Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/9909035

Quantum Logic Using Sympathetically Cooled Ions

D. Kielpinski, King, B. E., Christopher J. Myatt, Charles A. Sackett, Q. A. Turchette, Wayne M. Itano, Christopher R. Monroe, David J. Wineland, Wojciech Hubert Zurek

Published Sep 10, 1999• 3 citations
arXivHTMLPDF

Abstract

One limit to the fidelity of quantum logic operations on trapped ions arises from heating of the ions' collective modes of motion. Sympathetic cooling of the ions during the logic operations may eliminate this source of errors. We discuss benefits and drawbacks of this proposal, and describe possible experimental implementations. We also present an overview of trapped-ion dynamics in this scheme.

DOI
10.48550/arxiv.quant-ph/9909035

Related papers

Sympathetic cooling of trapped ions for quantum logic

D. Kielpinski, B. E. King, Christopher J. Myatt +6 more

One limit to the fidelity of quantum logic operations on trapped ions arises from heating of the ions' collective modes of motion. Sympathetic cooling of the ions during the logic operations may eliminate this source of errors. We discuss the benefits and drawbacks of this proposal, and describe possible experimental implementations. We also present an overview of trapped-ion dynamics in this scheme.

Physical Review A•Feb 16, 2000•149 citations

Sympathetic Cooling in Trapped Ions with Spectral Selectivity via the Zeeman Shift

Kavyashree Ranawat, Jiyong Yu, Andrew Van Horn +3 more

High-fidelity quantum logic operations in trapped ions often require the ions' collective motion to be cooled to near the ground state. Since cooling the ions' motion typically involves dissipative processes such as spontaneous photon scattering, sympathetic cooling is used on select coolant ions between gate sequences to cool the ion chain without affecting the data qubits. Common implementations for coolant ions include different atomic species, different isotopes of the same species or individually addressable ions. Each of these approaches have challenges associated with them, which include increased hardware complexity, reduced efficiency of radial mode cooling and re-ordering events which add additional experimental overhead. We demonstrate a sympathetic cooling scheme leveraging internal metastable atomic levels accessible via a narrow quadrupole transition, utilizing the natural Zeeman shift and individually addressed Raman transitions, to achieve isolation of the non-coolant or ``data ions" from coolant ions. We demonstrate modest decoherence of the data ions due to cooling, while preserving the coherence requirements for high-fidelity gate operations.

quant-pharXiv:2605.27577•May 28, 2026•0 citations

Ion-chain sympathetic cooling and gate dynamics

Aditya Paul, Crystal Noel

Sympathetic cooling is a technique often employed to mitigate motional heating in trapped-ion quantum computers. However, choosing system parameters such as number of coolants and cooling duty cycle for optimal gate performance requires evaluating trade-offs between motional errors and other slower errors such as qubit dephasing. The optimal parameters depend on cooling power, heating rate, and ion spacing in a particular system. In this study, we aim to analyze best practices for sympathetic cooling of long chains of trapped ions using analytical and computational methods. We use a case study to show that optimal cooling performance is achieved when coolants are placed at the center of the chain and provide a perturbative upper bound on the cooling limit of a mode given a particular set of cooling parameters. In addition, using computational tools, we analyze the trade-off between the number of coolant ions in a chain and the center-of-mass mode heating rate. We also show that cooling as often as possible when running a circuit is optimal when the qubit coherence time is otherwise long. These results provide a roadmap for how to choose sympathetic cooling parameters to maximize circuit performance in trapped-ion quantum computers using long chains of ions. Published by the American Physical Society 2024

arXiv:2405.13851•Physical Review Applied•Oct 15, 2024•1 citation

Collective Quantum Logic Spectroscopy

Raphael Kaubruegger, Matthew Patkowski, Yicheng Zhang +3 more

Scaling trapped-ion quantum sensors from single ions to large ensembles is a key challenge for next-generation precision measurements. At the same time, many ion species of interest for optical clocks and tests of fundamental physics lack closed cycling transitions required for direct laser cooling and state detection. Collective quantum logic spectroscopy addresses both limitations by coupling an ensemble of sensor, or spectroscopy, ions to one or more logic ions that provide sympathetic cooling and state readout. Here, we establish the fundamental performance limits and operating regimes of this protocol, identifying how the interaction strength, interrogation time, and logic-ensemble size govern sensitivity, dynamic range, and robustness to experimental imperfections. We show that quantum-limited sensitivity can be retained even with a single logic ion, while increasing the number of logic ions substantially improves readout efficiency and robustness. Beyond precision metrology, the same collective interface enables many-body measurements relevant to quantum information processing, including parity measurements and stabilizer-like syndrome extraction. Our results establish collective quantum logic spectroscopy as a scalable framework for optical clocks, quantum-enhanced sensing, and trapped-ion quantum information processing.

