Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2402.09314

Bolometric detection of Josephson radiation

Bayan Karimi, Gorm O. Steffensen, Higginbotham, Andrew P., Charles M. Marcus, A. Levy Yeyati, Jukka P Pekola

Published Feb 14, 2024• 0 citations
arXivHTMLPDF

Abstract

A Josephson junction (JJ) has been under intensive study ever since 1960's. Yet even in the present era of building quantum information processing devices based on many JJs, open questions regarding a single junction remain unsolved, such as quantum phase transitions, coupling of the JJ to an environment and improving coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium (biased) conditions. The bolometer converts ac Josephson current at microwave frequencies, up to about $100\,$GHz, into a measurable dc temperature rise. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements. Using a circuit model, we capture both the current-voltage characteristics and the measured power quantitatively.

DOI
10.48550/arxiv.2402.09314

Related papers

Bolometric detection of Josephson radiation

Bayan Karimi, Gorm O. Steffensen, Andrew P. Higginbotham +3 more

One of the most promising approaches towards large-scale quantum computation uses devices based on many Josephson junctions. Yet, even today, open questions regarding the single junction remain unsolved, such as the detailed understanding of the quantum phase transitions, the coupling of the Josephson junction to the environment or how to improve the coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir connected to a Josephson junction that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium, that is, biased conditions. The bolometer converts the a.c. Josephson current at microwave frequencies up to about 100 GHz into a temperature rise measured by d.c. thermometry. A circuit model based on realistic parameter values captures both the current-voltage characteristics and the measured power quantitatively. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements.

Nature Nanotechnology•Aug 22, 2024•9 citations

DC-operated Josephson junction arrays as a cryogenic on-chip microwave measurement platform

Senne Vervoort, Lukas Nulens, Davi A. D. Chaves +8 more

Abstract Providing radio frequency (RF) signals to cryogenic circuits requires bulky and expensive cabling interfacing specialized RF electronics at room temperature. Superconducting-normal metal-superconducting Josephson junction arrays (JJAs) can change this paradigm by placing the RF source and detector on-chip. In this work, we demonstrate that DC-biased JJAs can emit signals in the C-band frequency spectrum and beyond, with a minimal linewidth of 106.5 ± 0.1 MHz and maximum power of 11.9 fW. We fabricate JJAs comprised of amorphous MoGe or NbTiN superconducting islands and metallic Au weak links. Temperature, magnetic field, applied current, and device design are explored to control the RF sources, while we identify important features that affect the ideal source behavior. Combined with the ability of these JJAs to detect microwave radiation, these sources allow us to propose a fully DC-operated cryogenic on-chip measurement platform that is an alternative to the high-frequency circuitry currently required for quantum applications.

arXiv:2412.17576•Communications Physics•Jul 12, 2025•2 citations

Quantum Microwave Photodetection Using Superconducting Josephson Circuits.

Brendan Osberg

Superconducting circuits have recently become a major contender for the implementation of quantum computers owing to their compatibility with existing microchip fabrication technologies. Their utility stems largely from their ability to be coupled with resonant cavities for the purposes of trapping and relaying microwave radiation. Because of this feature, scientists are able to transmit quantum information from a variety of qubits. Though quantum-limited amplifiers exist, unfortunately there currently exists no microwave photon counter capable of single shot quantum detection. Hence, we use superconducting circuits with Josephson junctions to design a microwave photon detector based on a modified phase qubit that exhibits a bandwidth of 4GHz, and a detection fidelity of 98%. We use metastable barrier transition (driven by incident photons) to create an avalanche effect analogous to current photo-diodes. Linear coupling of the junction flux with the radiation permits photodetection from an arbitrary quantum source in the GHz range. We show the device to be robust to changes in drive frequency, temporal photon width, and resonator quality factor, and we optimize our device with respect to these parameters. We show the device to be stable over the necessary time scales, and yet sensitive enough to accurately measure photons on demand.

