Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2608.20471

Collective Quantum Logic Spectroscopy

Raphael Kaubruegger, Matthew Patkowski, Yicheng Zhang, Robert J. Lewis-Swan, David B. Hume, Ana Maria Rey

quant-phphysics.atom-phSubmitted Aug 20, 2026• Announced Aug 24, 2026• 0 citations
arXivHTMLPDF

Abstract

Scaling trapped-ion quantum sensors from single ions to large ensembles is a key challenge for next-generation precision measurements. At the same time, many ion species of interest for optical clocks and tests of fundamental physics lack closed cycling transitions required for direct laser cooling and state detection. Collective quantum logic spectroscopy addresses both limitations by coupling an ensemble of sensor, or spectroscopy, ions to one or more logic ions that provide sympathetic cooling and state readout. Here, we establish the fundamental performance limits and operating regimes of this protocol, identifying how the interaction strength, interrogation time, and logic-ensemble size govern sensitivity, dynamic range, and robustness to experimental imperfections. We show that quantum-limited sensitivity can be retained even with a single logic ion, while increasing the number of logic ions substantially improves readout efficiency and robustness. Beyond precision metrology, the same collective interface enables many-body measurements relevant to quantum information processing, including parity measurements and stabilizer-like syndrome extraction. Our results establish collective quantum logic spectroscopy as a scalable framework for optical clocks, quantum-enhanced sensing, and trapped-ion quantum information processing.

Related papers

Scalable Quantum Logic Spectroscopy

Kaifeng Cui, Jose Valencia, Kevin T. Boyce +3 more

In quantum logic spectroscopy (QLS), one species of trapped ion is used as a sensor to detect the state of an otherwise inaccessible ion species. This extends precision measurements to a broader class of atomic and molecular systems for applications like atomic clocks and tests of fundamental physics. Here, we develop a new technique based on a Schrödinger cat interferometer to address the problem of scaling QLS to larger ion numbers. We demonstrate the basic features of this method using various combinations of ^{25}Mg^{+} logic ions and ^{27}Al^{+} spectroscopy ions. We observe higher detection efficiency by increasing the number of ^{25}Mg^{+} ions. Applied to multiple ^{27}Al^{+}, this method will improve the stability of high-accuracy optical clocks and could enable Heisenberg-limited QLS.

arXiv:2207.11768•Physical Review Letters•Nov 2, 2022•6 citations

Quantum Algorithmic Readout in Multi-Ion Clocks

Marius T. Schulte, Niels Lörch, Ian D. Leroux +2 more

Optical clocks based on ensembles of trapped ions promise record frequency accuracy with good short-term stability. Most suitable ion species lack closed transitions, so the clock signal must be read out indirectly by transferring the quantum state of the clock ions to cotrapped logic ions of a different species. Existing methods of quantum logic readout require a linear overhead in either time or the number of logic ions. Here we describe a quantum algorithmic readout whose overhead scales logarithmically with the number of clock ions in both of these respects. The scheme allows a quantum nondemolition readout of the number of excited clock ions using a single multispecies gate operation which can also be used in other areas of ion trap technology such as quantum information processing, quantum simulations, metrology, and precision spectroscopy.

arXiv:1501.06453•Physical Review Letters•Jan 8, 2016•31 citations

Spectroscopy Using Quantum Logic

Piet O. Schmidt, Till Rosenband, C. Langer +3 more

We present a general technique for precision spectroscopy of atoms that lack suitable transitions for efficient laser cooling, internal state preparation, and detection. In our implementation with trapped atomic ions, an auxiliary "logic" ion provides sympathetic laser cooling, state initialization, and detection for a simultaneously trapped "spectroscopy" ion. Detection is achieved by applying a mapping operation to each ion, which results in a coherent transfer of the spectroscopy ion's internal state onto the logic ion, where it is then measured with high efficiency. Experimental realization, by using 9Be+ as the logic ion and 27Al+ as the spectroscopy ion, indicates the feasibility of applying this technique to make accurate optical clocks based on single ions.