quant-pharXiv:2608.20471•Aug 24, 2026•0 citations

Simplified quantum logic with trapped ions

Christopher R. Monroe, Dietrich G. Leibfried, B. E. King +3 more

We describe a simplified scheme for quantum logic with a collection of laser-cooled trapped atomic ions. Building on the scheme of Cirac and Zoller, we show how the fundamental controlled-NOT gate between a collective mode of ion motion and the internal states of a single ion can be reduced to a single laser pulse, and the need for a third auxiliary internal electronic state can be eliminated.

arXiv:quant-ph/9612042•Physical Review A•Apr 1, 1997•116 citations

Sympathetic heating and cooling of trapped atomic and molecular ions

Craig R. Clark

Laser-cooled atomic ions have led to an unprecedented amount of control over the quantum states of matter. The Coulombic interaction allows for information to be transferred between neighboring ions, and this interaction can be used to entangle qubits for logic operations in quantum information processors. The same procedure for logic operations can be used for high resolution atomic spectroscopy, and is the basis for the most accurate atomic optical clocks to date. This thesis describes how laser-cooled atomic ions can impact physical chemistry through the development of molecular ion spectroscopy techniques and the simulation of magnetic systems by ion trap quantum computers. \n\t \n\tA new technique developed for spectroscopy, Sympathetic Heating Spectroscopy (SHS), takes advantage of the Coulombic interaction between two trapped ions: the control ion and a spectroscopy ion. SHS uses the back action of the interrogating laser to map spectroscopy ion information onto the Doppler shift of the control ion for measurement. SHS only requires Doppler cooling of the ions and fluorescence measurement and represents a simplification of quantum logic spectroscopy. This technique is demonstrated on two individual isotopes of calcium: Ca-40(+) for cooling and Ca-44(+) as the spectroscopy ion. \n \n\tHaving demonstrated SHS with atomic ions, the next step was to extend the technique by loading and characterizing molecular ions. The identification of an unknown molecular ion is necessary and can be achieved by monitoring the change in motion of the two ion crystal, which is dependent on the molecular ion mass. The motion of two trapped ions is described by their normal modes, which can be accurately measured by performing resolved sideband spectroscopy of the S(1/2)-D(5/2) transition of calcium. The resolved sidebands can be used to identify unknown ions (atomic and molecular) by calculating the mass based on the observed value in axial normal mode frequencies. Again, the trapped molecular ion is sympathetically cooled via the Coulombic interaction between the Ca-40(+) and the unknown molecular ion. The sensitivity of SHS could be improved by implementing sympathetic sideband cooling and determining the heating by measuring single quanta of motion. \n\t \n\tThe ultimate limit of control would be the development of an ion trap quantum computer. Many theoretical quantum computing researchers have made bold claims of the exponential improvement a quantum computer would have over a classical computer for the simulation of physical systems such as molecules. These claims are true in principle for ideal systems, but given non-ideal components it is necessary to consider the scaling due to error correction. An estimate of the resource requirements, the total number of physical qubits and computational time, required to compute the ground state energy of a 1-D quantum Transverse Ising Model (TIM) of N spin-1/2 particles, as a function of the system size and the numerical precision, is presented. This estimate is based on analyzing the impact of fault-tolerant quantum error correction in the context of the quantum logic array architecture. The results show that a significant amount of error correction is required to implement the TIM problem due to the exponential scaling of the computational time with the desired precision of the energy. Comparison of this result to the resource requirements for a fault-tolerant implementation of Shor's quantum factoring algorithm reveals that the required logical qubit reliability is similar for both the TIM problem and the factoring problem.