•Sep 3, 2009•0 citations

Resonant switching current detector based on underdamped Josephson junctions

V. M. Krasnov

Current-biased Josephson junctions can act as detectors of electromagnetic radiation. At optimal conditions, their sensitivity is limited by fluctuations causing stochastic switching from the superconducting to the resistive state. This work provides a quantitative description of a stochastic switching current detector, based on an underdamped Josephson junction. It is shown that activation of a Josephson plasma resonance can greatly enhance the detector responsivity in proportion to the quality factor of the junction. The ways of tuning the detector for achieving optimal operation are discussed. For realistic parameters of Nb / Al O x / Nb tunnel junctions, the sensitivity and noise-equivalent power (NEP) can reach values of S ≃ 5 × 10 12 (V/W) and NEP ≃ 2 × 10 − 23 ( WHz − 1 / 2 ), respectively. These outstanding characteristics facilitate both bolometric and single-photon detection in microwave and terahertz ranges. Published by the American Physical Society 2024

arXiv:2403.03803•Physical Review Applied•Aug 6, 2024•9 citations

Thermal sensing for quantum thermodynamics experiments on superconducting circuits

Christoforus Dimas Satrya

Superconducting circuits provide a controllable and versatile platform for studying quantum phenomena and advancing quantum technologies. Josephson junctions and resonators are the central circuit elements, as they enable the realization of macroscopic quantum systems—such as qubits—that can be conveniently controlled, probed, and integrated with non-superconducting components. The implementation of a thermal reservoir through the integration of a dissipative element, such as a normal-metal resistor, offers an experimental platform for investigating quantum thermodynamics, heat management in circuits, on-chip thermal detectors, and the realization of quantum thermal machines. In this thesis, we integrate a mesoscopic normal metal and its associated thermometers as an on-chip bolometer within circuit quantum electrodynamics devices for thermal detection and quantum thermodynamics experiments. The on-chip bolometer is utilized as a sensitive and broadband thermal spectrometer to characterize the properties of a superconducting resonator and to investigate its dominant loss channels. We demonstrate the capability of our thermal detector to resolve the resonator modes over a wide frequency range extending above 20 GHz. When two thermal baths are connected through a qubit–resonator system, a quantum heat valve can be realized. This device has been demonstrated using both transmon and flux qubits. Photonic heat transport between the two baths is controlled by tuning the qubit energy via an applied static magnetic field. To model these experiments, we propose an approach based on electromagnetic simulation and microwave circuit theory, restricted to the linear-response regime. Despite this limitation, the method successfully captures the experimental observations and provides a practical tool for analysing and designing circuits for future experiments. A periodically driven qubit coupled to two unequal resonators, each terminated by a heat reservoir, enables the realization of a quantum Otto refrigerator. The use of a transmon qubit for this purpose is limited by its weak anharmonicity. We therefore explore alternative platforms for the experimental implementation of a quantum refrigerator based on charge and flux qubits, which exhibit strong anharmonicity. As an important step, we perform experiments on a driven flux qubit galvanically coupled to a resonator that is, in turn, weakly capacitively coupled to a heat reservoir. We observe interference patterns in the heat current arising from driving-induced coherence. In particular, resonance peaks in the heat transferred to the bath appear at driving frequencies that are integer fractions of the resonator frequency. These quantum features are governed by the relative phase accumulated by the qubit states under driving.

•Jan 1, 2026•0 citations

Terahertz transmission spectroscopy by Josephson oscillator and cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin, Evgueni Stepantsov +4 more

