arXiv:1008.1603 · Physical Review A

Surface-electrode point Paul trap

Tony Hyun Kim, Peter F. Herskind, Taehyun Kim, Jungsang Kim, Isaac L. Chuang

Published Oct 12, 2010• 38 citations
arXivHTMLPDF

Abstract

We present a model as well as experimental results for a surface electrode radiofrequency Paul trap that has a circular electrode geometry well suited for trapping single ions and two-dimensional planar ion crystals. The trap design is compatible with microfabrication and offers a simple method by which the height of the trapped ions above the surface may be changed in situ. We demonstrate trapping of single $^{88}\mathrm{Sr}$${}^{+}$ ions over an ion height range of $200\ensuremath{-}1000$ $\ensuremath{\mu}$m for several hours under Doppler laser cooling and use these to characterize the trap, finding good agreement with our model.

DOI
10.1103/physreva.82.043412

Related papers

Surface-electrode point Paul trap

Isaac L. Chuang, Tony Hyun Kim, Peter F. Herskind +2 more

We present a model as well as experimental results for a surface electrode radiofrequency Paul trap that has a circular electrode geometry well suited for trapping single ions and two-dimensional planar ion crystals. The trap design is compatible with microfabrication and offers a simple method by which the height of the trapped ions above the surface may be changed in situ. We demonstrate trapping of single [superscript 88]Sr[superscript +] ions over an ion height range of 200-1000 mu m for several hours under Doppler laser cooling and use these to characterize the trap, finding good agreement with our model.

APS•Oct 1, 2010•0 citations

Surface trap with dc-tunable ion-electrode distance

Da An, Clemens Matthiesen, Ahmed Abdelrahman +5 more

We describe the design, fabrication, and operation of a novel surface-electrode Paul trap that produces a radio-frequency-null along the axis perpendicular to the trap surface. This arrangement enables control of the vertical trapping potential and consequentially the ion-electrode distance via dc-electrodes only. We demonstrate the confinement of single 40Ca+ ions at heights between 50 μm and 300 μm above planar copper-coated aluminum electrodes. Laser-cooling and coherent operations are performed on both the planar and vertical motional modes. This architecture provides a platform for precision electric-field noise detection and trapping of vertical ion strings without excess micromotion and may have applications for scalable quantum computers with surface ion traps.

arXiv:1807.06043•Review of Scientific Instruments•Sep 1, 2018•13 citations

Microfabricated Surface-Electrode Ion Trap for Scalable Quantum Information Processing

Signe Louise Seidelin, John Chiaverini, R. Reichle +13 more

Individual laser-cooled 24Mg+ ions are confined in a linear Paul trap with a novel geometry where gold electrodes are located in a single plane and the ions are trapped 40 microm above this plane. The relatively simple trap design and fabrication procedure are important for large-scale quantum information processing (QIP) using ions. Measured ion motional frequencies are compared to simulations. Measurements of ion recooling after cooling is temporarily suspended yield a heating rate of approximately 5 motional quanta per millisecond for a trap frequency of 2.83 MHz, sufficiently low to be useful for QIP.

arXiv:quant-ph/0601173•Physical Review Letters•Jun 30, 2006•453 citations

Implementation of a symmetric surface-electrode ion trap with field compensation using a modulated Raman effect

D. T. C. Allcock, J A Sherman, Derek N. Stacey +8 more

We describe a new electrode design for a surface-electrode Paul trap, which allows rotation of the normal modes out of the trap plane, and a technique for micromotion compensation in all directions using a two-photon process, which avoids the need for an ultraviolet laser directed to the trap plane. The fabrication and characterization of the trap are described, as well as its implementation for the trapping and cooling of single Ca + ions. We also propose a repumping scheme that increases ion fluorescence and simplifies heating rate measurements obtained by time-resolved ion fluorescence during Doppler cooling.

arXiv:0909.3272•New Journal of Physics•May 17, 2010•73 citations

Microfabricated Paul traps for levitating and shuttling of ions and charged particles