Science•Jul 28, 2005•642 citations

Quantum Logic Spectroscopy with Ions in Thermal Motion

Daniel Kienzler, Y. Wan, Stephen D. Erickson +4 more

A mixed-species geometric phase gate has been proposed for implementing quantum logic spectroscopy on trapped ions, which combines probe and information transfer from the spectroscopy to the logic ion in a single pulse. We experimentally realize this method, show how it can be applied as a technique for identifying transitions in currently intractable atoms or molecules, demonstrate its reduced temperature sensitivity, and observe quantum-enhanced frequency sensitivity when it is applied to multi-ion chains. Potential applications include improved readout of trapped-ion clocks and simplified error syndrome measurements for quantum error correction.

arXiv:1905.02388•Physical Review X•Apr 16, 2020•5 citations

Integrated optical multi-ion quantum logic

Karan K. Mehta, Chi Zhang, Maciej Malinowski +3 more

Abstract Practical and useful quantum information processing requires substantial improvements with respect to current systems, both in the error rates of basic operations and in scale. The fundamental qualities of individual trapped-ion1 qubits are promising for long-term systems2, but the optics involved in their precise control are a barrier to scaling3. Planar-fabricated optics integrated within ion-trap devices can make such systems simultaneously more robust and parallelizable, as suggested by previous work with single ions4. Here we use scalable optics co-fabricated with a surface-electrode ion trap to achieve high-fidelity multi-ion quantum logic gates, which are often the limiting elements in building up the precise, large-scale entanglement that is essential to quantum computation. Light is efficiently delivered to a trap chip in a cryogenic environment via direct fibre coupling on multiple channels, eliminating the need for beam alignment into vacuum systems and cryostats and lending robustness to vibrations and beam-pointing drifts. This allows us to perform ground-state laser cooling of ion motion and to implement gates generating two-ion entangled states with fidelities greater than 99.3(2) per cent. This work demonstrates hardware that reduces noise and drifts in sensitive quantum logic, and simultaneously offers a route to practical parallelization for high-fidelity quantum processors5. Similar devices may also find applications in atom- and ion-based quantum sensing and timekeeping6.

•Jan 1, 2020•249 citations

Quantum Logic Spectroscopy of Highly Charged Ions

P. Micke

Fundamental interactions and symmetries define the structure and properties of all matter, in particular of its small and diverse visible constituents—the atoms. The study of their distinctive spectra through precision spectroscopy is therefore a vital tool to advance our understanding of nature. Highly charged ions (HCIs) constitute the largest fraction of all atoms since every atom has as many charge states as electrons it can bind. Although most of the matter on Earth is neutral, HCIs are ubiquitous in the universe and their systematic study is essential not only for atomic physics but eminently for astrophysics, nuclear physics, and fusion research, among others. Recently, HCIs have been identified as ideal candidates for sensitive tests of physics beyond the Standard Model of particle physics and for use in future high-accuracy optical atomic clocks. However, the realization of such proposals has been hindered by the hitherto constrained laboratory control and limited spectroscopic accuracy of about parts-per-million fractional uncertainty levels. This thesis reports the first coherent laser spectroscopy of HCIs, boosting the achievable spectroscopic precision by eight orders of magnitude compared to traditional spectroscopy methods. The 2P1/2–2P3/2 fine-structure ground-state transition in highly charged 40Ar13+ at an optical wavelength of 441 nm was chosen as a proof-of-principle case. A single ion of this species was isolated from a megakelvin-hot plasma cloud and co-trapped together with a laser-cooled singly charged 9Be+ ion in a two-ion crystal, confined in the harmonic potential of a cryogenic linear Paul trap. This coupled quantum-mechanical system was then cooled to its ground state of axial motion, corresponding to the lowest temperature of a HCI ever achieved. The spectroscopy was realized by implementing quantum logic techniques which allow preparation of the quantum state of the HCI and to map its electronic state after spectroscopy onto the 9Be+ logic ion in order to detect it there with high efficiency through electron shelving. In addition to the increase of spectroscopic precision, the excited-state lifetime and g-factor were measured—the latter one to unprecedented accuracy, resolving effects from special relativity, interelectronic interactions, and quantum electrodynamics. Moreover, it settled a discrepancy between theoretical predictions. The demonstrated techniques are not limited to the specific 40Ar13+ species but universally applicable to other HCIs. Thereby, this work unlocks the potential of HCIs for unrivaled tests of fundamental physics, the search for new physics—such as a 5th force, variations of fundamental constants and dark matter candidates—as well as the use of HCIs in novel optical atomic clocks.

