Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0802.1684 · Physical Review Letters

High-Fidelity Readout of Trapped-Ion Qubits

A. H. Myerson, D. J. Szwer, S. C. Webster, D. T. C. Allcock, Michael J. Curtis, Gergely Imreh, Jeff A. Sherman, Derek N. Stacey, Andrew M. Steane, D. M. Lucas

Published May 23, 2008• 334 citations
arXivHTMLPDF

Abstract

We demonstrate single-shot qubit readout with a fidelity sufficient for fault-tolerant quantum computation. For an optical qubit stored in 40Ca+ we achieve 99.991(1)% average readout fidelity in 10(6) trials, using time-resolved photon counting. An adaptive measurement technique allows 99.99% fidelity to be reached in 145 micros average detection time. For 43Ca+, we propose and implement an optical pumping scheme to transfer a long-lived hyperfine qubit to the optical qubit, capable of a theoretical fidelity of 99.95% in 10 micros. We achieve 99.87(4)% transfer fidelity and 99.77(3)% net readout fidelity.

DOI
10.1103/physrevlett.100.200502

Related papers

High fidelity readout of trapped ion qubits

Alice Heather Burrell

This thesis describes experimental demonstrations of high-fidelity readout of trapped ion quantum bits ("qubits") for quantum information processing. We present direct single-shot measurement of an "optical" qubit stored in a single calcium-40 ion by the process of resonance fluorescence with a fidelity of 99.991(1)% (surpassing the level necessary for fault-tolerant quantum computation). A time-resolved maximum likelihood method is used to discriminate efficiently between the two qubit states based on photon-counting information, even in the presence of qubit decay from one state to the other. It also screens out errors due to cosmic ray events in the detector, a phenomenon investigated in this work. An adaptive method allows the 99.99% level to be reached in 145us average detection time. The readout fidelity is asymmetric: 99.9998% is possible for the "bright" qubit state, while retaining 99.98% for the "dark" state. This asymmetry could be exploited in quantum error correction (by encoding the "no-error" syndrome of the ancilla qubits in the "bright" state), as could the likelihood values computed (which quantify confidence in the measurement outcome). We then extend the work to parallel readout of a four-ion string using a CCD camera and achieve the same 99.99% net fidelity, limited by qubit decay in the 400us exposure time. The behaviour of the camera is characterised by fitting experimental data with a model. The additional readout error due to cross-talk between ion images on the CCD is measured in an experiment designed to remove the effect of qubit decay; a spatial maximum likelihood technique is used to reduce this error to only 0.2(1)x10^{-4} per qubit, despite the presence of ~4% optical cross-talk between neighbouring qubits. Studies of the cross-talk indicate that the readout method would scale with negligible loss of fidelity to parallel readout of ~10,000 qubits with a readout time of ~3us per qubit. Monte-Carlo simulations of the readout process are presented for comparison with experimental data; these are also used to explore the parameter space associated with fluorescence detection and to optimise experimental and analysis parameters. Applications of the analysis methods to readout of other atomic and solid-state qubits are discussed.

•Jan 1, 2010•8 citations

High-Fidelity Preparation, Gates, Memory, and Readout of a Trapped-Ion Quantum Bit

T. P. Harty, D. T. C. Allcock, Christopher J. Ballance +5 more

We implement all single-qubit operations with fidelities significantly above the minimum threshold required for fault-tolerant quantum computing, using a trapped-ion qubit stored in hyperfine "atomic clock" states of ^{43}Ca^{+}. We measure a combined qubit state preparation and single-shot readout fidelity of 99.93%, a memory coherence time of T_{2}^{*}=50 sec, and an average single-qubit gate fidelity of 99.9999%. These results are achieved in a room-temperature microfabricated surface trap, without the use of magnetic field shielding or dynamic decoupling techniques to overcome technical noise.

arXiv:1403.1524•Physical Review Letters•Nov 24, 2014•632 citations

Trapped Ions Make Impeccable Qubits

Jungsang Kim

We implement all single-qubit operations with fidelities significantly above the minimum threshold required for fault-tolerant quantum computing, using a trapped-ion qubit stored in hyperfine "atomic clock" states of 43 Ca þ .We measure a combined qubit state preparation and single-shot readout fidelity of 99.93%, a memory coherence time of T Ã 2 ¼ 50 sec, and an average single-qubit gate fidelity of 99.9999%.These results are achieved in a room-temperature microfabricated surface trap, without the use of magnetic field shielding or dynamic decoupling techniques to overcome technical noise.