Hwanjit Rattanasonti

Trapped ions in Paul traps (radio frequency ion traps) are a promising candidate for the realization of a quantum computer. To date, experimental demonstrations of quantum computing and information processing with trapped ions have been limited to small numbers of quantum bits (qubits). The most prominent challenge to realise ion-trap quantum computation is to scale the system and control a large number of trapped ions coherently. Surface-electrode ion trap designs which are amenable to various microfabrication techniques offer a path to achieve this. In this work, design, fabrication and key operations of two types of surface-electrode ion traps, i.e. a Y-junction trap and a two-dimensional (2D) hexagonal lattice trap developed towards scaling ion-trap architectures, are presented. The steps involved in the fabrication of the ion-trap devices included photolithography, wet etch (hydrofluoric acid etch) and dry etch (deep reactive ion and inductively coupled plasma etching), and metal evaporation. The devices were fabricated on SOI substrates with different buried oxide thicknesses (i.e. 5 µm and 10 µm) and different metals for the trap electrodes (i.e. gold and aluminium). An extremely high-breakdown voltage up to 1 kV was measured in vacuum for the SOI-built test devices with a 10 µm-thick buried oxide formed by oxide film-to-oxide film bonding process. This is attributed to the deep V-shaped undercut profile of the buried oxide layer which resulted in a large breakdown path length, and so mitigating surface breakdown effects. Owing to the V-shaped undercut profile, the surface breakdown voltage was improved by 15% for the devices fabricated on SOI substrates with a 10 µm-thick buried oxide. In the first experiment, the demonstration of ytterbium (174Yb+) ion trapping in the 2D hexagonal lattice trap is achieved with a relatively long lifetime of a laser-cooled ion up to 90 minutes and ≤ 5 minutes without cooling in ultra-high vacuum system. The 2D lattice trap design allows for reliable trapping of 2D ion lattices, rudimentary shuttling between lattice sites and deterministic introducing of defects into the ion lattice. Based on all these abilities, such a 2D lattice trap with the predicted reduction of lattice spacing down to 32 µm can be configured as a versatile architecture for 2D quantum simulations with trapped ions. In the second experiment, microparticle trapping in the 2D lattice trap, performed in air, is achieved with the longest trapping lifetime of 60 minutes. Both gold and aluminium-coated electrodes also lead to comparable trapping performances. Furthermore, the in situ levitation of microparticles is successfully demonstrated at the maximum levitation height of 30 µm. This ability provides additional control on the trapping height which increases the overall functionality of the 2D lattice trap.

•Jan 1, 2015•0 citations

Micro-fabricated stylus ion trap

Christian Lew Arrington, Kyle S. McKay, Ehren Donel Baca +14 more

An electroformed, three-dimensional stylus Paul trap was designed to confine a single atomic ion for use as a sensor to probe the electric-field noise of proximate surfaces. The trap was microfabricated with the UV-LIGA technique to reduce the distance of the ion from the surface of interest. We detail the fabrication process used to produce a 150 μm tall stylus trap with feature sizes of 40 μm. We confined single, laser-cooled, (25)Mg(+) ions with lifetimes greater than 2 h above the stylus trap in an ultra-high-vacuum environment. After cooling a motional mode of the ion at 4 MHz close to its ground state (<n> = 0.34 ± 0.07), the heating rate of the trap was measured with Raman sideband spectroscopy to be 387 ± 15 quanta/s at an ion height of 62 μm above the stylus electrodes.

