Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1501.06453 · Physical Review Letters

Quantum Algorithmic Readout in Multi-Ion Clocks

Marius T. Schulte, Niels Lörch, Ian D. Leroux, Piet O. Schmidt, Klemens Hammerer

Published Jan 8, 2016• 31 citations
arXivHTMLPDF

Abstract

Optical clocks based on ensembles of trapped ions promise record frequency accuracy with good short-term stability. Most suitable ion species lack closed transitions, so the clock signal must be read out indirectly by transferring the quantum state of the clock ions to cotrapped logic ions of a different species. Existing methods of quantum logic readout require a linear overhead in either time or the number of logic ions. Here we describe a quantum algorithmic readout whose overhead scales logarithmically with the number of clock ions in both of these respects. The scheme allows a quantum nondemolition readout of the number of excited clock ions using a single multispecies gate operation which can also be used in other areas of ion trap technology such as quantum information processing, quantum simulations, metrology, and precision spectroscopy.

DOI
10.1103/physrevlett.116.013002

Related papers

Collective Quantum Logic Spectroscopy

Raphael Kaubruegger, Matthew Patkowski, Yicheng Zhang +3 more

Scaling trapped-ion quantum sensors from single ions to large ensembles is a key challenge for next-generation precision measurements. At the same time, many ion species of interest for optical clocks and tests of fundamental physics lack closed cycling transitions required for direct laser cooling and state detection. Collective quantum logic spectroscopy addresses both limitations by coupling an ensemble of sensor, or spectroscopy, ions to one or more logic ions that provide sympathetic cooling and state readout. Here, we establish the fundamental performance limits and operating regimes of this protocol, identifying how the interaction strength, interrogation time, and logic-ensemble size govern sensitivity, dynamic range, and robustness to experimental imperfections. We show that quantum-limited sensitivity can be retained even with a single logic ion, while increasing the number of logic ions substantially improves readout efficiency and robustness. Beyond precision metrology, the same collective interface enables many-body measurements relevant to quantum information processing, including parity measurements and stabilizer-like syndrome extraction. Our results establish collective quantum logic spectroscopy as a scalable framework for optical clocks, quantum-enhanced sensing, and trapped-ion quantum information processing.

quant-pharXiv:2608.20471•Aug 24, 2026•0 citations

Scalable Quantum Logic Spectroscopy

Kaifeng Cui, Jose Valencia, Kevin T. Boyce +3 more

In quantum logic spectroscopy (QLS), one species of trapped ion is used as a sensor to detect the state of an otherwise inaccessible ion species. This extends precision measurements to a broader class of atomic and molecular systems for applications like atomic clocks and tests of fundamental physics. Here, we develop a new technique based on a Schrödinger cat interferometer to address the problem of scaling QLS to larger ion numbers. We demonstrate the basic features of this method using various combinations of ^{25}Mg^{+} logic ions and ^{27}Al^{+} spectroscopy ions. We observe higher detection efficiency by increasing the number of ^{25}Mg^{+} ions. Applied to multiple ^{27}Al^{+}, this method will improve the stability of high-accuracy optical clocks and could enable Heisenberg-limited QLS.

arXiv:2207.11768•Physical Review Letters•Nov 2, 2022•6 citations

Quantum Logic Spectroscopy with Ions in Thermal Motion

Daniel Kienzler, Y. Wan, Stephen D. Erickson +4 more

A mixed-species geometric phase gate has been proposed for implementing quantum logic spectroscopy on trapped ions, which combines probe and information transfer from the spectroscopy to the logic ion in a single pulse. We experimentally realize this method, show how it can be applied as a technique for identifying transitions in currently intractable atoms or molecules, demonstrate its reduced temperature sensitivity, and observe quantum-enhanced frequency sensitivity when it is applied to multi-ion chains. Potential applications include improved readout of trapped-ion clocks and simplified error syndrome measurements for quantum error correction.

arXiv:1905.02388•Physical Review X•Apr 16, 2020•5 citations

Single-Ion Optical Clock Based on Quantum Logic Spectroscopy

Kazuhiro Hayasaka

This paper presents an overview of the Al+ optical clock, which is based on quantum logic spectroscopy and provides the most accurate frequency measurement ever reported. Dehmelt’s original design of the optical clock was not realized due to the difficulty in generating the vacuum ultraviolet radiation necessary for laser cooling and the ion’s quantum state detection. The problem was solved by sympathetically cooling the ion with another ion and detecting the quantum state using the ancillary ion. The method, which is called quantum logic spectroscopy, comes from the use of phonon qubit as a bus of the quantum state of the ions in the Cirac-Zoller ion-trap quantum computer. The clock can be simplifi ed by introducing direct excitation by vacuum ultraviolet radiation or another ion species. The clock’s stability will be improved more than ten times by a middle-term stabilized clock laser.

