Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1011.4329 · Physical Review Letters

Microwave Photon Counter Based on Josephson Junctions

Yung‐Fu Chen, David J. Hover, S. Sendelbach, Leon N Maurer, Seth Merkel, Emily Pritchett, Frank K. Wilhelm, R. McDermott

Published Nov 14, 2011• 245 citations
arXivHTMLPDF

Abstract

We describe a microwave photon counter based on the current-biased Josephson junction. The junction is tuned to absorb single microwave photons from the incident field, after which it tunnels into a classically observable voltage state. Using two such detectors, we have performed a microwave version of the Hanbury Brown-Twiss experiment at 4 GHz and demonstrated a clear signature of photon bunching for a thermal source. The design is readily scalable to tens of parallelized junctions, a configuration that would allow number-resolved counting of microwave photons.

DOI
10.1103/physrevlett.107.217401

Related papers

Microwave Photon Counter Based on Josephson Junctions

Guilhem J. Ribeill, U. Patel, Joseph Suttle +1 more

The strong interaction of superconducting integrated circuits with microwave photons forms the basis of circuit quantum electrodynamics (cQED), an attractive paradigm for scalable quantum computing and a test bed for quantum optics in the strong coupling regime [1–6]. While singlephoton detectors are an important component of the standard quantum optics toolbox [7], they have not played a role in cQED, as there are no microwave photon counters currently available. In the search for a microwave component that will emulate the nonlinearity of traditional optical photon counters, it is natural to consider the Josephson junction—a nonlinear, nondissipative superconducting circuit element with tunable microwave-frequency transitions. There has been recent interest in the development of on-chip detectors to probe the microwave radiation emitted by mesoscopic quantum circuits [8–14], including proposals to utilize Josephson circuits as photon counters in the context of cQED [8,9]. This study represents the first experimental measurement of the coincidence counting statistics of microwave photons. We exploit microwaveinduced transitions between discrete energy levels in a Josephson junction to realize an efficient, versatile microwave detector. Moreover, we use a parallelized detector circuit to probe the counting statistics of both coherent and thermal microwave sources. Acircuitdiagramofthesingle-channeldetectorisshown in Fig. 1(a). The Josephson junction is current biased near thecriticalcurrent I0.Thejunctionpotentialenergyisgiven by Uð� Þ¼� I

Bulletin of the American Physical Society•Mar 19, 2013•0 citations

Single microwave photon counter based on current-biased Josephson junction

A. Rettaroli, D. Alesini, D. Babusci +17 more

This manuscript is on the design and development of a single microwave photon counter based on a current-biased Josephson junction aimed at the detection of light axion dark matter. Simulations and measurements of a Josephson junction are presented. We observe the junction in a quantum tunneling regime, with subsequent dissipation on an external RC circuit.

IEEE Workshop on Low Temperature Electronics (WOLTE)•Apr 12, 2021•0 citations

Josephson Junctions as Single Microwave Photon Counters: Simulation and Characterization

A. Rettaroli, D. Alesini, D. Babusci +17 more

Detection of light dark matter, such as axion-like particles, puts stringent requirements on the efficiency and dark-count rates of microwave-photon detectors. The possibility of operating a current-biased Josephson junction as a single-microwave photon-detector was investigated through numerical simulations, and through an initial characterization of two Al junctions fabricated by shadow mask evaporation, done in a dilution refrigerator by measuring escape currents at different temperatures, from 40 mK up to the Al transition temperature. The escape dynamics of the junctions were reproduced in the simulation, including the dissipative effects. Inhibition of thermal activation was observed, leaving the macroscopic quantum tunneling as the dominant effect well beyond the crossover temperature.

Instruments•Jul 16, 2021•14 citations

Development of a Josephson junction based single photon microwave detector for axion detection experiments

D Alesini, D Babusci, C. Barone +30 more

Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.

arXiv:2107.01118•Journal of Physics Conference Series•Jun 1, 2020•13 citations

Single Photon Counter Based on a Josephson Junction at 14 GHz for Searching Galactic Axions

L. S. Kuzmin, Alexander S. Sobolev, Claudio D. Gatti +4 more

Axions and axion-like particles appear in well-motivated extensions of the standard model of particle physics and may be the solution to the long-standing puzzle of the dark matter in our Universe. Several new experiments are foreseen in the next decade searching them in a wide range of the parameter space. In the mass region from few to several tens of microelectronvolt, detector sensitivity will be limited by the standard quantum limit of linear amplifiers and a new class of single microwave-photon detector will be needed. We have developed a single photon counter based on the voltage switching of an underdamped Josephson junction that is coupled to a coplanar waveguide. By measuring the switching voltage, we can register single photons at 14 GHz with the rate less than 1 photon per 3000 s.

