suppresses population leakage and significantly enhances detection fidelity. We achieve an average detection fidelity of 99.88(2)%, representing a significant improvement over conventional methods. The scheme requires minimal additional experimental resources and is compatible with existing qubit-control configurations, supporting mid-circuit measurement in trapped-ion systems. With state-of-the-art total photon detection efficiency, a detection fidelity of 99.98% is projected, highlighting its potential for scalable quantum information processing.
Harnessing quantum mechanics to solve problems intractable on classical computers is one of the foremost goals of applied physics. Trapped ions make an excellent physical platform for such a quantum computer, as they have demonstrated unparalleled qubit operation fidelities and memory times, but significant challenges remain in scaling up these systems. A promising scalable architecture is a photonically connected network of mixed element trapped ion nodes, each containing a few ions of two species. Poor quality remote entanglement links between nodes can be tolerated, if entanglement between ions in the same node can be achieved with high fidelity. While local gates have been repeatedly demonstrated between ions of the same species, the fidelity of mixed element quantum gates have not previously surpassed the fault tolerant threshold, above which errors can in principle be corrected. In this thesis we demonstrate an entangling operation between 43Ca+, useful for its long lived qubits, and 88Sr+, well suited for remote entanglement, using a novel mechanism requiring only one laser to manipulate both species. This relatively simple scheme, which is independent of either qubit frequency, allows us to achieve Bell state fidelities of F = 99.8(1)%. We assess the operation of the gate further with state and process tomography, which achieve Bell state fidelity F = 98.1% and average gate fidelity F̅ = 99.05(6)% respectively, though they are hampered by experimental drifts during the long data collection. Finally, we use interleaved randomised benchmarking to get the best estimate of our gate errors, finding an average gate fidelity of F̅ = 99.62(3)% for a sequence of 60 interleaved gates. Along with a demonstration of entanglement between two 88Sr+ ions, achieved with fidelity F = 95.9(4)%, this work paves the way towards demonstrating an elementary mixed species quantum network in future experiments.