•Jan 1, 2020•1 citation
Scaling trapped-ion quantum sensors from single ions to large ensembles is a key challenge for next-generation precision measurements. At the same time, many ion species of interest for optical clocks and tests of fundamental physics lack closed cycling transitions required for direct laser cooling and state detection. Collective quantum logic spectroscopy addresses both limitations by coupling an ensemble of sensor, or spectroscopy, ions to one or more logic ions that provide sympathetic cooling and state readout. Here, we establish the fundamental performance limits and operating regimes of this protocol, identifying how the interaction strength, interrogation time, and logic-ensemble size govern sensitivity, dynamic range, and robustness to experimental imperfections. We show that quantum-limited sensitivity can be retained even with a single logic ion, while increasing the number of logic ions substantially improves readout efficiency and robustness. Beyond precision metrology, the same collective interface enables many-body measurements relevant to quantum information processing, including parity measurements and stabilizer-like syndrome extraction. Our results establish collective quantum logic spectroscopy as a scalable framework for optical clocks, quantum-enhanced sensing, and trapped-ion quantum information processing.
In quantum logic spectroscopy (QLS), one species of trapped ion is used as a sensor to detect the state of an otherwise inaccessible ion species. This extends precision measurements to a broader class of atomic and molecular systems for applications like atomic clocks and tests of fundamental physics. Here, we develop a new technique based on a Schrödinger cat interferometer to address the problem of scaling QLS to larger ion numbers. We demonstrate the basic features of this method using various combinations of ^{25}Mg^{+} logic ions and ^{27}Al^{+} spectroscopy ions. We observe higher detection efficiency by increasing the number of ^{25}Mg^{+} ions. Applied to multiple ^{27}Al^{+}, this method will improve the stability of high-accuracy optical clocks and could enable Heisenberg-limited QLS.
Optical clocks based on ensembles of trapped ions promise record frequency accuracy with good short-term stability. Most suitable ion species lack closed transitions, so the clock signal must be read out indirectly by transferring the quantum state of the clock ions to cotrapped logic ions of a different species. Existing methods of quantum logic readout require a linear overhead in either time or the number of logic ions. Here we describe a quantum algorithmic readout whose overhead scales logarithmically with the number of clock ions in both of these respects. The scheme allows a quantum nondemolition readout of the number of excited clock ions using a single multispecies gate operation which can also be used in other areas of ion trap technology such as quantum information processing, quantum simulations, metrology, and precision spectroscopy.
We present a general technique for precision spectroscopy of atoms that lack suitable transitions for efficient laser cooling, internal state preparation, and detection. In our implementation with trapped atomic ions, an auxiliary "logic" ion provides sympathetic laser cooling, state initialization, and detection for a simultaneously trapped "spectroscopy" ion. Detection is achieved by applying a mapping operation to each ion, which results in a coherent transfer of the spectroscopy ion's internal state onto the logic ion, where it is then measured with high efficiency. Experimental realization, by using 9Be+ as the logic ion and 27Al+ as the spectroscopy ion, indicates the feasibility of applying this technique to make accurate optical clocks based on single ions.
A mixed-species geometric phase gate has been proposed for implementing quantum logic spectroscopy on trapped ions, which combines probe and information transfer from the spectroscopy to the logic ion in a single pulse. We experimentally realize this method, show how it can be applied as a technique for identifying transitions in currently intractable atoms or molecules, demonstrate its reduced temperature sensitivity, and observe quantum-enhanced frequency sensitivity when it is applied to multi-ion chains. Potential applications include improved readout of trapped-ion clocks and simplified error syndrome measurements for quantum error correction.
