Single microwave photon counter based on current-biased Josephson junction

A. Rettaroli, D. Alesini, D. Babusci, Bruno Buonuomo, M. Beretta, Daniele Di Gioacchino, Giulietto Felici, L. Foggetta, A. Gallo, Claudio D. Gatti, Carlo Ligi, Giovanni Maccarrone, S. Tocci, C. Barone, S. Pagano, Gabriella Castellano, F. Chiarello, F. Mattioli, G. Torrioli, Giovanni Filatrella

Published Apr 12, 2021• 0 citations
Publisher

Abstract

This manuscript is on the design and development of a single microwave photon counter based on a current-biased Josephson junction aimed at the detection of light axion dark matter. Simulations and measurements of a Josephson junction are presented. We observe the junction in a quantum tunneling regime, with subsequent dissipation on an external RC circuit.

DOI
10.1109/wolte49037.2021.9555446

Related papers

Josephson Junctions as Single Microwave Photon Counters: Simulation and Characterization

A. Rettaroli, D. Alesini, D. Babusci +17 more

Detection of light dark matter, such as axion-like particles, puts stringent requirements on the efficiency and dark-count rates of microwave-photon detectors. The possibility of operating a current-biased Josephson junction as a single-microwave photon-detector was investigated through numerical simulations, and through an initial characterization of two Al junctions fabricated by shadow mask evaporation, done in a dilution refrigerator by measuring escape currents at different temperatures, from 40 mK up to the Al transition temperature. The escape dynamics of the junctions were reproduced in the simulation, including the dissipative effects. Inhibition of thermal activation was observed, leaving the macroscopic quantum tunneling as the dominant effect well beyond the crossover temperature.

Instruments•Jul 16, 2021•14 citations

Microwave Photon Counter Based on Josephson Junctions

Yung‐Fu Chen, David J. Hover, S. Sendelbach +5 more

We describe a microwave photon counter based on the current-biased Josephson junction. The junction is tuned to absorb single microwave photons from the incident field, after which it tunnels into a classically observable voltage state. Using two such detectors, we have performed a microwave version of the Hanbury Brown-Twiss experiment at 4 GHz and demonstrated a clear signature of photon bunching for a thermal source. The design is readily scalable to tens of parallelized junctions, a configuration that would allow number-resolved counting of microwave photons.

arXiv:1011.4329•Physical Review Letters•Nov 14, 2011•245 citations

Development of a Josephson junction based single photon microwave detector for axion detection experiments

D Alesini, D Babusci, C. Barone +30 more

Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.

arXiv:2107.01118•Journal of Physics Conference Series•Jun 1, 2020•13 citations

Investigation of Resonant Activation in a Josephson Junction for Axion Search With Microwave Single Photon Detection

F. Chiarello, D. Alesini, D. Babusci +18 more

A growing interest in the detection of single microwave-photons has been stimulated by the search for light dark matter, such as Axions and Axion-like particles, together with the fast development of quantum technologies based on superconducting devices. Many solutions have been proposed in literature but most of them still fail to satisfy the tight requirements imposed by Dark Matter experiments. For instance, many have a large dark-count rate that still make parametric amplifiers a preferable choice. On the contrary, a device based on a current biased Josephson junction resonantly activated by the absorption of a microwave photon may have dark-counts rate down to the mHz level. Here, we report the experimental study of the resonant activation of an Al Josephson junction excited by continuous radiofrequency. The device under study consists of a chip with a transmission line terminated by an Al Josephson-junction, fabricated by shadow-mask evaporation technique. The sample-holder with the chip inside is hosted in a superconducting box and it is thermally anchored to the mixing-chamber plate of a dilution refrigerator at a temperature of about 15 mK. We measured the escape rates of the junction in different configurations of current bias and radiofrequency excitations. Response to continuous wave has been measured and interpreted within the RCSJ model. These results are used to optimize the design of a single microwave-photon detector.

IEEE Transactions on Applied Superconductivity•Feb 7, 2022•11 citations

Single Photon Counter Based on a Josephson Junction at 14 GHz for Searching Galactic Axions

L. S. Kuzmin, Alexander S. Sobolev, Claudio D. Gatti +4 more

Axions and axion-like particles appear in well-motivated extensions of the standard model of particle physics and may be the solution to the long-standing puzzle of the dark matter in our Universe. Several new experiments are foreseen in the next decade searching them in a wide range of the parameter space. In the mass region from few to several tens of microelectronvolt, detector sensitivity will be limited by the standard quantum limit of linear amplifiers and a new class of single microwave-photon detector will be needed. We have developed a single photon counter based on the voltage switching of an underdamped Josephson junction that is coupled to a coplanar waveguide. By measuring the switching voltage, we can register single photons at 14 GHz with the rate less than 1 photon per 3000 s.