The Review of Laser Engineering•Jan 1, 2013•1 citation

Spectroscopy Using Quantum Logic

Piet O. Schmidt, Till Rosenband, C. Langer +3 more

We present a general technique for precision spectroscopy of atoms that lack suitable transitions for efficient laser cooling, internal state preparation, and detection. In our implementation with trapped atomic ions, an auxiliary "logic" ion provides sympathetic laser cooling, state initialization, and detection for a simultaneously trapped "spectroscopy" ion. Detection is achieved by applying a mapping operation to each ion, which results in a coherent transfer of the spectroscopy ion's internal state onto the logic ion, where it is then measured with high efficiency. Experimental realization, by using 9Be+ as the logic ion and 27Al+ as the spectroscopy ion, indicates the feasibility of applying this technique to make accurate optical clocks based on single ions.

Science•Jul 28, 2005•642 citations

A multi-ion optical clock with $\mathbf{5 \times 10^{-19}}$ uncertainty

Melina Filzinger, Martin R. Steinel, Jian Jiang +4 more

Today's most accurate clocks are based on laser spectroscopy of electronic transitions in single trapped ions and feature fractional frequency uncertainties below $1\times10^{-18}$. Scaling these systems to multiple, simultaneously interrogated ions reduces measurement times, driving recent advances in multi-ion clocks. However, maintaining state-of-the-art systematic uncertainties while increasing the number of ions remains a central challenge. Here, we report on a multi-ion optical atomic clock with a fractional frequency uncertainty of $5.3\times10^{-19}$ and up to 10 \Sr ions. Ion-resolved state detection enables minimization of position-dependent shifts, with residual effects suppressed below the $10^{-20}$-level. Clock operation with eight to ten ions reduces the measurement time by a factor of 4.8 compared to single-ion operation. A comparison with an established \Yb single-ion clock yields an unperturbed frequency ratio of $0.6926711632159660405(20)$, with a statistical uncertainty of $0.9\times10^{-18}$ and a combined uncertainty of $2.9\times 10^{-18}$. These results demonstrate robust multi-ion clock operation with reduced averaging time and state-of-the-art accuracy.