Review of Scientific Instruments•Aug 1, 2013•25 citations
We present a model as well as experimental results for a surface electrode radiofrequency Paul trap that has a circular electrode geometry well suited for trapping single ions and two-dimensional planar ion crystals. The trap design is compatible with microfabrication and offers a simple method by which the height of the trapped ions above the surface may be changed in situ. We demonstrate trapping of single ^{88}\mathrm{Sr}$${}^{+} ions over an ion height range of 200\ensuremath−1000200\ensuremath{-}1000200\ensuremath−1000 \ensuremathμ\ensuremath{\mu}\ensuremathμm for several hours under Doppler laser cooling and use these to characterize the trap, finding good agreement with our model.
We present a model as well as experimental results for a surface electrode radiofrequency Paul trap that has a circular electrode geometry well suited for trapping single ions and two-dimensional planar ion crystals. The trap design is compatible with microfabrication and offers a simple method by which the height of the trapped ions above the surface may be changed in situ. We demonstrate trapping of single [superscript 88]Sr[superscript +] ions over an ion height range of 200-1000 mu m for several hours under Doppler laser cooling and use these to characterize the trap, finding good agreement with our model.
We describe the design, fabrication, and operation of a novel surface-electrode Paul trap that produces a radio-frequency-null along the axis perpendicular to the trap surface. This arrangement enables control of the vertical trapping potential and consequentially the ion-electrode distance via dc-electrodes only. We demonstrate the confinement of single 40Ca+ ions at heights between 50 μm and 300 μm above planar copper-coated aluminum electrodes. Laser-cooling and coherent operations are performed on both the planar and vertical motional modes. This architecture provides a platform for precision electric-field noise detection and trapping of vertical ion strings without excess micromotion and may have applications for scalable quantum computers with surface ion traps.
Individual laser-cooled 24Mg+ ions are confined in a linear Paul trap with a novel geometry where gold electrodes are located in a single plane and the ions are trapped 40 microm above this plane. The relatively simple trap design and fabrication procedure are important for large-scale quantum information processing (QIP) using ions. Measured ion motional frequencies are compared to simulations. Measurements of ion recooling after cooling is temporarily suspended yield a heating rate of approximately 5 motional quanta per millisecond for a trap frequency of 2.83 MHz, sufficiently low to be useful for QIP.
We describe a new electrode design for a surface-electrode Paul trap, which allows rotation of the normal modes out of the trap plane, and a technique for micromotion compensation in all directions using a two-photon process, which avoids the need for an ultraviolet laser directed to the trap plane. The fabrication and characterization of the trap are described, as well as its implementation for the trapping and cooling of single Ca + ions. We also propose a repumping scheme that increases ion fluorescence and simplifies heating rate measurements obtained by time-resolved ion fluorescence during Doppler cooling.
Trapped ions in Paul traps (radio frequency ion traps) are a promising candidate for the realization of a quantum computer. To date, experimental demonstrations of quantum computing and information processing with trapped ions have been limited to small numbers of quantum bits (qubits). The most prominent challenge to realise ion-trap quantum computation is to scale the system and control a large number of trapped ions coherently. Surface-electrode ion trap designs which are amenable to various microfabrication techniques offer a path to achieve this. In this work, design, fabrication and key operations of two types of surface-electrode ion traps, i.e. a Y-junction trap and a two-dimensional (2D) hexagonal lattice trap developed towards scaling ion-trap architectures, are presented. The steps involved in the fabrication of the ion-trap devices included photolithography, wet etch (hydrofluoric acid etch) and dry etch (deep reactive ion and inductively coupled plasma etching), and metal evaporation. The devices were fabricated on SOI substrates with different buried oxide thicknesses (i.e. 5 µm and 10 µm) and different metals for the trap electrodes (i.e. gold and aluminium). An extremely high-breakdown voltage up to 1 kV was measured in vacuum for the SOI-built test devices with a 10 µm-thick buried oxide formed by oxide film-to-oxide film bonding process. This is attributed to the deep V-shaped undercut profile of the buried oxide layer which resulted in a large breakdown path length, and so mitigating surface breakdown effects. Owing to the V-shaped undercut profile, the surface breakdown voltage was improved by 15% for the devices fabricated on SOI substrates with a 10 µm-thick buried oxide. In the first experiment, the demonstration of ytterbium (174Yb+) ion trapping in the 2D hexagonal lattice trap is achieved with a relatively long lifetime of a laser-cooled ion up to 90 minutes and ≤ 5 minutes without cooling in ultra-high vacuum system. The 2D lattice trap design allows for reliable trapping of 2D ion lattices, rudimentary shuttling between lattice sites and deterministic introducing of defects into the ion lattice. Based on all these abilities, such a 2D lattice trap with the predicted reduction of lattice spacing down to 32 µm can be configured as a versatile architecture for 2D quantum simulations with trapped ions. In the second experiment, microparticle trapping in the 2D lattice trap, performed in air, is achieved with the longest trapping lifetime of 60 minutes. Both gold and aluminium-coated electrodes also lead to comparable trapping performances. Furthermore, the in situ levitation of microparticles is successfully demonstrated at the maximum levitation height of 30 µm. This ability provides additional control on the trapping height which increases the overall functionality of the 2D lattice trap.
An electroformed, three-dimensional stylus Paul trap was designed to confine a single atomic ion for use as a sensor to probe the electric-field noise of proximate surfaces. The trap was microfabricated with the UV-LIGA technique to reduce the distance of the ion from the surface of interest. We detail the fabrication process used to produce a 150 μm tall stylus trap with feature sizes of 40 μm. We confined single, laser-cooled, (25)Mg(+) ions with lifetimes greater than 2 h above the stylus trap in an ultra-high-vacuum environment. After cooling a motional mode of the ion at 4 MHz close to its ground state (<n> = 0.34 ± 0.07), the heating rate of the trap was measured with Raman sideband spectroscopy to be 387 ± 15 quanta/s at an ion height of 62 μm above the stylus electrodes.