IEEE Transactions on Applied Superconductivity•Jul 19, 2018•50 citations

Perspectives for Single Microwave Photon Detection

S. Pagano

The detection of single microwave photons is becoming a cornerstone of fundamental experiments in circuit quantum electrodynamics and quantum sensing. Experiments in cavity quantum electrodynamics, photon-mediated entanglement, dark-matter axion searches and quantum thermodynamics increasingly rely on single-photon sensitivity. Current technologies exploit superconducting devices, including Josephson parametric detectors, and transmon-based non-demolition counters for dark-matter haloscopes. Hybrid double quantum dot-Josephson systems reach interesting levels of efficiency, while current-biased Josephson junctions show potential for near-quantumlimited resolution. Despite impressive progress, challenges remain in reducing dark counts, improving reset speed, and scaling for multiplexed arrays. Continued advances in superconducting materials, qubit coherence, and hybrid semiconductor-superconductor designs promise to extend detection efficiency and bandwidth. These developments are poised to enable the next generation of quantum-enabled experiments, from foundational tests in quantum optics to searches for new physics.

Photonics & Electromagnetics Research Symposium - Fall (PIERS-Fall)•Nov 4, 2025•0 citations
This manuscript is on the design and development of a single microwave photon counter based on a current-biased Josephson junction aimed at the detection of light axion dark matter. Simulations and measurements of a Josephson junction are presented. We observe the junction in a quantum tunneling regime, with subsequent dissipation on an external RC circuit.
Detection of light dark matter, such as axion-like particles, puts stringent requirements on the efficiency and dark-count rates of microwave-photon detectors. The possibility of operating a current-biased Josephson junction as a single-microwave photon-detector was investigated through numerical simulations, and through an initial characterization of two Al junctions fabricated by shadow mask evaporation, done in a dilution refrigerator by measuring escape currents at different temperatures, from 40 mK up to the Al transition temperature. The escape dynamics of the junctions were reproduced in the simulation, including the dissipative effects. Inhibition of thermal activation was observed, leaving the macroscopic quantum tunneling as the dominant effect well beyond the crossover temperature.
We describe a microwave photon counter based on the current-biased Josephson junction. The junction is tuned to absorb single microwave photons from the incident field, after which it tunnels into a classically observable voltage state. Using two such detectors, we have performed a microwave version of the Hanbury Brown-Twiss experiment at 4 GHz and demonstrated a clear signature of photon bunching for a thermal source. The design is readily scalable to tens of parallelized junctions, a configuration that would allow number-resolved counting of microwave photons.
Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.
A growing interest in the detection of single microwave-photons has been stimulated by the search for light dark matter, such as Axions and Axion-like particles, together with the fast development of quantum technologies based on superconducting devices. Many solutions have been proposed in literature but most of them still fail to satisfy the tight requirements imposed by Dark Matter experiments. For instance, many have a large dark-count rate that still make parametric amplifiers a preferable choice. On the contrary, a device based on a current biased Josephson junction resonantly activated by the absorption of a microwave photon may have dark-counts rate down to the mHz level. Here, we report the experimental study of the resonant activation of an Al Josephson junction excited by continuous radiofrequency. The device under study consists of a chip with a transmission line terminated by an Al Josephson-junction, fabricated by shadow-mask evaporation technique. The sample-holder with the chip inside is hosted in a superconducting box and it is thermally anchored to the mixing-chamber plate of a dilution refrigerator at a temperature of about 15 mK. We measured the escape rates of the junction in different configurations of current bias and radiofrequency excitations. Response to continuous wave has been measured and interpreted within the RCSJ model. These results are used to optimize the design of a single microwave-photon detector.
Axions and axion-like particles appear in well-motivated extensions of the standard model of particle physics and may be the solution to the long-standing puzzle of the dark matter in our Universe. Several new experiments are foreseen in the next decade searching them in a wide range of the parameter space. In the mass region from few to several tens of microelectronvolt, detector sensitivity will be limited by the standard quantum limit of linear amplifiers and a new class of single microwave-photon detector will be needed. We have developed a single photon counter based on the voltage switching of an underdamped Josephson junction that is coupled to a coplanar waveguide. By measuring the switching voltage, we can register single photons at 14 GHz with the rate less than 1 photon per 3000 s.
The detection of single microwave photons is becoming a cornerstone of fundamental experiments in circuit quantum electrodynamics and quantum sensing. Experiments in cavity quantum electrodynamics, photon-mediated entanglement, dark-matter axion searches and quantum thermodynamics increasingly rely on single-photon sensitivity. Current technologies exploit superconducting devices, including Josephson parametric detectors, and transmon-based non-demolition counters for dark-matter haloscopes. Hybrid double quantum dot-Josephson systems reach interesting levels of efficiency, while current-biased Josephson junctions show potential for near-quantumlimited resolution. Despite impressive progress, challenges remain in reducing dark counts, improving reset speed, and scaling for multiplexed arrays. Continued advances in superconducting materials, qubit coherence, and hybrid semiconductor-superconductor designs promise to extend detection efficiency and bandwidth. These developments are poised to enable the next generation of quantum-enabled experiments, from foundational tests in quantum optics to searches for new physics.