For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 8, 2004•3 citations
A Josephson junction (JJ) has been under intensive study ever since 1960's. Yet even in the present era of building quantum information processing devices based on many JJs, open questions regarding a single junction remain unsolved, such as quantum phase transitions, coupling of the JJ to an environment and improving coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium (biased) conditions. The bolometer converts ac Josephson current at microwave frequencies, up to about 100 100\,100GHz, into a measurable dc temperature rise. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements. Using a circuit model, we capture both the current-voltage characteristics and the measured power quantitatively.
One of the most promising approaches towards large-scale quantum computation uses devices based on many Josephson junctions. Yet, even today, open questions regarding the single junction remain unsolved, such as the detailed understanding of the quantum phase transitions, the coupling of the Josephson junction to the environment or how to improve the coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir connected to a Josephson junction that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium, that is, biased conditions. The bolometer converts the a.c. Josephson current at microwave frequencies up to about 100 GHz into a temperature rise measured by d.c. thermometry. A circuit model based on realistic parameter values captures both the current-voltage characteristics and the measured power quantitatively. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements.
Abstract Providing radio frequency (RF) signals to cryogenic circuits requires bulky and expensive cabling interfacing specialized RF electronics at room temperature. Superconducting-normal metal-superconducting Josephson junction arrays (JJAs) can change this paradigm by placing the RF source and detector on-chip. In this work, we demonstrate that DC-biased JJAs can emit signals in the C-band frequency spectrum and beyond, with a minimal linewidth of 106.5 ± 0.1 MHz and maximum power of 11.9 fW. We fabricate JJAs comprised of amorphous MoGe or NbTiN superconducting islands and metallic Au weak links. Temperature, magnetic field, applied current, and device design are explored to control the RF sources, while we identify important features that affect the ideal source behavior. Combined with the ability of these JJAs to detect microwave radiation, these sources allow us to propose a fully DC-operated cryogenic on-chip measurement platform that is an alternative to the high-frequency circuitry currently required for quantum applications.
Superconducting circuits have recently become a major contender for the implementation of quantum computers owing to their compatibility with existing microchip fabrication technologies. Their utility stems largely from their ability to be coupled with resonant cavities for the purposes of trapping and relaying microwave radiation. Because of this feature, scientists are able to transmit quantum information from a variety of qubits. Though quantum-limited amplifiers exist, unfortunately there currently exists no microwave photon counter capable of single shot quantum detection. Hence, we use superconducting circuits with Josephson junctions to design a microwave photon detector based on a modified phase qubit that exhibits a bandwidth of 4GHz, and a detection fidelity of 98%. We use metastable barrier transition (driven by incident photons) to create an avalanche effect analogous to current photo-diodes. Linear coupling of the junction flux with the radiation permits photodetection from an arbitrary quantum source in the GHz range. We show the device to be robust to changes in drive frequency, temporal photon width, and resonator quality factor, and we optimize our device with respect to these parameters. We show the device to be stable over the necessary time scales, and yet sensitive enough to accurately measure photons on demand.
Current-biased Josephson junctions can act as detectors of electromagnetic radiation. At optimal conditions, their sensitivity is limited by fluctuations causing stochastic switching from the superconducting to the resistive state. This work provides a quantitative description of a stochastic switching current detector, based on an underdamped Josephson junction. It is shown that activation of a Josephson plasma resonance can greatly enhance the detector responsivity in proportion to the quality factor of the junction. The ways of tuning the detector for achieving optimal operation are discussed. For realistic parameters of Nb / Al O x / Nb tunnel junctions, the sensitivity and noise-equivalent power (NEP) can reach values of S ≃ 5 × 10 12 (V/W) and NEP ≃ 2 × 10 − 23 ( WHz − 1 / 2 ), respectively. These outstanding characteristics facilitate both bolometric and single-photon detection in microwave and terahertz ranges. Published by the American Physical Society 2024
Superconducting circuits provide a controllable and versatile platform for studying quantum phenomena and advancing quantum technologies. Josephson junctions and resonators are the central circuit elements, as they enable the realization of macroscopic quantum systems—such as qubits—that can be conveniently controlled, probed, and integrated with non-superconducting components. The implementation of a thermal reservoir through the integration of a dissipative element, such as a normal-metal resistor, offers an experimental platform for investigating quantum thermodynamics, heat management in circuits, on-chip thermal detectors, and the realization of quantum thermal machines. In this thesis, we integrate a mesoscopic normal metal and its associated thermometers as an on-chip bolometer within circuit quantum electrodynamics devices for thermal detection and quantum thermodynamics experiments. The on-chip bolometer is utilized as a sensitive and broadband thermal spectrometer to characterize the properties of a superconducting resonator and to investigate its dominant loss channels. We demonstrate the capability of our thermal detector to resolve the resonator modes over a wide frequency range extending above 20 GHz. When two thermal baths are connected through a qubit–resonator system, a quantum heat valve can be realized. This device has been demonstrated using both transmon and flux qubits. Photonic heat transport between the two baths is controlled by tuning the qubit energy via an applied static magnetic field. To model these experiments, we propose an approach based on electromagnetic simulation and microwave circuit theory, restricted to the linear-response regime. Despite this limitation, the method successfully captures the experimental observations and provides a practical tool for analysing and designing circuits for future experiments. A periodically driven qubit coupled to two unequal resonators, each terminated by a heat reservoir, enables the realization of a quantum Otto refrigerator. The use of a transmon qubit for this purpose is limited by its weak anharmonicity. We therefore explore alternative platforms for the experimental implementation of a quantum refrigerator based on charge and flux qubits, which exhibit strong anharmonicity. As an important step, we perform experiments on a driven flux qubit galvanically coupled to a resonator that is, in turn, weakly capacitively coupled to a heat reservoir. We observe interference patterns in the heat current arising from driving-induced coherence. In particular, resonance peaks in the heat transferred to the bath appear at driving frequencies that are integer fractions of the resonator frequency. These quantum features are governed by the relative phase accumulated by the qubit states under driving.
For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.