Physics•Nov 24, 2014•5 citations

State Readout of a Trapped Ion Qubit Using a Trap-Integrated Superconducting Photon Detector

Susanna Todaro, Varun Boehm Verma, Katherine C. McCormick +7 more

We report high-fidelity state readout of a trapped ion qubit using a trap-integrated photon detector. We determine the hyperfine qubit state of a single ^{9}Be^{+} ion held in a surface-electrode rf ion trap by counting state-dependent ion fluorescence photons with a superconducting nanowire single-photon detector fabricated into the trap structure. The average readout fidelity is 0.9991(1), with a mean readout duration of 46 μs, and is limited by the polarization impurity of the readout laser beam and by off-resonant optical pumping. Because there are no intervening optical elements between the ion and the detector, we can use the ion fluorescence as a self-calibrated photon source to determine the detector quantum efficiency and its dependence on photon incidence angle and polarization.

arXiv:2008.00065•Physical Review Letters•Jan 6, 2021•98 citations

High-fidelity state detection and tomography of a single-ion Zeeman qubit

Anna Keselman, Yinnon Glickman, N Akerman +2 more

We demonstrate high-fidelity Zeeman qubit state detection in a single trapped 88 Sr + ion. Qubit readout is performed by shelving one of the qubit states to a metastable level using a narrow linewidth diode laser at 674 nm, followed by state-selective fluorescence detection. The average fidelity reached for the readout of the qubit state is 0.9989(1). We then measure the fidelity of state tomography, averaged over all possible single-qubit states, which is 0.9979(2). We also fully characterize the detection process using quantum process tomography. This readout fidelity is compatible with recent estimates of the detection error threshold required for fault-tolerant computation, whereas high-fidelity state tomography opens the way for high-precision quantum process tomography.

arXiv:1103.5253•New Journal of Physics•Jul 21, 2011•40 citations

Scalable simultaneous multiqubit readout with 99.99% single-shot fidelity

Alice Heather Burrell, D. J. Szwer, S. C. Webster +1 more

We describe single-shot readout of a trapped-ion multiqubit register using space- and time-resolved camera detection. For a single qubit we measure $0.9(3)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ readout error in $400$ $\ensuremath{\mu}$s exposure time, limited by the qubit's decay lifetime. For a four-qubit register (a ``qunybble''), we measure an additional error of only $0.1(1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ per qubit, despite the presence of $4%$ optical cross-talk between neighboring qubits. A study of the cross-talk indicates that the method would scale with a negligible loss of fidelity to $~$$10 000$ qubits at a density of $\ensuremath{\lesssim}$$1$ qubit/$\ensuremath{\mu}$m${}^{2}$, with a readout time of $~1$ $\ensuremath{\mu}$s/qubit.