•Jan 6, 2012•0 citations
One limit to the fidelity of quantum logic operations on trapped ions arises from heating of the ions' collective modes of motion. Sympathetic cooling of the ions during the logic operations may eliminate this source of errors. We discuss benefits and drawbacks of this proposal, and describe possible experimental implementations. We also present an overview of trapped-ion dynamics in this scheme.
High-fidelity quantum logic operations in trapped ions often require the ions' collective motion to be cooled to near the ground state. Since cooling the ions' motion typically involves dissipative processes such as spontaneous photon scattering, sympathetic cooling is used on select coolant ions between gate sequences to cool the ion chain without affecting the data qubits. Common implementations for coolant ions include different atomic species, different isotopes of the same species or individually addressable ions. Each of these approaches have challenges associated with them, which include increased hardware complexity, reduced efficiency of radial mode cooling and re-ordering events which add additional experimental overhead. We demonstrate a sympathetic cooling scheme leveraging internal metastable atomic levels accessible via a narrow quadrupole transition, utilizing the natural Zeeman shift and individually addressed Raman transitions, to achieve isolation of the non-coolant or ``data ions" from coolant ions. We demonstrate modest decoherence of the data ions due to cooling, while preserving the coherence requirements for high-fidelity gate operations.
Sympathetic cooling is a technique often employed to mitigate motional heating in trapped-ion quantum computers. However, choosing system parameters such as number of coolants and cooling duty cycle for optimal gate performance requires evaluating trade-offs between motional errors and other slower errors such as qubit dephasing. The optimal parameters depend on cooling power, heating rate, and ion spacing in a particular system. In this study, we aim to analyze best practices for sympathetic cooling of long chains of trapped ions using analytical and computational methods. We use a case study to show that optimal cooling performance is achieved when coolants are placed at the center of the chain and provide a perturbative upper bound on the cooling limit of a mode given a particular set of cooling parameters. In addition, using computational tools, we analyze the trade-off between the number of coolant ions in a chain and the center-of-mass mode heating rate. We also show that cooling as often as possible when running a circuit is optimal when the qubit coherence time is otherwise long. These results provide a roadmap for how to choose sympathetic cooling parameters to maximize circuit performance in trapped-ion quantum computers using long chains of ions. Published by the American Physical Society 2024
Scaling trapped-ion quantum sensors from single ions to large ensembles is a key challenge for next-generation precision measurements. At the same time, many ion species of interest for optical clocks and tests of fundamental physics lack closed cycling transitions required for direct laser cooling and state detection. Collective quantum logic spectroscopy addresses both limitations by coupling an ensemble of sensor, or spectroscopy, ions to one or more logic ions that provide sympathetic cooling and state readout. Here, we establish the fundamental performance limits and operating regimes of this protocol, identifying how the interaction strength, interrogation time, and logic-ensemble size govern sensitivity, dynamic range, and robustness to experimental imperfections. We show that quantum-limited sensitivity can be retained even with a single logic ion, while increasing the number of logic ions substantially improves readout efficiency and robustness. Beyond precision metrology, the same collective interface enables many-body measurements relevant to quantum information processing, including parity measurements and stabilizer-like syndrome extraction. Our results establish collective quantum logic spectroscopy as a scalable framework for optical clocks, quantum-enhanced sensing, and trapped-ion quantum information processing.
Laser-cooled atomic ions have led to an unprecedented amount of control over the quantum states of matter. The Coulombic interaction allows for information to be transferred between neighboring ions, and this interaction can be used to entangle qubits for logic operations in quantum information processors. The same procedure for logic operations can be used for high resolution atomic spectroscopy, and is the basis for the most accurate atomic optical clocks to date. This thesis describes how laser-cooled atomic ions can impact physical chemistry through the development of molecular ion spectroscopy techniques and the simulation of magnetic systems by ion trap quantum computers. \n\t \n\tA new technique developed for spectroscopy, Sympathetic Heating Spectroscopy (SHS), takes advantage of the Coulombic interaction between two trapped ions: the control ion and a spectroscopy ion. SHS uses the back action of the interrogating laser to map spectroscopy ion information onto the Doppler shift of the control ion for measurement. SHS only requires Doppler cooling of the ions and fluorescence measurement and represents a simplification of quantum logic spectroscopy. This technique is demonstrated on two individual isotopes of calcium: Ca-40(+) for cooling and Ca-44(+) as the spectroscopy ion. \n \n\tHaving demonstrated SHS with atomic ions, the next step was to extend the technique by loading and characterizing molecular ions. The identification of an unknown molecular ion is necessary and can be achieved by monitoring the change in motion of the two ion crystal, which is dependent on the molecular ion mass. The motion of two trapped ions is described by their normal modes, which can be accurately measured by performing resolved sideband spectroscopy of the S(1/2)-D(5/2) transition of calcium. The resolved sidebands can be used to identify unknown ions (atomic and molecular) by calculating the mass based on the observed value in axial normal mode frequencies. Again, the trapped molecular ion is sympathetically cooled via the Coulombic interaction between the Ca-40(+) and the unknown molecular ion. The sensitivity of SHS could be improved by implementing sympathetic sideband cooling and determining the heating by measuring single quanta of motion. \n\t \n\tThe ultimate limit of control would be the development of an ion trap quantum computer. Many theoretical quantum computing researchers have made bold claims of the exponential improvement a quantum computer would have over a classical computer for the simulation of physical systems such as molecules. These claims are true in principle for ideal systems, but given non-ideal components it is necessary to consider the scaling due to error correction. An estimate of the resource requirements, the total number of physical qubits and computational time, required to compute the ground state energy of a 1-D quantum Transverse Ising Model (TIM) of N spin-1/2 particles, as a function of the system size and the numerical precision, is presented. This estimate is based on analyzing the impact of fault-tolerant quantum error correction in the context of the quantum logic array architecture. The results show that a significant amount of error correction is required to implement the TIM problem due to the exponential scaling of the computational time with the desired precision of the energy. Comparison of this result to the resource requirements for a fault-tolerant implementation of Shor's quantum factoring algorithm reveals that the required logical qubit reliability is similar for both the TIM problem and the factoring problem.