IEEE Transactions on Applied Superconductivity•Jul 19, 2018•50 citations

Bolometric detection of Josephson radiation

Bayan Karimi, Gorm O. Steffensen, Higginbotham, Andrew P. +3 more

A Josephson junction (JJ) has been under intensive study ever since 1960's. Yet even in the present era of building quantum information processing devices based on many JJs, open questions regarding a single junction remain unsolved, such as quantum phase transitions, coupling of the JJ to an environment and improving coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium (biased) conditions. The bolometer converts ac Josephson current at microwave frequencies, up to about $100\,$GHz, into a measurable dc temperature rise. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements. Using a circuit model, we capture both the current-voltage characteristics and the measured power quantitatively.

arXiv:2402.09314•Feb 14, 2024•0 citations
We describe a microwave photon counter based on the current-biased Josephson junction. The junction is tuned to absorb single microwave photons from the incident field, after which it tunnels into a classically observable voltage state. Using two such detectors, we have performed a microwave version of the Hanbury Brown-Twiss experiment at 4 GHz and demonstrated a clear signature of photon bunching for a thermal source. The design is readily scalable to tens of parallelized junctions, a configuration that would allow number-resolved counting of microwave photons.
The strong interaction of superconducting integrated circuits with microwave photons forms the basis of circuit quantum electrodynamics (cQED), an attractive paradigm for scalable quantum computing and a test bed for quantum optics in the strong coupling regime [1–6]. While singlephoton detectors are an important component of the standard quantum optics toolbox [7], they have not played a role in cQED, as there are no microwave photon counters currently available. In the search for a microwave component that will emulate the nonlinearity of traditional optical photon counters, it is natural to consider the Josephson junction—a nonlinear, nondissipative superconducting circuit element with tunable microwave-frequency transitions. There has been recent interest in the development of on-chip detectors to probe the microwave radiation emitted by mesoscopic quantum circuits [8–14], including proposals to utilize Josephson circuits as photon counters in the context of cQED [8,9]. This study represents the first experimental measurement of the coincidence counting statistics of microwave photons. We exploit microwaveinduced transitions between discrete energy levels in a Josephson junction to realize an efficient, versatile microwave detector. Moreover, we use a parallelized detector circuit to probe the counting statistics of both coherent and thermal microwave sources. Acircuitdiagramofthesingle-channeldetectorisshown in Fig. 1(a). The Josephson junction is current biased near thecriticalcurrent I0.Thejunctionpotentialenergyisgiven by Uð� Þ¼� I
Detection of light dark matter, such as axion-like particles, puts stringent requirements on the efficiency and dark-count rates of microwave-photon detectors. The possibility of operating a current-biased Josephson junction as a single-microwave photon-detector was investigated through numerical simulations, and through an initial characterization of two Al junctions fabricated by shadow mask evaporation, done in a dilution refrigerator by measuring escape currents at different temperatures, from 40 mK up to the Al transition temperature. The escape dynamics of the junctions were reproduced in the simulation, including the dissipative effects. Inhibition of thermal activation was observed, leaving the macroscopic quantum tunneling as the dominant effect well beyond the crossover temperature.
Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.
Axions and axion-like particles appear in well-motivated extensions of the standard model of particle physics and may be the solution to the long-standing puzzle of the dark matter in our Universe. Several new experiments are foreseen in the next decade searching them in a wide range of the parameter space. In the mass region from few to several tens of microelectronvolt, detector sensitivity will be limited by the standard quantum limit of linear amplifiers and a new class of single microwave-photon detector will be needed. We have developed a single photon counter based on the voltage switching of an underdamped Josephson junction that is coupled to a coplanar waveguide. By measuring the switching voltage, we can register single photons at 14 GHz with the rate less than 1 photon per 3000 s.
A Josephson junction (JJ) has been under intensive study ever since 1960's. Yet even in the present era of building quantum information processing devices based on many JJs, open questions regarding a single junction remain unsolved, such as quantum phase transitions, coupling of the JJ to an environment and improving coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium (biased) conditions. The bolometer converts ac Josephson current at microwave frequencies, up to about 100 100\,100GHz, into a measurable dc temperature rise. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements. Using a circuit model, we capture both the current-voltage characteristics and the measured power quantitatively.