arXiv:0906.3304•Physical Review A•Apr 5, 2010•62 citations
We demonstrate single-shot qubit readout with a fidelity sufficient for fault-tolerant quantum computation. For an optical qubit stored in 40Ca+ we achieve 99.991(1)% average readout fidelity in 10(6) trials, using time-resolved photon counting. An adaptive measurement technique allows 99.99% fidelity to be reached in 145 micros average detection time. For 43Ca+, we propose and implement an optical pumping scheme to transfer a long-lived hyperfine qubit to the optical qubit, capable of a theoretical fidelity of 99.95% in 10 micros. We achieve 99.87(4)% transfer fidelity and 99.77(3)% net readout fidelity.
This thesis describes experimental demonstrations of high-fidelity readout of trapped ion quantum bits ("qubits") for quantum information processing. We present direct single-shot measurement of an "optical" qubit stored in a single calcium-40 ion by the process of resonance fluorescence with a fidelity of 99.991(1)% (surpassing the level necessary for fault-tolerant quantum computation). A time-resolved maximum likelihood method is used to discriminate efficiently between the two qubit states based on photon-counting information, even in the presence of qubit decay from one state to the other. It also screens out errors due to cosmic ray events in the detector, a phenomenon investigated in this work. An adaptive method allows the 99.99% level to be reached in 145us average detection time. The readout fidelity is asymmetric: 99.9998% is possible for the "bright" qubit state, while retaining 99.98% for the "dark" state. This asymmetry could be exploited in quantum error correction (by encoding the "no-error" syndrome of the ancilla qubits in the "bright" state), as could the likelihood values computed (which quantify confidence in the measurement outcome). We then extend the work to parallel readout of a four-ion string using a CCD camera and achieve the same 99.99% net fidelity, limited by qubit decay in the 400us exposure time. The behaviour of the camera is characterised by fitting experimental data with a model. The additional readout error due to cross-talk between ion images on the CCD is measured in an experiment designed to remove the effect of qubit decay; a spatial maximum likelihood technique is used to reduce this error to only 0.2(1)x10^{-4} per qubit, despite the presence of ~4% optical cross-talk between neighbouring qubits. Studies of the cross-talk indicate that the readout method would scale with negligible loss of fidelity to parallel readout of ~10,000 qubits with a readout time of ~3us per qubit. Monte-Carlo simulations of the readout process are presented for comparison with experimental data; these are also used to explore the parameter space associated with fluorescence detection and to optimise experimental and analysis parameters. Applications of the analysis methods to readout of other atomic and solid-state qubits are discussed.
We implement all single-qubit operations with fidelities significantly above the minimum threshold required for fault-tolerant quantum computing, using a trapped-ion qubit stored in hyperfine "atomic clock" states of ^{43}Ca^{+}. We measure a combined qubit state preparation and single-shot readout fidelity of 99.93%, a memory coherence time of T_{2}^{*}=50 sec, and an average single-qubit gate fidelity of 99.9999%. These results are achieved in a room-temperature microfabricated surface trap, without the use of magnetic field shielding or dynamic decoupling techniques to overcome technical noise.
We implement all single-qubit operations with fidelities significantly above the minimum threshold required for fault-tolerant quantum computing, using a trapped-ion qubit stored in hyperfine "atomic clock" states of 43 Ca þ .We measure a combined qubit state preparation and single-shot readout fidelity of 99.93%, a memory coherence time of T Ã 2 ¼ 50 sec, and an average single-qubit gate fidelity of 99.9999%.These results are achieved in a room-temperature microfabricated surface trap, without the use of magnetic field shielding or dynamic decoupling techniques to overcome technical noise.
We report high-fidelity state readout of a trapped ion qubit using a trap-integrated photon detector. We determine the hyperfine qubit state of a single ^{9}Be^{+} ion held in a surface-electrode rf ion trap by counting state-dependent ion fluorescence photons with a superconducting nanowire single-photon detector fabricated into the trap structure. The average readout fidelity is 0.9991(1), with a mean readout duration of 46 μs, and is limited by the polarization impurity of the readout laser beam and by off-resonant optical pumping. Because there are no intervening optical elements between the ion and the detector, we can use the ion fluorescence as a self-calibrated photon source to determine the detector quantum efficiency and its dependence on photon incidence angle and polarization.
We demonstrate high-fidelity Zeeman qubit state detection in a single trapped 88 Sr + ion. Qubit readout is performed by shelving one of the qubit states to a metastable level using a narrow linewidth diode laser at 674 nm, followed by state-selective fluorescence detection. The average fidelity reached for the readout of the qubit state is 0.9989(1). We then measure the fidelity of state tomography, averaged over all possible single-qubit states, which is 0.9979(2). We also fully characterize the detection process using quantum process tomography. This readout fidelity is compatible with recent estimates of the detection error threshold required for fault-tolerant computation, whereas high-fidelity state tomography opens the way for high-precision quantum process tomography.
We describe single-shot readout of a trapped-ion multiqubit register using space- and time-resolved camera detection. For a single qubit we measure $0.9(3)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ readout error in 400400400 $\ensuremath{\mu}$s exposure time, limited by the qubit's decay lifetime. For a four-qubit register (a ``qunybble''), we measure an additional error of only $0.1(1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ per qubit, despite the presence of 44%4 optical cross-talk between neighboring qubits. A study of the cross-talk indicates that the method would scale with a negligible loss of fidelity to  ~ 1000010 00010000 qubits at a density of $\ensuremath{\lesssim}$111 qubit/$\ensuremath{\mu}$m2{}^{2}2, with a readout time of  1~1 1 $\ensuremath{\mu}$s/qubit.