Abstract Practical and useful quantum information processing requires substantial improvements with respect to current systems, both in the error rates of basic operations and in scale. The fundamental qualities of individual trapped-ion1 qubits are promising for long-term systems2, but the optics involved in their precise control are a barrier to scaling3. Planar-fabricated optics integrated within ion-trap devices can make such systems simultaneously more robust and parallelizable, as suggested by previous work with single ions4. Here we use scalable optics co-fabricated with a surface-electrode ion trap to achieve high-fidelity multi-ion quantum logic gates, which are often the limiting elements in building up the precise, large-scale entanglement that is essential to quantum computation. Light is efficiently delivered to a trap chip in a cryogenic environment via direct fibre coupling on multiple channels, eliminating the need for beam alignment into vacuum systems and cryostats and lending robustness to vibrations and beam-pointing drifts. This allows us to perform ground-state laser cooling of ion motion and to implement gates generating two-ion entangled states with fidelities greater than 99.3(2) per cent. This work demonstrates hardware that reduces noise and drifts in sensitive quantum logic, and simultaneously offers a route to practical parallelization for high-fidelity quantum processors5. Similar devices may also find applications in atom- and ion-based quantum sensing and timekeeping6.
Fundamental interactions and symmetries define the structure and properties of all matter, in particular of its small and diverse visible constituents—the atoms. The study of their distinctive spectra through precision spectroscopy is therefore a vital tool to advance our understanding of nature. Highly charged ions (HCIs) constitute the largest fraction of all atoms since every atom has as many charge states as electrons it can bind. Although most of the matter on Earth is neutral, HCIs are ubiquitous in the universe and their systematic study is essential not only for atomic physics but eminently for astrophysics, nuclear physics, and fusion research, among others. Recently, HCIs have been identified as ideal candidates for sensitive tests of physics beyond the Standard Model of particle physics and for use in future high-accuracy optical atomic clocks. However, the realization of such proposals has been hindered by the hitherto constrained laboratory control and limited spectroscopic accuracy of about parts-per-million fractional uncertainty levels. This thesis reports the first coherent laser spectroscopy of HCIs, boosting the achievable spectroscopic precision by eight orders of magnitude compared to traditional spectroscopy methods. The 2P1/2–2P3/2 fine-structure ground-state transition in highly charged 40Ar13+ at an optical wavelength of 441 nm was chosen as a proof-of-principle case. A single ion of this species was isolated from a megakelvin-hot plasma cloud and co-trapped together with a laser-cooled singly charged 9Be+ ion in a two-ion crystal, confined in the harmonic potential of a cryogenic linear Paul trap. This coupled quantum-mechanical system was then cooled to its ground state of axial motion, corresponding to the lowest temperature of a HCI ever achieved. The spectroscopy was realized by implementing quantum logic techniques which allow preparation of the quantum state of the HCI and to map its electronic state after spectroscopy onto the 9Be+ logic ion in order to detect it there with high efficiency through electron shelving. In addition to the increase of spectroscopic precision, the excited-state lifetime and g-factor were measured—the latter one to unprecedented accuracy, resolving effects from special relativity, interelectronic interactions, and quantum electrodynamics. Moreover, it settled a discrepancy between theoretical predictions. The demonstrated techniques are not limited to the specific 40Ar13+ species but universally applicable to other HCIs. Thereby, this work unlocks the potential of HCIs for unrivaled tests of fundamental physics, the search for new physics—such as a 5th force, variations of fundamental constants and dark matter candidates—as well as the use of HCIs in novel optical atomic clocks.