physics.atom-phCross-listedarXiv:2603.23446•Mar 25, 2026•0 citations
Optical clocks based on ensembles of trapped ions promise record frequency accuracy with good short-term stability. Most suitable ion species lack closed transitions, so the clock signal must be read out indirectly by transferring the quantum state of the clock ions to cotrapped logic ions of a different species. Existing methods of quantum logic readout require a linear overhead in either time or the number of logic ions. Here we describe a quantum algorithmic readout whose overhead scales logarithmically with the number of clock ions in both of these respects. The scheme allows a quantum nondemolition readout of the number of excited clock ions using a single multispecies gate operation which can also be used in other areas of ion trap technology such as quantum information processing, quantum simulations, metrology, and precision spectroscopy.
Scaling trapped-ion quantum sensors from single ions to large ensembles is a key challenge for next-generation precision measurements. At the same time, many ion species of interest for optical clocks and tests of fundamental physics lack closed cycling transitions required for direct laser cooling and state detection. Collective quantum logic spectroscopy addresses both limitations by coupling an ensemble of sensor, or spectroscopy, ions to one or more logic ions that provide sympathetic cooling and state readout. Here, we establish the fundamental performance limits and operating regimes of this protocol, identifying how the interaction strength, interrogation time, and logic-ensemble size govern sensitivity, dynamic range, and robustness to experimental imperfections. We show that quantum-limited sensitivity can be retained even with a single logic ion, while increasing the number of logic ions substantially improves readout efficiency and robustness. Beyond precision metrology, the same collective interface enables many-body measurements relevant to quantum information processing, including parity measurements and stabilizer-like syndrome extraction. Our results establish collective quantum logic spectroscopy as a scalable framework for optical clocks, quantum-enhanced sensing, and trapped-ion quantum information processing.
In quantum logic spectroscopy (QLS), one species of trapped ion is used as a sensor to detect the state of an otherwise inaccessible ion species. This extends precision measurements to a broader class of atomic and molecular systems for applications like atomic clocks and tests of fundamental physics. Here, we develop a new technique based on a Schrödinger cat interferometer to address the problem of scaling QLS to larger ion numbers. We demonstrate the basic features of this method using various combinations of ^{25}Mg^{+} logic ions and ^{27}Al^{+} spectroscopy ions. We observe higher detection efficiency by increasing the number of ^{25}Mg^{+} ions. Applied to multiple ^{27}Al^{+}, this method will improve the stability of high-accuracy optical clocks and could enable Heisenberg-limited QLS.
A mixed-species geometric phase gate has been proposed for implementing quantum logic spectroscopy on trapped ions, which combines probe and information transfer from the spectroscopy to the logic ion in a single pulse. We experimentally realize this method, show how it can be applied as a technique for identifying transitions in currently intractable atoms or molecules, demonstrate its reduced temperature sensitivity, and observe quantum-enhanced frequency sensitivity when it is applied to multi-ion chains. Potential applications include improved readout of trapped-ion clocks and simplified error syndrome measurements for quantum error correction.
This paper presents an overview of the Al+ optical clock, which is based on quantum logic spectroscopy and provides the most accurate frequency measurement ever reported. Dehmelt’s original design of the optical clock was not realized due to the difficulty in generating the vacuum ultraviolet radiation necessary for laser cooling and the ion’s quantum state detection. The problem was solved by sympathetically cooling the ion with another ion and detecting the quantum state using the ancillary ion. The method, which is called quantum logic spectroscopy, comes from the use of phonon qubit as a bus of the quantum state of the ions in the Cirac-Zoller ion-trap quantum computer. The clock can be simplifi ed by introducing direct excitation by vacuum ultraviolet radiation or another ion species. The clock’s stability will be improved more than ten times by a middle-term stabilized clock laser.
We present a general technique for precision spectroscopy of atoms that lack suitable transitions for efficient laser cooling, internal state preparation, and detection. In our implementation with trapped atomic ions, an auxiliary "logic" ion provides sympathetic laser cooling, state initialization, and detection for a simultaneously trapped "spectroscopy" ion. Detection is achieved by applying a mapping operation to each ion, which results in a coherent transfer of the spectroscopy ion's internal state onto the logic ion, where it is then measured with high efficiency. Experimental realization, by using 9Be+ as the logic ion and 27Al+ as the spectroscopy ion, indicates the feasibility of applying this technique to make accurate optical clocks based on single ions.
A multi-ion optical clock with 5×10−19\mathbf{5 \times 10^{-19}}5×10−19 uncertainty
Today's most accurate clocks are based on laser spectroscopy of electronic transitions in single trapped ions and feature fractional frequency uncertainties below 1×10−181\times10^{-18}1×10−18. Scaling these systems to multiple, simultaneously interrogated ions reduces measurement times, driving recent advances in multi-ion clocks. However, maintaining state-of-the-art systematic uncertainties while increasing the number of ions remains a central challenge. Here, we report on a multi-ion optical atomic clock with a fractional frequency uncertainty of 5.3×10−195.3\times10^{-19}5.3×10−19 and up to 10 \Sr ions. Ion-resolved state detection enables minimization of position-dependent shifts, with residual effects suppressed below the 10−2010^{-20}10−20-level. Clock operation with eight to ten ions reduces the measurement time by a factor of 4.8 compared to single-ion operation. A comparison with an established \Yb single-ion clock yields an unperturbed frequency ratio of 0.6926711632159660405(20)0.6926711632159660405(20)0.6926711632159660405(20), with a statistical uncertainty of 0.9×10−180.9\times10^{-18}0.9×10−18 and a combined uncertainty of 2.9×10−182.9\times 10^{-18}2.9×10−18. These results demonstrate robust multi-ion clock operation with reduced averaging time and state-of-the-art accuracy.